• 제목/요약/키워드: thermal imaging

검색결과 626건 처리시간 0.028초

Standardization of diagnosis of cold hypersensitivity of hands and feet by D.I.T.I.

  • Lee, Kyung-Sub
    • 대한한방체열의학회지
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2004
  • Cold hypersensitivity means a condition feeling cold at a temperature when one should not feel so. Cold hypersensitivity has been diagnosed based on the patient's subjective complaints. But these days, cold hypersensitivity can be diagnosed by the help of D.I.T.I.(Digital Infrared Thermal Imaging) This study is designed to verify the validity of diagnosis of cold hypersensitivity by D.I.T.I. Thermographic findings of 100 outpatients who visited the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from June 2000 to November 2000 were analyzed. The experimental group consisted of 50 patients who complained cold hypersensitivity, and for the control group, 50 patients who did not complain cold hypersensitivity. For the diagnosis of cold hypersensitivity of the hands, thermographic measurements were performed on two pairs of areas(palm-upper arm and back of hand-upper arm). And for that of the feet, other two pairs of areas(anterior thigh-top of the feet and posterior thigh-heel). When the criterion for thermal deviation between the palm and the upper arm was appointed as higher than $0.3^{\circ}C$, the sensitivity was 94.0% and the specificity, 90.0%. And when the criterion for that between the anterior thigh and the top of feet was appointed higher than $2.0^{\circ}C$, the sensitivity was 94.0% and the specificity, 76.0%. Through this study, the diagnostic standard for cold hypersensitivity of hands and feet could be presented.

  • PDF

수부냉증이 있는 산모의 체성분학적 특성 분석 (Body Composition Analysis Study of Postpartum Women With Cold-Hypersensitivity)

  • 이미주;이창훈;이경섭
    • 대한한방체열의학회지
    • /
    • 제9권1호
    • /
    • pp.22-28
    • /
    • 2011
  • Purpose :To analyze body composition in postpartum women with cold-hypersensitivity, their edema index, skelectal muscle's weight and body fat were measured and analyzed with cold hypersensitive postpartum women compared with those of non-cold hypersensitivity. Methods : We studied 38 postpartum women visiting Gangnam Kyung-Hee Korean Hospital from 1 st October 2010 to 30th september 2011. they were subjected to Digital Infrared Thermal Imaging and those with thermal difference greater than $0.3^{\circ}C$ between anterior forearm and center of hand were diagnosed with cold hypersensitivity. Cold hypersensitivity group were consisted of 11 women, the other were consisted of 26 women. All of them were measured Edema index, skelectal muscle's weight and body fat by Inbody720(body composition scanner). We studied the difference of Body composition factor between two groups and relationship between cold-hypersensitivity, Edema index, skelectal muscle's weight and body fat by Independent Samples T-test and Spearman Correlation. Results : No significant differences were observed in edema index, skelectal muscle's weight and body fat between two groups. Conclusion : There was no significant relationship among the Cold-hypersensitivity and Body composition factor(Edema index, skelectal muscle's weight. body fat). But furthemore large scale study is required.

  • PDF

HVDC용 LSR/Nano Silica Composites의 IPT특성 연구 (Study on IPT Characteristics of LSR / Nano Silica Composites for HVDC)

  • 박재준
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.61-68
    • /
    • 2019
  • Only the power is converted from AC to DC, in accordance with IEC 60587 based test method, in order to develop the LSR(Liquid Silicone Rubber) insulator material for HVDC, the experiment of Inclined Plate Tracking and Erosion Resistance was conducted. A contaminant (2.5 mS/cm: ammonium chloride) was applied at a rate of 0.3 ml/min and a voltage of ${\pm}3.5kV$, and was evaluated on the basis of 60 mA/2s. The samples were prepared by dispersing LSR/Nano silica_25wt% Composites in LSR. The erosion phenomena of surface discharge and tracking due to DC polarity and negative polarity were measured by image, leakage current maximum and thermal camera. The thermal imaging camera measured the surface temperature generated by the joule heat of the leakage current due to the drying discharge and the conductive current. After the measurement, the tracking and erosion mechanisms were evaluated for erosion weight, erosion depth and erosion length. Positive and negative polarity of LSR/Nano Silica_25wt% composite Tracking and erosion results show that positive polarity is more severe than negative polarity.

