• 제목/요약/키워드: thermal factor

Search Result 1,559, Processing Time 0.027 seconds

The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

Measurement of Stress Intensity Factor of Orthotropic Material Using SPATE (SPATE에 의한 직교이방성체의 응력확대계수 측정)

  • Hwang, Jae-Seok;Suh, Jae-Guk;Lee, Hyo-Jae;Nam, Jeong-Hwan;Rpwlands, R.E.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3224-3233
    • /
    • 1996
  • SPATE(Stress Pattern Analysis by Thermal Emission) can be effectively used to analyze the stress distribution of the orthotropic structure under the repeated load by non-contact. In this research, the measuring conception and method of stress intensity factor of orthotropic material using SPATE are suggested. The relationships between the maximum values of SPATE signal and $1/\sqrt{X'}$ (or $1/\sqrt{y'}$) are theoretically established in the vicinity of crack tip of the orthotropic material. It is certified through SPATE experiment that their linear quality is very excellent.

FATIGUE ANALYSIS OF A REACTOR PRESSURE VESSEL FOR SMART

  • Jhung, Myung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.683-688
    • /
    • 2012
  • The structural integrity of mechanical components during several transients should be assured in the design stage. This requires a fatigue analysis including thermal and stress analyses. As an example, this study performs a fatigue analysis of the reactor pressure vessel of SMART during arbitrary transients. Using heat transfer coefficients determined based on the operating environments, a transient thermal analysis is performed and the results are applied to a finite element model along with the pressure to calculate the stresses. The total stress intensity range and cumulative fatigue usage factor are investigated to determine the adequacy of the design.

Cure Behaviors of Epoxy Resin Initiated by Methylanilinium Salts as Latent Cationic Curing Agent (잠재성 양이온 경화제인 Methylanilinium염에 의해 개시된 에폭시 수지의 경화 거동)

  • 박수진;김택진;이창진;이재락;박정규
    • Polymer(Korea)
    • /
    • v.25 no.2
    • /
    • pp.168-176
    • /
    • 2001
  • The effect of novel N-crotyl-N,N-dimethyl-4-methylanilinium hexafluoroantimonate (CMH) curing agent as a thermal latent initiator on thermal behaviors, rheological properties, and thermal stability of diglycidylether of bisphenol A (DGEBA) epoxy cationic system was investigated. From DSC measurements of DGEBA/CMH system, it was shown that this system exhibits an excellent thermal latent characteristic at a given temperature. The conversion and conversion rate of DGEBA/CMH system increased with increasing the concentration of initiator, due to high activity of CMH. Rheological properties of the system were investigated under isothermal condition using a rheometer The gelation time was obtained from the analysis of storage modulus (G'), loss modulus (G"), and damping factor (tan $\delta$). As a result, the reduction of gelation time was affected by high curing temperature and concentration of CMH, resulting in high degree of network formation in cationic polymerization, due to difference of activity. The thermal stability of the cured epoxy resin was discussed in terms of the activation energy for decomposition and thermal factors determined from TGA measurements.ents.

  • PDF

Fracture time of cracked body under thermal shock (열충격하에 있는 균열체의 파괴시간)

  • 이강용;박정수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.91-98
    • /
    • 1992
  • In the research on the fracture time of soda lime silicate glass under thermal shock, it is shown that the theoretical and experimental fracture times are in good agreement, the suggested method to measure critical stress intensity factor for small three-point bending specimen is useful and the edge temperature before thermal shock on cracked side vs. crack length and fracture time are inversely proportional.

  • PDF

Determination of Thermal Shock Stress Intensity Factor for Elliptical Crack by Modified Vainshtok Weight Function Method (수정 Vainshtok 가중함수법에 의한 타원균열의 열충격 응력세기계수의 결정)

  • 이강용;김종성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.463-474
    • /
    • 1995
  • Modified Vainshtok weight function method is developed. The thermal shock stress intensity factors for elliptical surface cracks existed in the thin and thick walled cylinders are determined. The present results are compared with previous solutions and shown to be good agreement with them.

