• 제목/요약/키워드: thermal limit

검색결과 499건 처리시간 0.023초

완전혼합영역을 갖는 성층축열조의 충전과정에 대한 이론적인 해석 (Theoretical Analysis of the Charging Process with Perfectly Mixed Region in Stratified Thermal Storage Tanks)

  • 유호선;박이동
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.184-195
    • /
    • 1995
  • A theoretical one-dimensional model for the charging process in stratified thermal storage tanks is established presuming that the fluid ensuing from the tank inlet creates a perfectly mixed, layer above the thermocline. Both the generic and asymptotic closed-form solutions are obtained via the Laplace transformation. The asymptotic solution describes the nature of the charging pertaining to the case of no thermal diffusion, whereas the generic solution is of practical importance to understand the role of operating parameters on the stratification. The present model is validated through comparison with available experimental data, where they agree well with each other within a reasonable limit. An interpretation of the exact solution entails two important features associated with the charging process. The first is that an in-crease in the mixing depth $h_m$ causes a relatively slow temperature rise in the perfectly mixed region, but on the other hand it results in a faster decay of the overall temperature gradient across the thermocline. Next is the predominance of the mixing depth in the presence of the prefectly mixed region. In such a case the effect of the Peclet number is marginal and there-fore the thermal characteristics are solely dependent on the mixing depth paticularly for large $h_m$. The Peclet number affects significantly only for the case without mixing. Variation of the storage efficiency in response to the change in the mass flow rate agrees favorably with the published experimental results, which confirms the utility of the present study.

  • PDF

철도차량 객차내 온열환경 측정 분석 (Measurement and Analysis of Indoor Thermal Environment in Passenger Car)

  • 소진섭;유성연
    • 한국철도학회논문집
    • /
    • 제11권2호
    • /
    • pp.120-125
    • /
    • 2008
  • 환경부는 2006년 12월에 대중교통수단 실내공기질 관리 가이드라인을 마련하였다. 관리항목으로 이산화탄소($CO_2$)와 미세먼지(PM10)에 대해 가이드라인을 제시하였다. 이에 따라 객차내 온열환경에 대한 관심이 높아지고 있으며, 승객이 실내에서 느끼는 온열환경 범위는 어느 정도인지 연구의 필요성이 대두되고 있다. 본 연구는 KTX, 무궁화호, 새마을호 객차 실내를 대상으로 2007년 9월과 10월에 측정을 하였다. 그리고 ASHRAE Handbook에 제시하고 있는 온열환경 범위가 어느 정도인지 분석하였다. 그 결과 평균 PMV 값은 KTX가 0.1과 0.22, 무궁화호가 0, 새마을호가 0.1로, 이는 ASHRAE Handbook의 -0.5 < PMV < +0.5범위에 만족한 수준으로 나타났다.

온침 시술 시 생체 조직 내 열분포 분석에 관한 연구 (Thermal Distribution in Living Tissue during Warm Needling Therapy)

  • 김종연;이종수
    • 한방재활의학과학회지
    • /
    • 제24권3호
    • /
    • pp.111-119
    • /
    • 2014
  • Objectives This study aims to analyze a thermal distribution in biological living tissue during warm needling therapy by using a finite element method. The analysis provides an understanding of warm needling's efficacy and safety. Methods A model which consisted of four-layered tissue and stainless steel needle was adopted to analyze the thermal distribution in living tissue with a bioheat transfer analysis. The governing equation for the analysis was a Pennes' bioheat equation. A heat source characteristic of warm needling therapy was obtained by previous experimental measurements. The first analysis of the time-dependent temperature distribution was conducted through points on a boundary between the needle and the tissue. The second analysis was conducted to visualize the horizontal temperature distribution. Results When heat source's peak temperatures was above $500^{\circ}C$ and temperature rising rates were relatively slow, the peak temperature at skin surface exceeded a threshold of pain and tissue damage ($45^{\circ}C$), whereas when the peak temperature was around $400^{\circ}C$, the peak temperature at the skin surface was within a safe limit. In addition, the conduction of combustion energy from the moxa was limited to the skin layer around the needle. Conclusions The results suggest that the skin layer around the needle can be heated effectively by warm needling therapy, but it appears to have little effect at the deeper tissue. These findings enhance our understanding of the efficacy and the safety of the warm needling therapy.

n-InGaAs MOSFETs을 위한 Pd 중간층을 이용한 Ni-InGaAs의 열 안정성 개선 (Improvement of Thermal Stability of Ni-InGaAs Using Pd Interlayer for n-InGaAs MOSFETs)

