• Title/Summary/Keyword: thermal imaging

Search Result 626, Processing Time 0.027 seconds

Nucleic Acid Aptamers: New Methods for Selection, Stabilization, and Application in Biomedical Science

  • Kong, Hoon Young;Byun, Jonghoe
    • Biomolecules & Therapeutics
    • /
    • v.21 no.6
    • /
    • pp.423-434
    • /
    • 2013
  • The adoption of oligonucleotide aptamer is well on the rise, serving an ever increasing demand for versatility in biomedical field. Through the SELEX (Systematic Evolution of Ligands by EXponential enrichment), aptamer that can bind to specific target with high affinity and specificity can be obtained. Aptamers are single-stranded nucleic acid molecules that can fold into complex three-dimensional structures, forming binding pockets and clefts for the specific recognition and tight binding of any given molecular target. Recently, aptamers have attracted much attention because they not only have all of the advantages of antibodies, but also have unique merits such as thermal stability, ease of synthesis, reversibility, and little immunogenicity. The advent of novel technologies is revolutionizing aptamer applications. Aptamers can be easily modified by various chemical reactions to introduce functional groups and/or nucleotide extensions. They can also be conjugated to therapeutic molecules such as drugs, drug containing carriers, toxins, or photosensitizers. Here, we discuss new SELEX strategies and stabilization methods as well as applications in drug delivery and molecular imaging.

Soundness Evaluation of 120W LED Lighting using Passive Infrared Thermal Imaging Method (수동적 적외선 열화상 기법을 적용한 120W급 LED조명등 건전성 평가)

  • Jung, Yoon-Soo;Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.140-146
    • /
    • 2017
  • As energy conservation and environmental issues are emerging as a hot topic around the world, consumers are demanding high-efficiency, eco-friendly products. In this study, the author proposed 120W LED lighting system that replace metal halide lamp (MHL) which is currently used in the industry. Furthermore, it would be possible to provide a perfect opportunity for Korea to rise as a global leader in the LED lighting industry through soundness evaluation of the LED lighting system that is applied.

BRIEF REPORTS ON KAISTSAT-4 MISSION ANALYSIS

  • Seon, J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • Five scientific instruments are planned on KAISTSAT-4 that is scheduled to be launched in 2002. A far ultra-violet imaging spectrograph and a set of space plasma instruments are currently being designed. The imaging spectrograph will make observations of astronomical objects and Earth's upper atmosphere. The plasma instrumentation is capable of fast measuring the thermal magnetosphere plasmas, cold ionospheric plasmas and the Earth's magnetic fields. Major system drivers and constraints on the payloads as well as the spacecraft are identified. A preliminary analysis of the K-4 mission has been undertaken with the system requirements that are derived from the system drivers. Detailed investigation shows that Sun-synchronous orbits with approximate altitudes of 800km are optimal to satisfy the identified requirements. Comparisons with other orbits of different inclinations are also shown. Four operation modes and a daily schedule of spacecraft maneuver are found from the Sun-synchronous orbital model. It is shown that the scientific objectives of K-4 can be achieved with moderate levels of design and operation risks.

  • PDF

Development of Fast Imaging Solar Spectrograph and Observation of the Solar Chromosphere

  • Park, Hyung-Min
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.80.1-80.1
    • /
    • 2011
  • It is well known that chromospheric features are fine structured, short lived, and dynamic. Spectrograph-based observation have obvious advantage of getting physical properties of solar chromosphere than filter-based one. We developed and installed Fast Imaging Solar Spectrograph (FISS) attached on New Solar Telescope in Big Bear Solar Observatory. FISS have capabilities to take data with high time, spatial and spectral resolution at two wavelengths(Ha $6563{\AA}$ and CaII $8542{\AA}$) simultaneously. After FISS installation, we observed various chromospheric features : active regions, quiet regions, filaments/prominences and so on. As one of chromospheric studies, we analyzed solar prominences and got physical parameters by using simple radiative transfer modeling. The ranges of temperature and non-thermal velocities are found to be 7500-13000K and 5-11km/s, respectively.