Improved Thermal, Structural and Electrical Properties of Elastic-Epoxy Blends System

  • Lee, Kyoung-Yong;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.230-235
    • /
    • 2004
  • In this paper, epoxy elasticity factors were investigated by TMA (Thermomechanical Analysis), DMTA (Dynamic Mechanical Thermal Analysis) and FESEM (Field Emission Scanning Electron Microscope) to improve toughness and reduce brittleness of existing epoxy resin. Dumbbell shaped specimens were made and tested at rates of 0, 20 and 35phr (part per hundred resins). TMA temperatures ranged from -2$0^{\circ}C$ to 20$0^{\circ}C$. Tg (glass transition temperature) of elastic epoxy was measured by thermal analysis. Also investigated were thermal expansion coefficient ($\alpha$), modulus and Tan$\delta$ (loss factor). And we analyzed structure through FESEM, could find elastic-factors of elastic epoxy that is not existing-epoxy. In addition, we measured permittivity and Tan$\delta$ for investigation of the electrical properties of elastic epoxy. Permittivity and Tan$\delta$ depend on elastomer composition. Namely, permittivity and Tan$\delta$ increase according to the elastomer contents. For experimental analysis results, 20phr was considered an excellent specimen.

Clarification of the Thermal Properties of Intumescent Paint and Suggestion of the Required Fire Protection Thickness for Steel and Composite columns (철골 및 합성기둥 내화성능 확보를 위한 내화페인트 열적 물성치 규명과 소요두께 제안)

  • Kim, Sun-Hee;Ok, Chi Yeol;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.21-29
    • /
    • 2015
  • Other countries(USA, Europe) have performed the fire resistance design of buildings by the alternative performance design methods, which are based on fire engineering theories. However, in Korea, the process on the alternative fire resistance performance design has only suggested without any applications for real steel structures. Therefore, In the case of steel structures stagnant research on refractory measures face difficulties in introducing fire resistance design. In this study, first of all, Intumescent paint was analyze the thermal properties(thermal conductivity, specific heat and density). In Sequence, using the section factor by H-standard section propose of section concrete filled steel tube and hollow. finally presents a reasonable thickness Intumescent paint takes time to target performance of the proposed cross-section steel tube.

DEVELOPMENT OF GREEN'S FUNCTION APPROACH CONSIDERING TEMPERATURE-DEPENDENT MATERIAL PROPERTIES AND ITS APPLICATION

  • Ko, Han-Ok;Jhung, Myung Jo;Choi, Jae-Boong
    • Nuclear Engineering and Technology
    • /
    • v.46 no.1
    • /
    • pp.101-108
    • /
    • 2014
  • About 40% of reactors in the world are being operated beyond design life or are approaching the end of their life cycle. During long-term operation, various degradation mechanisms occur. Fatigue caused by alternating operational stresses in terms of temperature or pressure change is an important damage mechanism in continued operation of nuclear power plants. To monitor the fatigue damage of components, Fatigue Monitoring System (FMS) has been installed. Most FMSs have used Green's Function Approach (GFA) to calculate the thermal stresses rapidly. However, if temperature-dependent material properties are used in a detailed FEM, there is a maximum peak stress discrepancy between a conventional GFA and a detailed FEM because constant material properties are used in a conventional method. Therefore, if a conventional method is used in the fatigue evaluation, thermal stresses for various operating cycles may be calculated incorrectly and it may lead to an unreliable estimation. So, in this paper, the modified GFA which can consider temperature-dependent material properties is proposed by using an artificial neural network and weight factor. To verify the proposed method, thermal stresses by the new method are compared with those by FEM. Finally, pros and cons of the new method as well as technical findings from the assessment are discussed.

The Analysis of Heat Transfer through the Multi-layered Wall of the Insulating Package

  • Choi, Seung-Jin
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.12 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • Thermal insulation is used in a variety of applications to protect temperature sensitive products from thermal damage. Several factors affect the performance of insulation packages. Among these factors, the thermal resistance of the insulating wall is the most important factor to determine the performance of the insulating package. In many cases, insulating wall consists of multi-layered structure and the heat transfer through this structure is a very complex process. In this study, an one-dimensional mathematical model, which includes all of the heat transfer principles covering conduction, convection and radiation in multi-layered structure, were developed. Based on this model, several heat transfer phenomena occurred in the air space between the layer of the insulating wall were investigated. From the simulation results, it was observed that the heat transfer through the air space between the layer were dominated by conduction and radiation and the low emissivity of the surface of each solid layer of the wall can dramatically increase the thermal resistance of the wall. For practical use, an equation was derived for the calculation of the thermal resistance of a multi-layered wall.

  • PDF