  • 이맹;신건호;이정찬;오정우;이희덕
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.141-145
    • /
    • 2018
  • Ni-InGaAs shows promise as a self-aligned S/D (source/drain) alloy for n-InGaAs MOSFETs (metal-oxide-semiconductor field-effect transistors). However, limited thermal stability and instability of the microstructural morphology of Ni-InGaAs could limit the device performance. The in situ deposition of a Pd interlayer beneath the Ni layer was proposed as a strategy to improve the thermal stability of Ni-InGaAs. The Ni-InGaAs alloy layer prepared with the Pd interlayer showed better surface roughness and thermal stability after furnace annealing at $570^{\circ}C$ for 30 min, while the Ni-InGaAs without the Pd interlayer showed degradation above $500^{\circ}C$. The Pd/Ni/TiN structure offers a promising route to thermally immune Ni-InGaAs with applications in future n-InGaAs MOSFET technologies.

Analyses on Thermal Stability and Structural Integrity of the Improved Disposal Systems for Spent Nuclear Fuels in Korea

  • Lee, Jongyoul;Kim, Hyeona;Kim, Inyoung;Choi, Heuijoo;Cho, Dongkeun
    • 방사성폐기물학회지
    • /
    • 제18권spc호
    • /
    • pp.21-36
    • /
    • 2020
  • With respect to spent nuclear fuels, disposal containers and bentonite buffer blocks in deep geological disposal systems are the primary engineered barrier elements that are required to isolate radioactive toxicity for a long period of time and delay the leakage of radio nuclides such that they do not affect human and natural environments. Therefore, the thermal stability of the bentonite buffer and structural integrity of the disposal container are essential factors for maintaining the safety of a deep geological disposal system. The most important requirement in the design of such a system involves ensuring that the temperature of the buffer does not exceed 100℃ because of the decay heat emitted from high-level wastes loaded in the disposal container. In addition, the disposal containers should maintain structural integrity under loads, such as hydraulic pressure, at an underground depth of 500 m and swelling pressure of the bentonite buffer. In this study, we analyzed the thermal stability and structural integrity in a deep geological disposal environment of the improved deep geological disposal systems for domestic light-water and heavy-water reactor types of spent nuclear fuels, which were considered to be subject to direct disposal. The results of the thermal stability and structural integrity assessments indicated that the improved disposal systems for each type of spent nuclear fuel satisfied the temperature limit requirement (< 100℃) of the disposal system, and the disposal containers were observed to maintain their integrity with a safety ratio of 2.0 or higher in the environment of deep disposal.

Effect of Gamma Ray Irradiation on the Mechanical and Thermal Properties of MWNTs Reinforced Epoxy Resins

  • Shin, Bum Sik;Shin, Jin Wook;Jeun, Joon Pyo;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.137-143
    • /
    • 2011
  • Epoxy resins are widely used as high performance thermosets in many industrial applications, such as coatings, adhesives and composites. Recently, a lot of research has been carried out in order to improve their mechanical properties and thermal stability in various fields. Carbon nanotubes possess high physical and mechanical properties that are considered to be ideal reinforcing materials in composites. CNT-reinforced epoxy system hold the promise of delivering superior composite materials with their high strength, light weight and multi functional features. Therefore, this study used multi-walled carbon nanotubes (MWNT) and gamma rays to improve the mechanical and thermal properties of epoxy. The diglycidyl ether of bisphenol A (DGEBA) as epoxy resins were cured by gamma ray irradiation with well-dispersed MWNTs as a reinforcing agent and triarylsulfonium hexafluoroantimonate (TASHFA) as an initiator. The flexural modulus was measured by UTM (universal testing machine). At this point, the flexural modulus factor exhibits an upper limit at 0.1 wt% MWNT. The thermal properties had improved by increasing the content of MWNT in the result of TGA (thermogravimetric analysis). However, they were decreased with increasing the radiation dose. The change of glass transition temperature by the radiation dose was characterized by DMA (dynamic mechanical analysis).