Optomechanical Design and Structural Analysis of Linear Astigmatism Free - Three Mirror System Telescope for CubeSat and Unmanned Aerial Vehicle

  • Han, Jimin;Lee, Sunwoo;Park, Woojin;Moon, Bongkon;Kim, Geon Hee;Lee, Dae-Hee;Kim, Dae Wook;Pak, Soojong
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.38.3-38.3
    • /
    • 2021
  • We are developing an optomechanical design of infrared telescope for the CubeSat and Unmanned Aerial Vehicle (UAV) which adapts the Linear Astigmatism Free- Three Mirror System in the confocal off-axis condition. The small entrance pupil (diameter of 40 mm) and the fast telescope (f-number of 1.9) can survey large areas. The telescope structure consists of three mirror modules and a sensor module, which are assembled on the base frame. The mirror structure has duplex layers to minimize a surface deformation and physical size of a mirror mount. All the optomechanical parts and three freeform mirrors are made from the same material, i.e., aluminum 6061-T6. The Coefficient of Thermal Expansion matching single material structure makes the imaging performance to be independent of the thermal expansion. We investigated structural characteristics against external loads through Finite Element Analysis. We confirmed the mirror surface distortion by the gravity and screw tightening, and the overall contraction/expansion following the external temperature environment change (from -30℃ to +30℃).

  • PDF

Short-range sensing for fruit tree water stress detection and monitoring in orchards: a review

  • Sumaiya Islam;Md Nasim Reza;Shahriar Ahmed;Md Shaha Nur Kabir;Sun-Ok Chung;Heetae Kim
    • 농업과학연구
    • /
    • 제50권4호
    • /
    • pp.883-902
    • /
    • 2023
  • Water is critical to the health and productivity of fruit trees. Efficient monitoring of water stress is essential for optimizing irrigation practices and ensuring sustainable fruit production. Short-range sensing can be reliable, rapid, inexpensive, and used for applications based on well-developed and validated algorithms. This paper reviews the recent advancement in fruit tree water stress detection via short-range sensing, which can be used for irrigation scheduling in orchards. Thermal imagery, near-infrared, and shortwave infrared methods are widely used for crop water stress detection. This review also presents research demonstrating the efficacy of short-range sensing in detecting water stress indicators in different fruit tree species. These indicators include changes in leaf temperature, stomatal conductance, chlorophyll content, and canopy reflectance. Short-range sensing enables precision irrigation strategies by utilizing real-time data to customize water applications for individual fruit trees or specific orchard areas. This approach leads to benefits, such as water conservation, optimized resource utilization, and improved fruit quality and yield. Short-range sensing shows great promise for potentially changing water stress monitoring in fruit trees. It could become a useful tool for effective fruit tree water stress management through continued research and development.

합곡(合谷)(LI4) 자침(刺鍼)이 합곡(合谷)(LI4)과 천추(天樞)(ST25) 영역(領域) 온도변화(溫度變化)에 미치는 영향(影響) (Effects on the Thermal Changes of Hap-Kok(LI4) and Chun-Choo(ST25) Following Acupuncture on Hap-Kok(LI4) in Man)