  • PDF

A Study on Thermal Effect and Medication Compliance of Red Ginseng Extract (홍삼의 온열 효과와 복약 순응도에 관한 연구)

  • Choi, Min-Sun;Jeong, Jae-Cheol;Park, Jang-Kyung;Ahn, Hong-Yeop;Kim, Dong-Il
    • Journal of Oriental Medical Thermology
    • /
    • v.7 no.1
    • /
    • pp.44-54
    • /
    • 2009
  • Purpose: To evaluate thermal effect and medication compliance of red ginseng extract. Methods: Randomized, double-blind, placebo-controlled, cross-over clinical study was performed. Twenty four healthy, married women aged 30-45 years with FSFI score below 25 were randomly divided into two groups; red ginseng group(N=12) and placebo group(N=12). During the first 6-week period (Study1), each group was dosed with red ginseng or placebo twice a day. Before starting the second 6-week period(Study2), a crossover design was chosen with a 2-week break(Washout period). Interchanging two groups after Washout period, red ginseng and placebo were dosed to each group. The efficacy of thermal effect was measured with subjective warm sensation scale and lower abdomen temperature by Digital Infrared Thermographic imaging(DITI) before and after each 6-week period. A medication compliance was assessed after each 6-week period and the correlation medication compliance between Sasang Constitution and subjective warm sensation was analyzed. Results: Overall 23 participants completed the study. In subjective warm sensation scale, after taking placebo, all participants exhibited an improving trend, but there was no significant difference. In lower abdomen temperature by DITI, statistically significant objective thermal effect of red ginseng was also not shown. A medication compliance was higher in Yin constitution(Taeumin, Soeumin), and showed an upward trend with decreasing subjective warm sensation. But no statistically significant difference was exhibited. Conclusion: Statistically significant thermal effect of red ginseng was not shown in this study. We anticipate if a long-term clinical trial is practiced, significant thermal effect of red ginseng will be shown.

  • PDF

Development of Calibration Target for Infrared Thermal Imaging Camera (적외선 열화상 카메라용 캘리브레이션 타겟 개발)

  • Kim, Su Un;Choi, Man Yong;Park, Jeong Hak;Shin, Kwang Yong;Lee, Eui Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.248-253
    • /
    • 2014
  • Camera calibration is an indispensable process for improving measurement accuracy in industry fields such as machine vision. However, existing calibration cannot be applied to the calibration of mid-wave and long-wave infrared cameras. Recently, with the growing use of infrared thermal cameras that can measure defects from thermal properties, development of an applicable calibration target has become necessary. Thus, based on heat conduction analysis using finite element analysis, we developed a calibration target that can be used with both existing visible cameras and infrared thermal cameras, by implementing optimal design conditions, with consideration of factors such as thermal conductivity and emissivity, colors and materials. We performed comparative experiments on calibration target images from infrared thermal cameras and visible cameras. The results demonstrated the effectiveness of the proposed calibration target.

Clinical Study of Bell's Palsy with DITI and Nerve Conduction Test(EN0G and EMG) (DITI 및 전기신경전도검사(EN0G 및 EMG)를 이용한 구안와사(Bell's palsy) 환자에 대한 임상적 고찰)

  • Kim, Jin-man;Hong, Chul-hee;Du, In-sun;Hwang, Chung-yeon;Kim, Nam-kwen;Park, Min-chul;Lee, Sang-kwan;Jung, Sang-su;Yoon, Jun-chul
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.2
    • /
    • pp.189-211
    • /
    • 2003
  • The clinical data and thermographic imaging were analyzed on the 38 cases of Bell's palsy who were treated admission in the Oriental Medicine Hospital of Wonkwang University from January 2002 to May 2003. 38 patients with Bell's palsy were within one week after the onset of the paralysis, and thermal type in the DITI were hypo or hyper generally. Nerve conduction test(ENOG and EMG) examined in two weeks after onset. We studied interaction effect between thermal type and paralysis grade on admission day. We studied each main effect ; paralysis grade on admission day - nerve conduction test, nerve conduction test - thermal type, thermal type - paralysis grade after 4 weeks, paralysis grade on admission day - paralysis grade after 4 weeks, sasang constitution - nerve conduction test. The following results were obtained that interaction effect between thermal type and paralysis grade on admission day showed no significance, each main effect ; paralysis grade on admission day - nerve conduction test, paralysis grade on admission day - paralysis grade after 4 weeks, showed significance, each main effect ; nerve conduction test - thermal type, thermal type - paralysis grade after 4 weeks, sasang constitution - nerve conduction test, showed no significance.

