• Title/Summary/Keyword: thermal management system

Search Result 387, Processing Time 0.033 seconds

Development of 80kW Bi-directional Hybrid-SiC Boost-Buck Converter using Droop Control in DC Nano-grid (DC 나노그리드에서 Droop제어를 적용한 80kW급 양방향 하이브리드-SiC 부스트-벅 컨버터 개발)

  • Kim, Yeon-Woo;Kwon, Min-Ho;Park, Sung-Youl;Kim, Min-Kook;Yang, Dae-Ki;Choi, Se-Wan;Oh, Seong-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.360-368
    • /
    • 2017
  • This paper proposes the 80-kW high-efficiency bidirectional hybrid SiC boost/buck converter using droop control for DC nano-grid. The proposed converter consists of four 20-kW modules to achieve fault tolerance, ease of thermal management, and reduced component stress. Each module is constructed as a cascaded structure of the two basic bi-directional converters, namely, interleaved boost and buck converters. A six-pack hybrid SiC intelligent power module (IPM) suitable for the proposed cascaded structure is adopted for high-efficiency and compactness. The proposed converter with hybrid switching method reduces the switching loss by minimizing switching of insulated gate bipolar transistor (IGBT). Each module control achieves smooth transfer from buck to boost operation and vice versa, since current controller switchover is not necessary. Furthermore, the proposed parallel control using DC droop with secondary control, enhances the current sharing accuracy while well regulating the DC bus voltage. A 20-kW prototype of the proposed converter has been developed and verified with experiments and indicates a 99.3% maximum efficiency and 98.8% rated efficiency.

Evaluation of Body Movement during Sleep with a Thermopile, Wavelets and Neuro-fuzzy Reasoning

  • Yoon, Young-Ro;Shin, Jae-Woo;Lee, Hyun-Sook;Jose C.Principe
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.5-10
    • /
    • 2004
  • Body movement is one of the important factors in sleep analysis. In this study, a thermopile detector with four channels was implemented as a non-contacting detector of body movement in sleep. Using a thermopile mathematical model and several frames of thermal images, the possibility of detecting body movement was evaluated. Instant body movement signals were evaluated for the upper, lower, and entire body using the Haar wavelet. This decomposition shows the points in time when the upper-body or lower-body movement occurred and the level of body movement. Additionally, partial body movement was decomposed in head-only, whole body, and leg-only movement using the ANFIS algorithm. Finally, three subject's data were evaluated for 60 minutes, and the detection rates of instant and partial body movement, on average, were 96.3% and 89.2%, respectively.

Performance Analysis of Off-Gas/Syngas Combustor for Thermal Management of High Temperature Fuel Cell System (고온형 연료전지 열관리를 위한 배기가스 연소기 성능시험)

  • Lee, Sang-Min;Lee, Youn-Hwa;Ahn, Kook-Young;Yu, Sang-Seok
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.193-200
    • /
    • 2010
  • Anode off-gas of high temperature fuel cell still contains combustible components such as hydrogen, carbon monoxide and hydrocarbon. In this study, a catalytic combustor has been applied to the high temperature fuel cell so that the combustion of anode-off gas can be boosted up. Since the performance of catalytic combustor directly depends on the combustion catalyst, this study is designed to perform the experimental investigation on the combustion characteristics of the three commercial catalysts with a different composition. Screening tests with three catalysts are preceded before the performance examination since it is necessary to determine the most suitable catalyst for design configuration of the catalytic combustor. The performance analysis shows that methane conversion rate strongly depends on gas hourly space velocity (GHSV) as well as inlet gas temperature. Additionally, the GSHV optimization results show that the optimum GHSV will be in the range between 18,000 $hr^{-1}$ and 36,000 $hr^{-1}$. It is also shown that the minimum inlet temperature of catalytic reaction of methane is from $100^{\circ}C$ to $150^{\circ}C$.

Numerical Study on the Heat Transfer Characteristics of 360 Wh Li-ion Battery Pack for Personal Mobility (360 Wh급 퍼스널 모빌리티용 리튬이온 배터리 팩의 열전달 특성에 관한 연구)

  • Kim, Dae-Wan;Seo, Jae-Hyeong;Kim, Hak-Min;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.1-7
    • /
    • 2017
  • This study numerically evaluates the heat transfer characteristics of a 360-Wh Li-ion battery pack. The analysis was done in ANSYS CFX using different cell arrangements, cell holders, and case materials for a personal mobility device program. A total of four cases of cell arrangements were considered, along with various materials for both the cell holder and the case, such as polypropylene, aluminum, and magnesium alloy. Out of the four cell arrangements, model 2 showed the best heat transfer performance, while aluminum showed the best heat transfer performance for the cell holder and case.