  • 손인철;김동민;김재효;김경식;이호섭
    • 대한한의학회지
    • /
    • 제19권1호
    • /
    • pp.66-88
    • /
    • 1998
  • This study was performed from March to September 1997 on 95 healthy students to observe the effects of acupuncture at Hap-kok (LI4) according to the meridian and qi-xue(氣血) phenomenon of oriental medicine's theory. Skin temperature on the Hap-kok (LI4) and Chun-Choo (ST25) were measured by D. 1. T. I. (Digital Infrared Thermograph Imaging) before acupuncture stimulation and 1min, 10 min after acupuncture stimulation. 1. In healthy students, the left and right mean temperature of LI4 and ST25 was $29.04\;^{\circ}C,\;29.12\;^{\cir}C\;and\;30.29\;^{\circ}C,\;30.22\;^{\circ}C$ respectively. 2. In control group, the time dependent changes for 10 min of LI4 and ST25 were $-0.32\;^{\circ}C,\;-0.36\;^{\circ}C\;and\;-0.5\;^{\circ}C,\;-0.46\;^{\circ}C$ respectively, however, the thermal differences of both sides LI4 and ST25 were not changed for 10 min. 3. In acupuncture stimulation of both sides LI4, the time dependent changes of ST25 were $-0.13\;^{\circ}C,\;-0.06\;^{\circ}C$, and the thermal differences of both sides ST25 were reduced, but not changed significantly. In acupuncture stimulation of right side LI4, the time dependent changes of LI4 were $-0.1\;^{\circ}C,\;-0.32\;^{\circ}C$ respectively, and the thermal differences of both sides LI4 were increased more than control, but not significantly. Also, that of ST25 were changed by $-0.69\;^{\circ}C,\;-0.63\;^{\circ}C$ respectively, but not significantly. 4. In acupuncture stimulation group, it was classified following the thermal differences of both sides LI4 and ST25, and the effects of acupuncture were observed by changes of classification. The acupuncture of both sides LI4 results in temperature of the left side ST25 to be high after acupuncture. The acupuncture of right side LI4 results in increased ratio of the left side higher than right LI4. The above results indicates that D. I. T. I. was a useful method to observe follow-up the effects and changes by acupuncture stimulation on objective evaluation of phenomenon for the meridian system. Thus, acupuncture on LI4 affects to thermal changes of ST25 and LI4, but exact examination of thermal changes on ST25 will have to be.

  • PDF

주기적으로 작동하는 위성부품 열제어용 열적완충질량과 이를 대체할 상변화물질을 이용한 열제어부품의 비교연구 (Study on the Thermal Buffer Mass and Phase Change Material for Thermal Control of the Periodically Working Satellite Component)

  • 김택영;서정기;현범석;전형열;이장준
    • 한국항공우주학회지
    • /
    • 제42권12호
    • /
    • pp.1013-1019
    • /
    • 2014
  • 저궤도 관측위성에 탑재된 영상처리장치의 온도제어를 위하여 사용하는 열적완충질량을 대체할 수 있는 상변화물질의 성능에 대하여 수치해석적으로 분석하였다. 관측위성에 사용되는 고정밀 영상처리장치는 임무에 따라 주기적으로 작동하며 발열량이 매우 큰 반면, 온도에 민감하여 작동허용 온도범위가 매우 좁다. 이러한 장치의 온도를 제어하기 위하여 국산 저궤도 관측위성에서는 열적완충질량을 이용하여 부품의 온도변화 시상수를 증가시키는 효율적인 설계를 적용하였지만, 질량이 증가하는 단점이 있다. 본 연구에서는 질량을 최소화하며 부품 온도를 안정적으로 유지할 수 있도록 고상-액상 상변화물질을 이용한 열제어 장치를 제안하였으며, 수치해석을 통하여 열적 완충질량에 대한 유효성을 비교/검증하였다. 상변화물질을 이용한 열제어 장치는 열적완충질량을 대체하여 효과적인 온도제어가 가능할 뿐 아니라 질량도 열적완충질량의 약 12% 정도로 감소시킬 수 있었다.

열 유동해석을 통한 무선충전기 발열 성능 향상에 관한 연구 (A Study on the Thermal Flow Analysis for Heat Performance Improvement of a Wireless Power Charger)

