• Title/Summary/Keyword: thermal insulator

Search Result 296, Processing Time 0.036 seconds

Fabrication and performance test of persistent current switch for superconducting magnet (초전도 마그네트용 영구전류스위치의 제작 및 성능 평가)

  • 고락길;배준한;심기덕;이언용;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.189-192
    • /
    • 2001
  • In order to design thermally trigger controlled persistent current switch (PCS) for superconducting magnet system, it is very important to know information of applied adiabatic method and condition to get designed resistance and characteristics In this paper, we used cotton-gummed tape as thermal insulator and derived experimentally averaged thermal conductivity of it around 10K on the assumption that adiabatic structure of PCS is shape of pipe. The result value is about 0.29 W/mK and it is verified reasonable value by computer simulation and experiment of test PCS. Test PCS was designed and manufactured different dimensions. The experimental results of test PCS were in good agreement with the calculated results.

  • PDF

Passive Heat Removal Characteristics of SMART

  • Seo, Jae-Kwang;Kang, Hyung-Seok;Yoon, Joo-Hyun;Kim, Hwan-Yeol;Cho, Bong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.623-628
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt thermal capacity named SMART (System-Integrated Modular Advanced Reactor) is currently under development in Korea Atomic Energy Research Institute (KAERI) for multi-purpose applications. Modular once-through steam generator (SG) and self-pressurizing pressurizer equipped with wet thermal insulator and cooler are essential components of the SMART. The SMART Provides safety systems such as Passive Residual Heat Removal System (PRHRS). In this study, a computer code for performance analysis of the PRHRS is developed by modeling relevant components and systems of the SMART. Using this computer code, a performance analysis of the PRHRS is performed in order to check whether the passive cooling concept using the PRHRS is feasible. The results of the analysis show that PRHRDS of the SMART has excellent passive heat removal characteristics.

  • PDF

Finite element simulation of drying process for ceramic electric insulators (세라믹 애자 건조공정의 유한요소 시뮬레이션)

  • 정준호;금영탁;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.3
    • /
    • pp.347-352
    • /
    • 1999
  • The finite element formulation and simulation of drying process for ceramic electric insulators are investigated. The heat and moisture movements in green ceramics caused by the interaction of temperature gradient, moisture gradient, conduction, convection and evaporation are considered. The variations of temperature and moisture not only change the volume but also induce the hygro-thermal stress. The finite element formulation for solving the temperature and moisture distributions as well as the associated hygro-thermal stresses is derived. Using the computer code developed, the drying process of a ceramic electric insulator is simulated. Temperature distribution, moisture distribution, hygrothermal stress and deformed shape during the drying process are predicted.

  • PDF

Thermal Properties of XLPE Insulatorl Nano Semiconducting Materials in Power Cable (전력케이블용 XLPE절연체/ 나노 반도전층 재료의 열적 특성)

  • Yang, Jong-Seok;Choi, Sung-Hun;Park, Jabg-Hyeon;Sung, Baek-Ryong;Lee, Jae-Hyeung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.30-31
    • /
    • 2006
  • To improve the mean-life and the reliability of power cable, we have investigated specific heat (Cp). Specific-heat measurement temperature ranges of XLPE insulator were from $20[^{\circ}C]$ to $90[^{\circ}C]$, and the heating rate was $1[^{\circ}C/min]$. In case of semiconducting materials, the measurement temperature ranges of specific heat were from $20[^{\circ}C]$ to $60[^{\circ}C]$ and the heating rate was $1[^{\circ}C/min]$. From these experimental results, both specific heat were increased by heating rate because volume of materials was expanded according to rise in temperature. We could know that a small amount of CNT has a excellent thermal properties.

  • PDF

Electric Characteristics of Tantalum Pentoxide Thin Film Formed by Thermal Oxidation (열산화법으로 형성한 탄탈륨 산화막의 전기적 특성)

  • 홍영호;박효덕;전춘배;이덕동;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.3
    • /
    • pp.87-95
    • /
    • 1992
  • The electrical characteristics of Al/TaS12TOS15T/SiOS12T/Si metal insulator-semiconductor (MIS) capacitors were studied. Tantalum pentoxide thin films on SiOS12T/p-Si substrate have been prepared by thermal oxidation at 450-$600^{\circ}C$ of sputter deposited tantalum films. Composition and structures of the tantalum oxide films were examined by AES and XRD. From the C-V analysis, dielectric constant of TaS12TOS15T which were oxidized at 55$0^{\circ}C$ for 1h in OS12T were 18-23, the value depending on the oxidation and annealing temperature. The leakage current density was found to be about 10S0-10T-10S0-9T A/cmS02T at an applied electric field of 1 MV/cm. The dielectric breakdown strength of the tantalum oxide films annealed at 100$0^{\circ}C$ were in the range from 2.5MV/cm to 2.8 MV/cm.

  • PDF

Design of Low Consume Power Ty7e Micro-heaters Using SOl and Trench Structures (SOI 및 TRENCH 구조를 이용한 저소비 전력형 미세발열체의 설계)

  • Jang, Soo;Hong, Seok-Woo;Lee, Jong-Chun;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.350-353
    • /
    • 1999
  • This Paper Presents the optimized design of micro-heaters using 501(Si-on-insulator) substrate and oxide-filled trench structure In order to justify a lumped model approximation and thermal boundary assumptions, two-dimensional FDM(finite difference among which conduction is the dominant heat dissipation path. Compared with no-trenchs on the SOI structure, the micro-heaters with trench structures has properties of low heater loss and good thermal isolation. The simulation results show that the heater loss decreases as the number. width and distance of trenchs increases.