Review on the Effectiveness of Apartments According to Insulation Reinforcement of Energy Saving Design Standard - Energy Cost Analysis of Space Heating and Domestic Hot Water - (에너지절약설계기준의 단열 변화에 따른 공동주택 실효성 검토 - 난방 및 급탕에너지 사용금액 분석 -)

  • Kim, Ji-hyeon;Lim, Hee-won;Lee, Hyun-seung;Shin, U-cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.173-178
    • /
    • 2020
  • In this study, we analyzed space heating and domestic hot water(DHW) charges from 2017 to 2018 for 151,206 households in 202 apartment complexes built from 1997 to 2016, in order to evaluate the effectiveness of Korea's insulation standards reinforcement. The applied insulation standards were revised three times(in 1987, 2001 and 2010). We used the Anderson-Darling test to review the normality of the space heating and DHW charges. As a result, each p-value was greater than 0.05 and it followed the normal distribution. The annual average space heating charges per unit area of apartments with the 1987 insulation standards were 5,237₩/㎡a in 2017 and 5,328₩/㎡a in 2018. The heating charges with the 2001 standards were 4,827₩/㎡a in 2017 and 4,817₩/㎡a in 2018. Compared to previous standards(1987 standards), heating charges decreased by 7.8% and 9.6%. Also the heating charges with the 2010 standards were 3,683₩/㎡a in 2017 and 3,734₩/㎡a in 2018. Compared to previous standards(2001 standards), heating charges decreased by 24.3% and 21.5%. On the other hand, compared to each previous standards, DHW charges were decreased by 12.2%, 13.6% or increased by 4.6%, 6.9%, which means there's no correlation between insulation standards reinforcement and DHW charges.

Evapotranspirations of Lettuce and Cucumber by Cropping Systems in Greenhouse (시설재배 상추 및 오이의 재배방식별 증발산량)

  • 남상운;이남호;전우정;황한철;홍성구;허연정
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.168-175
    • /
    • 1997
  • In greenhouse, data on evapotranspiration or water consumption is important for the rational water management, irrigation planning, thermal environment analysis, and watering automation. But little investigations have been attempted to make clear the characteristics of water consumption in greenhouse. In this paper, evapotransplrations of lettuce and cucumber by cropping systems were investigated. And the correlations among evapotranspiration, pan evaporation, solar radiation, mean air temperature, and minimum relative humidity were analyzed. Experimental cropping systems of lettuce were soil culture and NFT system. Those of cucumber were soil culture, perlite culture, and rockwool culture. Total water consumption of lettuce was 2.62$\ell$/plant in soil culture and 1.71$\ell$/plant in NFT system. That of cucumber was 45.22$\ell$/plant in soil culture, 27.45$\ell$/plant in rockwool culture and 29.06$\ell$/plant in perlite culture. Therefore total water consumption of soil culture showed higher than soilless culture.

  • PDF

Diagnosis of Conflict Problem between the Marine Environmental Conservation and Development, and Policy Implication for Marine Spatial Planning (해양환경보전과 이용·개발의 상충 분석과 해양공간계획에 대한 시사점)

  • Lee, Dae In;Tac, Dae Ho;Kim, Gui Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.3
    • /
    • pp.227-235
    • /
    • 2016
  • This paper emphasized the necessity of the marine spatial planning (MSP) through the analysis of the major developmental projects which could make a contradiction based on the adequacy of the site selection and environmental impacts. The conflicting affairs between space utilization and management plan happen in the following ways: marine renewable energy development, sand mining, reclamation, construction of golf course in coastal area, thermal effluent and waste heat, erosion causing port development. The conflict of stakeholder continues caused by the accumulated environmental impact. For the reasons mentioned above, we found two things. First, it is necessary to comprehend the fact of developmental planning and MSP. Second, it is still unsatisfactory to connect the relevance of laws related to the spatial planning. For the reinforcement of marine environmental policy management, it is necessary to consolidate the property of site selection and assessment of developmental scale. Especially, while the strategic environmental assessment is in progress based on site selection and property of scale, consistent diagnosis is needed in the following concerns: the fact of the marine spatial planning, the relevance between national developmental plan and regional developmental plan, fisheries regulation, marine protected animals. For the environmentally sound and sustainable development (ESSD), MSP should have to be prepared based in a way of top-down including coastal and EEZ plan, relevance of ocean-use zoning and sector planning, 3-D spatial information. And also integrated information system have to be prepared through high-tech marine spatial information. In conclusion, consistent and relevant strategy for MSP should have to include the whole information related to the maritime affairs such as harbor, fishing port, fishing ground, coastal management, marine ecosystem generally.

