• Title/Summary/Keyword: thermal load

Search Result 1,838, Processing Time 0.023 seconds

Long Term Monitoring of Prestressing Tension Force in Post-Tension UHPC Bridge using Fiber Optical FBG Sensor (FBG 광섬유센서가 내장된 7연 강연선을 이용한 포스트텐션 UHPC 교량의 긴장력 장기모니터링)

  • Kim, Hyun-Woo;Kim, Jae-Min;Choi, Song-Yi;Park, Sung-Yong;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.699-706
    • /
    • 2015
  • This paper presents results of one-year monitoring on prestressing force of a 7-wire steel post-tensioning strand which is installed in a UHPC(ultra high performance concrete) bridge with 11.0 m long, 5.0 m wide, and 0.6 m high by using a FBG-encapsulated 7-wire steel strand. The initial prestressing forces and the prestress changes during a vehicle load test were measured using the FBG-encapsulated strand. The results show that the FBG-encapsulated 7-wire strand is very effective for monitoring the prestress forces even the change in the tension force is very small. Additionally, it was indicated that selection of the thermal expansion coefficient which is used for the temperature correction shall be carefully carried out.

A study on structural safety evaluation of jet vane under very high temperature and dynamic pressure (초고온 동압을 받는 제트 베인의 구조 안전성 평가에 대한 연구)

  • Park Sunghan;Lee Sangyeon;Park Jongkyoo;Kim Wonhoon;Moon Soonil
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.99-105
    • /
    • 2005
  • To evaluate structural safety factor of the jet vane for the thrust deflection system under the dynamic pressure and very high temperature($2700^{\circ}C$) of the combustion gas flow, the high temperature tension tests of refractory metals and 3-D nonlinear numerical simulations are performed. Through the analysis of high temperature structural behavior for jet vane, the structural safety of jet vane is evaluated, and numerical results are compared with static pound tests of jet vanes. It has been found that most of structural and thermal loading is concentrated on the vane shaft which worked as safe under $1400^{\circ}C$. From the comparison of static ground tests and numerical results, the evaluation criterion using the vane load and shaft displacement is more useful to estimate the structural safety than using the equivalent stress.

  • PDF

A Study on GUI Development of Structural Analysis of LNG Pump Tower (LNG 운반선용 펌프타워의 구조해석 GUI개발에 관한 연구)

  • Lee, Kang-Su;Son, Choong-Yul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.605-613
    • /
    • 2007
  • The purpose of this study is to develop a structural analysis system of LNG pump tower structure. The system affords to build optimized finite element model and procedure of the pump tower structure. The pump tower structure is one of the most important components of LNG (liquefied natural gas) carriers. The pump tower structure is subject to sloshing load of LNG induced by ship motion depending on filling ratio. Three typer of loading components, which are thermal, inertia and self-gravity are considered in the analysis. The finite element analysis is performed with ANSYS commercial code. The failure of each members can be evaluated of API unity and punching shear in ABS rule. The GUI is newly developed using Tcl/tk script language. All these design and analysis procedures are embedded in to the analysis system successfully.

The Operating Results of the 75kW MCFC Stack (75kW 용융탄산염 연로전지[MCFC] 스택 운전 결과)

  • Kang, Seung-Won;Kim, Beom-Joo;Kim, Do-Hyeong;Lee, Jung-Hyun;Kim, Eui-Hwan;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.3
    • /
    • pp.202-207
    • /
    • 2009
  • A 75kW MCFC stack with the reactive area of 9,600cm$^2$ has been operated and validated in Boryeong thermal power plant. The 75kW MCFC stack was installed at the end of November 28, 2008 and started initial operation on December 23, 2008 after pretreated for about 20 days. At initial load operation, the stack showed the Open Circuit Voltage of 137V, which approaches the theoretical value. At the early stage of rated power operation, the stack displayed the voltage of 104V at the current of 754A and reached the maximum generating power of 78.5kW DC. This stack has been operated for 2,890 hours until April, 2009. In addition, the operation time of rated power records 1890 hours. This Operating result is scheduled to be reflected the design of l25kW stack.

Effects of Fuel Blending Ratio and Oxygen Concentration on Auto-ignition Characteristics of n-Decane/Ethanol Blended Fuels (연료 혼합비율 및 산소농도가 노말데케인/에탄올 혼합연료의 점화특성에 미치는 영향)

  • Oh, Chae Ho;Kang, Ki Joong;Choi, Gyung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.749-757
    • /
    • 2017
  • To cope with the development of alternative fuels and international environmental regulations, this study provides a numerical analysis of the effects of composition and temperature changes of n-decane and ethanol on auto-ignition characteristics. CHEMKIN-PRO is used as the analysis program and the LLNL model is used as the reaction model. The numerical results show that the ignition delay time increases as the mole fraction of ethanol increases for temperatures below 1000 K, where low temperature reactions occur. Because of the high octane number of ethanol, the high percentage of ethanol delays the increase in the concentration of OH radicals that cause ignition. The oxygen concentration in the mixture is changed to apply the exhaust gas recirculation and a numerical analysis is then performed. As the oxygen concentration decreases, the total ignition delay time increases because the nitrogen gas acts as a thermal load in the combustion chamber.