  • PDF

Chemically Bonded Thermally Expandable Microsphere-silica Composite Aerogel with Thermal Insulation Property for Industrial Use

  • Lee, Kyu-Yeon;Phadtare, Varsha D.;Choi, Haryeong;Moon, Seung Hwan;Kim, Jong Il;Bae, Young Kwang;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.23-29
    • /
    • 2019
  • Thermally expandable microsphere and aerogel composite was prepared by chemical compositization. Microsphere can produce synergies with aerogel, especially an enhancement of mechanical property. Through condensation between sulfonated microsphere and hydrolyzed silica sol, chemically-connected composite aerogel could be prepared. The presence of hydroxyl group on the sulfonated microsphere was observed, which was the prime functional group of reaction with hydrolyzed silica sol. Silica aerogel-coated microsphere was confirmed through microstructure analysis. The presence of silicon-carbon absorption band and peaks from composite aerogel was observed, which proved the chemical bonding between them. A relatively low thermal conductivity value of $0.063W/m{\cdot}K$ was obtained.

Characteristics of Nonthermal Plasma Source in Various Liquids

  • Lim, Seung-Ju;Min, Boo-Ki;Taylor, Nathan;Kim, Tae-Gyu;Kim, Hyeong-Seok;Yang, Seon-Pil;Jung, Jin-Yong;Han, Jin-Hyun;Lee, Jong-Yong;Kang, Seung-Oun;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.259.1-259.1
    • /
    • 2014
  • Recently non-thermal plasma has been frequently applied to various research fields. The liquid plasma have received much attention lately because of interests in surgical and nanomaterial synthesis applications. Especially, intensive researches have been carried out for non-thermal plasma in liquid by using various electrode configurations and power supplies. We have developed a bioplasma source which could be used in a liquid, in which outer insulator has been covered onto the outer electrode. Also we have also put an insulator between the inner and outer electrode. Based on the surface discharge mode, the nonthermal bioplasma has been generated inside a liquid by using an alternating current voltage generator with peak voltage of 12 kV under driving frequency of 22 KHz. Here the discharge voltage and current have been measured for electrical characteristics. Especially, We have measured discharge and optical characteristics under various liquids of deionized (DI) water, tap water, and saline by using monochromator. We have also observed nitric oxide (NO), hydrogen peroxide (H2O2), and hydroxyl (OH) radical species by optical emission spectroscopy during the operation of bioplasma discharge inside various kinds of DI water, tap water, and saline. Here the temperature has been kept to be $40^{\circ}C$ or less when discharge in liquid has been operated in this experiment. Also we have measured plasma temperature by high speed camera image and density by using either H-alpha or H-beta Stark broadening method.

  • PDF

High Performance p-type SnO thin-film Transistor with SiOx Gate Insulator Deposited by Low-Temperature PECVD Method

  • U, Myeonghun;Han, Young-Joon;Song, Sang-Hun;Cho, In-Tak;Lee, Jong-Ho;Kwon, Hyuck-In
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.666-672
    • /
    • 2014
  • We have investigated the gate insulator effects on the electrical performance of p-type tin monoxide (SnO) thin-film transistors (TFTs). Various SnO TFTs are fabricated with different gate insulators of a thermal $SiO_2$, a plasma-enhanced chemical vapor deposition (PECVD) $SiO_x$, a $150^{\circ}C$-deposited PEVCD $SiO_x$, and a $300^{\circ}C$-deposited PECVD $SiO_x$. Among the devices, the one with the $150^{\circ}C$-deposited PEVCD $SiO_x$ exhibits the best electrical performance including a high field-effect mobility ($=4.86cm^2/Vs$), a small subthreshold swing (=0.7 V/decade), and a turn-on voltage around 0 (V). Based on the X-ray diffraction data and the localized-trap-states model, the reduced carrier concentration and the increased carrier mobility due to the small grain size of the SnO thin-film are considered as possible mechanisms, resulting in its high electrical performance.

The Thermal Insulation of Warm Fluid using Aluminium Foil in Trauma Care (외상환자 수액 투여에서 알루미늄 호일을 이용한 단열 효과)

  • Kim, Seo Jin;Sun, Kyung Hoon;Park, Yong Jin;Kim, Sun Pyo
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.20-24
    • /
    • 2014
  • Purpose: The temperature of a warm fluid infused into a patient is lowered because the line that allows the fluid to be infused into the patient is exposed to room air. This study evaluated the effects of aluminum foil used as an insulator surrounding the fluid infusion lines when using warm crystalloid fluids to treat traumatic shock patients. Methods: The study measured the differences in fluid temperature between infusion lines with and without the aluminum-foil insulation. We used 1L of normal saline at $40^{\circ}C$ as the infusion fluid, and the fluid infusion line was 200 cm long. The differences in temperature were measured for various fluid flow rates from 12,000 mL/min to 100 mL/min. We performed three experiments at each flow rate. Results: The results showed the differences in temperature between the groups with and without the aluminum insulation were significant for flow rates above 100 mL/min. Conclusion: Hypothermia in trauma patients results in many adverse complications such as peripheral vascular constriction, tissue hypoxia, metabolic acidosis, heart dysfunction and so on. Thus, the use of warm fluids and blood components is essential to reduce the probability of hypothermia. This study showed the aluminum foil wrapped around the infusion line had an insulator effect. As a result, such a wrapping can be used to avoid the adverse effects of hypothermia.