LiAlH4-PVDF 전해질 복합체의 열확산 및 전기화학적 특성평가 (Evaluation of Thermal Diffusivity and Electrochemical Properties of LiAlH4-PVDF Electrolyte Composites)

  • 황준현;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.574-582
    • /
    • 2022
  • A lithium-ion battery exhibits high energy density but has many limitations due to safety issues. Currently, as a solution for this, research on solid state batteries is attracting attention and is actively being conducted. Among the solid electrolytes, sulfide-based solid electrolytes are receiving much attention with high ion conductivity, but there is a limit to commercialization due to the relatively high price of lithium sulfide, which is a precursor material. This study focused on the possibility of relatively inexpensive and light lithium hydride and conducted an experiment on it. In order to analyze the characteristics of LiAlH4, ion conductivity and thermal stability were measured, and a composites mixed with PVDF, a representative polymer electrolyte, was synthesized to confirm a change in characteristics. And metallurgical changes in the material were performed through XRD, SEM, and BET analysis, and ion conductivity and thermal stability were measured by EIS and LFA methods. As a result, Li3AlH6 having ion conductivity higher than LiAlH4 is formed by the synthesis of composite materials, and thus ion conductivity is slightly improved, but thermal stability is rapidly degraded due to structural irregularity.

지중관로에서의 실제 허용전류 산출을 위한 도체온도 계산 알고리즘 개선에 관한 연구 (Improvement of the Conductor Temperature Calculation Algorithm for Calculating the Allowable Current in the Underground Channel)

  • 이향범;이병철;김정훈;남용현;강지원
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.352-357
    • /
    • 2018
  • In this paper, the improvement of the conductor temperature calculation algorithm is studied. The allowable current of the underground transmission line is determined by the conductor temperature limit. Usually to calculate the allowable current limit, the conductor temperature is assumed in the most worst environment condition. It is possible to increase the transmission capacity if the actual burial environment is considered. Therefore, in this paper an algorithm is proposed to calculate the conductor temperature by distinguishing two area of a underground transmission line condition - the manhole where the temperature sensor can be installed and the underground transmission line in which the temperature sensor can not be installed easily. When calculating the conductor temperature by the underground line in the pipeline, the existing standard describes each environment as a single soil heat resistance and one ambient temperature. In order to compensate this situation, thermal resistance model that can take into consideration the ground surface temperature and under ground temperature is proposed. It is shown that the accuracy of the proposed model is increased compared with the existing standard calculation result.

HCNG 엔진의 NOx 배출특성에 관한 연구 (A Study on the NOx Emission Characteristics of HCNG Engine)

  • 박철웅;김창기;최영;원상연;이선엽
    • 한국자동차공학회논문집
    • /
    • 제19권4호
    • /
    • pp.78-83
    • /
    • 2011
  • Natural gas is one of the most promising alternatives to gasoline and diesel fuels because of its high thermal efficiency and lower harmful emissions, including $CO_2$. Although the high octane value of natural gas increases engine output and efficiency due to the high compression ratio, this fuel is prone to such difficulties as a narrow limit of inflammability and a slow combustion speed in the lean burn operation domain, leading to unstable combustion and higher emissions of harmful exhaust gases. Hydrogen blended with natural gas can extend the lean burn limit while maintaining stable, efficient combustion and achieving lower NOx, hydrocarbon and green house gas emissions. In this study, the effect of hydrogen addition on an engine performance and NOx emission characteristics was investigated in a heavy duty natural gas engine. The results showed that thermal efficiency was increased and NOx emissions were reduced due to the expansion of lean operation range under stable operation. NOx emission can be significantly reduced with the retard of spark advance timing.

소결 금속 윅 히트파이프 개발을 위한 제조 기술 연구 (A Study on the Manufacturing Technology for the Development of Heat Pipes with a Sintered Metal Wick)

  • 최지훈;김성대;성병호;유성열;박형기;김철주;고한서
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.479-482
    • /
    • 2006
  • The most the electronic industry has recently accelerated the modularization, the miniaturization and the high integrated trend of electronics fields such as electronics components, appliances and etc., the most increasingly the heat generation problem rises. Even though the conventional cooling technologies are widely used in order to reduce the heat loads, the technologies are not easy to meet the present trends due to the fact that most of many conventional methods are relative to external form environments such as size, design and so on. With regardless of those environments, however, a heat pipe is one of the most efficient systems to improve the heat transfer performance. And then the performance of the heat pipe depends on a wick structure. Of various wick structures, sintered metal wick is known so that it has some advantages such as smaller pore size, increasing porosity as well as high reliability. In this study sintered metal wicks, thickness 0.7 mm, 0.8 mm and 0.9 mm, were manufactured as of $100{\mu}m$ copper powder to obtain the manufacturing technology of heat pipes mounted with a sintered metal wick. Furthermore, experiments for the operational performance factors such as capillary limit, thermal resistance were not only performed but also compared with a theoretical model simultaneously. Experimental results agreed with the theoretical model, and then it seems to be required to study various development processes of sintered metal wicks for the high performance of a heat pipe system.

  • PDF