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.

COMPARATIVE STUDY OF GAS-TO-LIQUID (GTL) AS AN ALTERNATIVE FUEL USED IN A DIRECT INJECTION COMPRESSION IGNITION ENGINE

  • Wu, T.;Huang, Z.;Zhang, W.G.;Fang, J.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.421-428
    • /
    • 2007
  • This paper investigates the combustion and emission characteristics of a compression ignition engine fueled with neat and blended Shell's gas-to-liquid (GTL) fuel, which was derived from natural gas through the Fischer-Tropsch process. The experiments were conducted in a 6-cylinder DI diesel engine with pump timing settings of $6^{\circ},\;9^{\circ}\;and\;12^{\circ}$crank angle before TDC over ECE R49 and US 13-mode cycles separately and compared to a conventional diesel fuel. The results show that GTL exhibited almost the same power and torque output, improved fuel economy and effective thermal efficiency. It was found that GTL displayed lower peak in-cylinder combustion pressure and maximum heat release rate (HRR), the timings of the peak pressure and the maximum HRR were generally delayed, and the combustion durations were almost equivalent for diesel and GTL under the same speed-load condition. The results also indicate that, compared to diesel fuel, GTL blends showed a trend forward decreasing four regulated emissions simultaneously and a higher GTL fraction in blends contributing to further reductions in the emissions. In particular and on average, neat GTL significantly reduced HC, CO, NOx and PM by 16.4%, 17.8%, 18.3% and 32.4%, respectively, for all cases.

Optimization of 30 cm Lightweight Mirror (30 cm 급 반사경 경량화 최적 설계)

  • Kim, Bong-Ho;Lee, Jong-Ung;Moon, Il-Kwon;Yang, Ho-Soon;Kihm, Hag-Yong;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.214-223
    • /
    • 2010
  • Optimization of a 30 cm lightweight mirror was proposed with the best optical performance under various loads of gravity and thermal loads with proper boundary conditions. A pattern for a lightweight mirror was generated based on the best optical performance combined with ease of manufacturing for proper design parameters of physical properties of face sheet, back sheet, rib, and web. Evaluation of the optical performances of a telescope mirror was obtained by using the finite element analysis program, NX I-DEAS. Surface errors, individual aberration terms, such as piston, tilts, focus and other aberrations were calculated by using Zernike polynomials. The proposed telescope mirror meets well the opto-mechanical design consideration of RMS surface error less than 16 nm.

DESIGN OF A PWR POWER CONTROLLER USING MODEL PREDICTIVE CONTROL OPTIMIZED BY A GENETIC ALGORITHM

  • Na, Man-Gyun;Hwang, In-Joon
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.81-92
    • /
    • 2006
  • In this study, the core dynamics of a PWR reactor is identified online by a recursive least-squares method. Based on the identified reactor model consisting of the control rod position and the core average coolant temperature, the future average coolant temperature is predicted. A model predictive control method is applied to designing an automatic controller for the thermal power control of PWR reactors. The basic concept of the model predictive control is to solve an optimization problem for a finite future at current time and to implement as the current control input only the first optimal control input among the solutions of the finite time steps. At the next time step, this procedure for solving the optimization problem is repeated. The objectives of the proposed model predictive controller are to minimize both the difference between the predicted core coolant temperature and the desired temperature, as well as minimizing the variation of the control rod positions. In addition, the objectives are subject to the maximum and minimum control rod positions as well as the maximum control rod speed. Therefore, a genetic algorithm that is appropriate for the accomplishment of multiple objectives is utilized in order to optimize the model predictive controller. A three-dimensional nuclear reactor analysis code, MASTER that was developed by the Korea Atomic Energy Research Institute (KAERI) , is used to verify the proposed controller for a nuclear reactor. From the results of a numerical simulation that was carried out in order to verify the performance of the proposed controller with a $5\%/min$ ramp increase or decrease of a desired load and a $10\%$ step increase or decrease (which were design requirements), it was found that the nuclear power level controlled by the proposed controller could track the desired power level very well.

A Refurbishment life Diagnosis for Overhead Transmission Conductors using Dip Measurement (이도 측정에 의한 가공송전선 도체의 교체수명 진단)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.139-146
    • /
    • 2008
  • Conductors in overhead transmission lines are exposed under various environmental conditions for a long period of time, so that they may be slowly degraded due to air pollutant or thermal history. Aged conductors may reduce power system reliability and public safety. Therefore, diagnosis of aged conductors in service becomes more important concerns with respect to keeping power delivery stable with a proper capability, replacing aged conductors, or constructing a new line. In this paper, we posed a new method to diagnose the refurbishment life and estimate the remaining life of aged conductors by measuring dips. As analyzing some relations of conductor temperature, conductor current, and tension load, it could be verified that dip exactly shows mechanical tension loss for aged conductor. Based on several simulation results, it was shown that the proposed method may be effectively used to diagnose the refurbishment life or remaining one of overhead conductors.