  • 김평준;박동규
    • 한국산학기술학회논문지
    • /
    • 제20권7호
    • /
    • pp.310-316
    • /
    • 2019
  • 자동차 편의 장치에 대하여 고객들은 높은 효율과 많은 기능을 요구하고 있으며, 이러한 자동차 어플리케이션에 대한 수요가 지속적으로 증가하고 있다. 본 연구에서는 최근 자동차 편의 사양으로 개발된 무선충전기의 PCB(printed circuit board) 발열 성능 향상을 위한 열 유동해석에 관한 연구를 진행하였다. 무선충전기는 PCB의 전력 손실 및 열 저항의 특성 발열에 따라 충전의 성능이 급격히 저하된다. 따라서 열 유동해석 시뮬레이션을 통해 최적의 PCB 설계 및 부품의 실장 위치를 제안하고, 각 설계 단계에서 해석을 통해 디자인을 결정한다. 이후, 실제 환경 조건에서 해석결과 정합성 검증을 위해 시험을 수행하고 결과를 비교 분석한다. 본 논문에서는 HyperLynx Thermal와 FloTHERM 프로그램을 사용하여 PCB 모델링 및 과도 응답 열 유동해석을 수행하였다. 또한, 해석 및 측정 결과의 정합성 검증을 위해 적외선 열화상 카메라를 사용하여 시험을 진행하였다. 최종 결과 비교에서 해석과 시험의 오차는 10 % 이내로 확인되었고, PCB의 발열 성능도 향상되었다.

적외선 체열촬영을 이용한 Bell's Palsy 환자의 임상적 활용 연구 (Study on the Clinical Application of Acupoints in Bell's Palsy Patients by Using of DITI)

  • 장선희;김정은;박재흥;노주환;최한나;안창범;장경전;윤현민;송춘호;홍상훈;김철홍
    • Journal of Acupuncture Research
    • /
    • 제26권6호
    • /
    • pp.141-149
    • /
    • 2009
  • Objectives : The purpose of this study is to find out proper method for clinical application of acupoints in Bell's palsy patients by using of digital infrared thermographic imaging(DITI). Methods : We investigated 44 cases of patients with Bell's palsy and checked thermal differences between abnormal and normal acupoint sites by using of DITI. Then we drew a comparison between acupoints of DITI and HBGS, ENoG, NET. We used Pearson's correlation for statistical analysis. Results : The HBGS was significantly correlated with ENoG, NET. The thermal difference of ST3 was significantly correlated with HBGS, Lip and Buccal abnormal site of NET. And the thermal differences between ST3 and GB21 were significantly correlated with ENoG, Forehead abnormal site of NET. Conclusions : Severity of Bell's palsy can be evaluated through DITI.

  • PDF

적외선 체열 촬영을 이용한 중풍(中風) 편마비(片痲痺) 환자(患者)의 합곡혈(合谷穴) 일반 자침시(刺針時)와 심자시(深刺時) 피부온도변화(皮膚溫度變化) 관찰(觀察) (Thermographic Study on the Effects of Deep Acupuncture at Hapkok(LI4) in Cerebrovascular Hemiplegia)

  • 박영철;채진석;엄재용;송성세;최익선
    • Journal of Acupuncture Research
    • /
    • 제20권4호
    • /
    • pp.134-144
    • /
    • 2003
  • Objective : This study designed to find out the effects of deep acupuncture in cerebrovascular hemiplegia. Methods : This study was performed on 30 patients with cerebrovascular hemiplegia to observe difference in temperature of skin surface between general acupuncture and deep acupuncture at Hapkok using digital infrared thermographic imaging(D.I.T.I.) Results : 1. Temperature of paralytic side is sigficantly higer $0.39{\pm}0.78^{\circ}C$ than that of contralateral side. 2. Thermal difference(${\Delta}T$) of paralytic side-contralateral side decreased $0.08{\pm}0.53^{\circ}C$ after general acupuncture, but there is no significant. $0.20{\pm}0.50^{\circ}C$ after deep acupuncture decreased significantly. So deep acupuncture is more effective than general acupuncture. 3. Thermal difference of paralytic side-paralytic side and contralateral side-contralateral side decreased significantly after acupuncture, and thermal difference of deep acupuncture on paralytic side-paralytic side decreased $0.42{\pm}1.07^{\circ}C$ more than that of general acupuncture. So deep acupuncture is more effective than general acupuncture. Conclusions: This study showed that deep acupuncture is more effective than general acupuncture In cerebrovascular hemiplegia, and further study is needed on clinical trials.

  • PDF