  • PDF

Changes in facial surface temperature of laying hens under different thermal conditions

  • Kim, Na Yeon;Kim, Seong Jin;Oh, Mirae;Jang, Se Young;Moon, Sang Ho
    • Animal Bioscience
    • /
    • v.34 no.7
    • /
    • pp.1235-1242
    • /
    • 2021
  • Objective: The purpose of this study was to identify through infrared thermal imaging technology the facial surface temperature (FST) of laying hens in response to the variations in their thermal environment, and to identify the regional differences in FST to determine the most stable and reliable facial regions for monitoring of thermoregulatory status in chickens. Methods: Thirty Hy-Line Brown hens (25-week-old) were sequentially exposed to three different thermal conditions; optimal (OT, 22℃±2℃), low (LT, 10℃±4℃), and high temperature (HT, 30℃±2℃). The mean values of FST in five facial regions including around the eyes, earlobes, wattles, beak and nose, and comb were recorded through infrared thermography. The maximum FST (MFST) was also identified among the five face-selective regions, and its relationship with temperature-humidity index (THI) was established to identify the range of MFST in response to the variations in their thermal environment. Results: Hens exposed to OT condition at 15:00 displayed a higher temperature at wattles and around the eyes compared to other regions (p<0.001). However, under LT condition at 05:00 to 08:00, around the eyes surface temperature showed the highest value (p<0.01). In HT, wattles temperature tended to show the highest temperature over almost time intervals. Main distribution regions of MFST were wattles (63.3%) and around the eyes (16.7%) in OT, around the eyes (50%) in LT, and wattles (62.2%) and comb (18.3%) in HT. The regression equation between MFST and THI was estimated as MFST = 35.37+0.2383×THI (R2 = 0.44; p<0.001). Conclusion: The FST and the frequency of MFST in each facial region of laying hens responded sensitively to the variations in the thermal environment. The findings of this experiment provide useful information about the effect of the thermal conditions on the specific facial regions, thus offering an opportunity to stress and welfare assessment in poultry research and industry.

A Study on Thermal Effect and Medication Compliance of Red Ginseng Extract (홍삼의 온열 효과와 복약 순응도에 관한 연구)

  • Choi, Min-Sun;Jeong, Jae-Cheol;Park, Jang-Kyung;Ahn, Hong-Yeop;Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.3
    • /
    • pp.223-235
    • /
    • 2009
  • Purpose: To evaluate thermal effect and medication compliance of red ginseng extract. Methods: Randomized, double-blind, placebo-controlled, cross-over clinical study was performed. Twenty four healthy, married women aged 30-45 years with FSFI score below 25 were randomly divided into two groups; red ginseng group(N=12) and placebo group(N=12). During the first 6-week period (Study1), each group was dosed with red ginseng or placebo twice a day. Before starting the second 6-week period(Study2), a crossover design was chosen with a 2-week break(Washout period). Interchanging two groups after Washout period, red ginseng and placebo were dosed to each group. The efficacy of thermal effect was measured with subjective warm sensation scale and lower abdomen temperature by Digital Infrared Thermographic imaging(DITI) before and after each 6-week period. A medication compliance was assessed after each 6-week period and the correlation medication compliance between Sasang Constitution and subjective warm sensation was analyzed. Results: Overall 23 participants completed the study. In subjective warm sensation scale, after taking placebo, all participants exhibited an improving trend, but there was no significant difference. In lower abdomen temperature by DITI, statistically significant objective thermal effect of red ginseng was also not shown. A medication compliance was higher in Yin constitution(Taeumin, Soeumin), and showed an upward trend with decreasing subjective warm sensation. But no statistically significant difference was exhibited. Conclusion: Statistically significant thermal effect of red ginseng was not shown in this study. We anticipate if a long-term clinical trial is practiced, significant thermal effect of red ginseng will be shown.

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.