• 제목/요약/키워드: thermal insulation

검색결과 1,179건 처리시간 0.027초

써멀마네킨을 이용한 단일의복의 중량과 보온력에 관한 연구 (The Relationship between Weight of Single Garments and Thermal Insulation with a Thermal Manikin)

  • 최정화;이효현
    • 한국의류학회지
    • /
    • 제33권2호
    • /
    • pp.173-186
    • /
    • 2009
  • The purpose of this study was to examine the relationship between the weight of seasonal garments worn by Korean women in their daily lives and thermal insulation. We selected a total of 121 garments(13 kinds of Under garments, 51 Upper garments, 32 Lower garments, 15 Headgear, 10 Gloves Footgear) based on our previous survey using questionnaire and interview. Thermal insulation of single garment was measured with a thermal manikin. Also we measured garment weight, covering area, thickness, air permeability on the each garment(chamber air temperature: $21.5{\pm}0.5^{\circ}C$, humidity: $50{\pm}5%R.H.$ air speed: 0.15m/s). The results are as follow: The very strong positive correlation(r=0.905, p<.01) was recognized between the weight of single garment and thermal insulation. The regression equation of thermal insulation can be represented as follows: Thermal Insulation(clo)=$0.03+0.0004{\times}Garment$ Weight(g)($r^2$=0.820, SEE =0.059). There are significant differences in the thermal insulation and garment weight by season and garment type(p<.05). The each garment category's thermal insulation and garment weight has as follows: Under garment(0.06clo, 89g), Blouse Shirt T-shirt(0.13clo, 200g), Cardigan Sweater Vest(0.14clo, 287g), Coat Jacket Jumper(0.41clo, 890g), Skirt(0.16clo, 276g), Trousers(0.20clo, 438g), Headgear(0.03clo, 102g), Gloves Footgear(0.03clo, 33g).

The Study on Thermal Performance Evaluation of Building Envelope with VIPs

  • Jeon, Wan-Pyo;Kwon, Gyeong-Jin;Kim, Jin-Hee;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: The energy consumption in buildings has continuously increased in some countries and it reaches almost 25% of the total energy use in korea. Therefore there are various efforts to minimize energy consumption in buildings, and the regulations on building envelope insulation have been tightened up gradually. To satisfy the building regulation, the use of vacuum insulation panels(VIPs) is increasing. VIP is a high performance insulation materials, so that it can be thinner than conventional insulation material. When VIP is applied in a building, it may cause thermal bridge, which occurs due to very low thermal conductivity compared to other building materials and the envelope of VIPs. Method: This study designed the capsulized VIPs using conventional insulation for reduction of the thermal bridge. Then designed VIPs were applied to a wall. The linear thermal transmittance and the effective thermal conductivity were analyzed by HEAT2 simulation program for two dimensional steady-state heat transfer. The result compared with a wall with non-capsulized VIPs. Result: It analyzed that the wall with capsulized VIPs had lower linear thermal transmittance and reduced the difference of the effective thermal transmittance with one dimensional thermal transmittance compared to that of the wall with non-capsulized VIPs.

표면코팅 구조재의 달열효과 분석 (An Analysis on Thermal Insulation Effect of Farm Structures Coated with Surface Treatment)

  • 서원명;윤용철
    • 한국농공학회논문집
    • /
    • 제46권4호
    • /
    • pp.39-46
    • /
    • 2004
  • This experiment was carried out to study on the effect of surface coating on thermal insulation of farm structures to improve thermal resistance and reflective effect of solar radiation. Nine different types of experimental specimen were compared in the temperature variations of inside and outside; A, B, C, D. E and F types are box container and G, H and I types are drum container. The size of these containers is $1,500{\times}2,000{\times}2,500$ mm and ${\varphi}$ $280{\times}330$ mm, respectively. Specimen of 3-type box(A, B, C) is galvanized steel sheet of thickness 0.45 mm. D, E and F types are sandwich panel of the thickness 50 mm inserted with urethane, glass wool and polystyrene form, respectively. G, H and I types are paint pot using in general. The surface of A. D, E, F and I types didn't any treatment, B, C and G types were treated with thermal insulation coating on the outside surface(B, G) or the inside and outside surface(C). And H type was treated with water paint coating on the only outside surface. In general, the experimental results showed the following tendencies; In case of A, B and C types. it was found that the thermal insulation effect of types coated with thermal insulation coating was improved remarkably than that of no treatment. And the thermal insulation effect between steel sheet and sandwich panel type was nearly similar There was not a significant difference of thermal insulation effect between thermal insulation coating and water paint coating. In time of drum container filled with rough rice, The difference of heat transfer tendency and temperature variation among surface treatments was nearly similar that of box types of galvanized steel sheet. And there was time lag about 6 hours between the temperature of middle part of rice and that of inside or outside surface.