3D Modeling of Turbid Density Flow Induced into Daecheong Reservoir with ELCOM-CAEDYM (ELCOM-CAEDYM을 이용한 대청댐 유입탁수의 3차원 모델링)

  • Chung, Se-Woong;Lee, Heung-Soo;Ryoo, Jae-Il;Ryu, In-Gu;Oh, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.12
    • /
    • pp.1187-1198
    • /
    • 2008
  • Many reservoirs in Korea and their downstream environments are under increased pressure for water utilization and ecosystem management from longer discharge of turbid flood runoff compared to a natural river system. Turbidity($C_T$) is an indirect measurement of water 'cloudiness' and has been widely used as an important indicator of water quality and environmental "health". However, $C_T$ modeling studies have been rare due to lack of experimental data that are necessary for model validation. The objective of this study is to validate a coupled three-dimensional(3D) hydrodynamic and particle dynamics model (ELCOM-CAEDYM) for the simulation of turbid density flows in stratified Daecheong Reservoir using extensive field data. Three different groups of suspended solids (SS) classified by the particle size were used as model state variables, and their site-specific SS-$C_T$ relationships were used for the conversion between field measurements ($C_T$) and state variables (SS). The simulation results were validated by comparing vertical profiles of temperature and turbidity measured at monitoring stations of Haenam(R3) and Dam(R4) in 2004. The model showed good performance in reproducing the reservoir thermal structure and propagation of stream density flow, and the magnitude and distribution of turbidity in the reservoir were consistent with the field data. The 3D model and turbidity modeling framework suggested in this study can be used as a supportive tool for the best management of turbidity flow in other reservoirs that have similar turbidity problems.

A Study on the Integrated Management System of Municipal Solid Waste from Seoul Metropolitan City (서울시 일반폐기물의 통합적 관리체계에 관한 연구)

  • 우세홍;홍상균
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.4
    • /
    • pp.51-58
    • /
    • 1993
  • The integrated solid waste management for Seoul Metropolitan city can be established on the basis of the following hierarchy of priorities: 1. Efforts for source reduction should be propelled by both government and citizens to achieve the effects of resource conservation. The adequate production and consumption which are environmentally amenable and sustainable can be induced by the reasonable imposition of deposit money for waste treatment to one-time use products. To accomplish source reduction effectively, the induction of legal and institutional regulation of producer and consumer participation is requisite. 2. For resource recovery, wastes generated should be recycled as far as practicable. Community residents are responsible to separate discharge, the authorities concerned have responsibility of separate collection, and recycling industry should be assissted through tax reduction and financing. Resource separation facilities can be constructed at Kimpo Metropolitan landfill site for wastes not separately collected due to some unavoidable circumstances. 3. Garbage should be composted. Garbage is uneconomical for incineration, because it has high moisture content and low calorie, thus there is no reason for the incineration of garbage even though garbage is classified into combustibles. Composting facilities can be located at sites which are not densely populated and easily accessible to transportation, for example, Kimpo Metropolitan landfill site. Compost produced can be managed by the authorities for the use of fertilizer to a green tract of suburban land and farms. 4. Nonhazardous combustible wastes not recyclable can be utilized for thermal recovery at the incinerators which are completely equipped with pollution control devices. According to the trend of local autonomy and the equity principle of local autonomous entities, incineration facilities of minimal capacity required can be constructed at each districts of Seoul Metropolitan city which have organized local assembly. In case of Yangcheon district, the economically combustible waste quantity is about 260 tons/day which exceeds 150 tons/day, the incineration capacity of existing facility. But, from now on, waste quantity can be reduced substantially by the intensive efforts of citizens for source reduction and recycling and the institutional support of administrative organizations. Especially, it is indispensable for the government to constitute institutional and technological bases that can recycle paper and plastics form 43% of waste generated. A good time for constructing of incineration facilities for municipal solid waste can be postponed to the time that pollution control technologies of domestic enterprises are fully developed to satisfy the standards of air pollution prevention, because the life expectancy of Kimpo Metropolitan landfill site is about 25 years. Within this period, institutional improvements and technological advancements can be attained, while the air qual. ity of Seoul Metropolitan city can be ameliorated to the level to afford incineration facilities. 5. For final disposal, incombustibles and ash are landfilled sanitarily at Kimpo Metropolitan landfill site.

  • PDF

Proper Monitoring Methods for Safety Management of Tailings Dam (광물찌꺼기적치장의 안전관리를 위한 적정 모니터링 방안 연구)

  • Jung, Myung Chae;Kim, Jeong Wook;Hwang, In-ho;Yang, In Jae;Park, Jay Hyun;Park, Ju Hyun;Kim, Tae Youp
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.576-587
    • /
    • 2018
  • This study has focused on analysis factors affecting safety monitoring system at tailings sites, and the evaluation equipment to monitor the factors. Twenty sites at eighteen mines with unsafe conditions were selected to examine the equipment. There were three main factors influenced safety in the sites including surface erosion, piping, and slope instability. In detail, the surface erosion was divided into three sub-factors (planting, soil-topping layer, and tailings), piping into three sub-factors (liner, rain protection facility and leachate), and slop instability was also divided into three sub-factors (slop, concrete wall, and reinforcing wall). As results of in-field measurement, a CCTV was the most effective facility, and electrical resistivity survey, acoustic sensing, thermal liner sensor, structure inclinometer, rainfall meter, and flowmeter were also highly effective. According to applications of the facilities in the unstable tailings, structural defects were mainly found in the piping, which was the most important monitoring factor for safety management of tailings sites.