SOFC Hot BOP 단열재 적용 방법에 따른 열평형 기대 효과에 대한 수치해석 연구 (A Numerical Study on the Expectation Effect of Thermal Balance according to SOFC Hot BOP Insulation Application Method)

  • 최규홍;황승식;김동균;최종균
    • 한국수소및신에너지학회논문집
    • /
    • 제28권5호
    • /
    • pp.512-520
    • /
    • 2017
  • This paper is a numerical study of various methods of applying SOFC hot BOP insulation. The application methods are four cases from case 1 to case 4, and the performance difference between the result of applying powdered insulation and the result of zoning using composite multi-layer insulation was examined. Numerical results show that the thermal stability of composite multi-layer insulation is better than that of powder insulation when the thermal conductivity is 0.04 W/mK. In the future, we will increase the thermal conductivity of the composite multi-layer thermal insulation material and find the greatest value of thermal conductivity with a similar result to that of the powder insulation.

단열 보완형 복합방수공법의 단열성능에 관한 연구 (Thermal Insulation Performance of Composite Waterproofing Method of Thermal Supplement Type)

  • 최성민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.59-66
    • /
    • 2014
  • 건설구조물 상부의 단열은 에너지 절약 건설구조물에 있어서 중요한 요건 중 하나이다. 건설구조물 최상부는 단열성뿐만 아니라 방수성능도 중요하다. 이와 같은 이유로 단열성을 확보한 방수공법의 개발이 요구된다. 본 연구에서는 최근 일정 단열성능을 확보한 단열 보완형의 복합방수공법이 개발되어 해당 공법에 대한 단열성능을 평가하고자 하였다. 방수성 시험결과, 모든 시험체는 KS 표준 이상의 성능을 보여주었다. 단열성 시험결과, 스티로폼 박스가 가장 높은 온도인 $25.91^{\circ}C$, 버블시트 박스가 $17.28^{\circ}C$, 단열시트 박스가 $15.47^{\circ}C$, 단열보완형 방수시트가 $24.11^{\circ}C$로 확인되었다. 시트 접합부의 열교현상을 관찰한 결과 열교현상은 발생하지 않았다. 단열보완형 복합방수공법은 단열성능을 확보하고 있는 것으로 판단된다.

수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발 (Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically)

  • 오홍영;송기오;전현익;조선영
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가 (Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame)

  • 송진희;이동윤;신동일;전현도;박철용;김상균
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

이부자리 보온력에 관한 연구(III) - 요의 보온력 - (Studies on the Thermal Insulation Effect of Bedding(III) - Thermal Insulation Effect of Underquilt -)

  • 이송자;성수광
    • 한국의류학회지
    • /
    • 제17권2호
    • /
    • pp.301-306
    • /
    • 1993
  • Since the underquilt has an important role of supporting the human body in sleeping, it needs to sustain ample degrees of hardness, elasticity, humidity absorption, and warmth retention property and also to have the two ergonimical requirements : It should not be too soft to allow human bodies to sink in, and that it should be comfortable for humans to tum over in sleeping. This study aims to investigate the effect of the thermal insulation of the variation in weight applied to the underquilt. For this purpose, six items were selected as filling materials for the underquilt : cotton, wool, silk, down, polyester, cotton/ployester. Various weights were applied to each of the underquilts to survey the reduction tendency of its thermal insulation effect. The results are as follow : 1. The Thermal insulation effect of each underquilt decreased in an exponetial function as the weight on the underquilt was increased. 2. The thermal reduction curves according to the load weight insrease were shown to be constant in shape regardless of the weight increase. 3. At the weight of more than $25kg/m^2$ the degree of the thermal insulation effect of each underquilt was found to be in order of down>cotton>silk>polyester>wool>cotton/ployester. 4. The variation in load weight applied to each underquilt was shown to be in reverse correlation with the thermal insulation effect. An estimated regression formula can be made on the data.

  • PDF

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석 (Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window)

  • 이장만;조수;임상훈;송규동
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.150-155
    • /
    • 2013
  • Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.