• Title/Summary/Keyword: thermal contraction

Search Result 153, Processing Time 0.024 seconds

Mechanical Behavior of $Al_2O_3$ Dispersed CFRP Hybrid Composites at Room and Cryogenic Temperature

  • Manwar Hussain;Choa, Yong-Ho;Koichi Niihara
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.390-394
    • /
    • 1999
  • Al2O3 particles were dispersed into carbon fiber reinforced epoxy composites to fabricate hybrid epoxy based composites. Interface behavior and mechanical properties of these hybrid composites were studied at room and liquid nitrogen temperature and liquid nitrogen temperature and the results were compared with the those of carbon fiber reinforced composites to investigate their applicability at room and cryogenic temperature. Young's modulus in-perpendicular to fiber direction and interlaminar shear strength at room temperature and the thermal contraction down to cryhogenic temperature were improved significantly by the addition of AL2O3 filler into the epoxy matrix. The effect of Al2O3 particle addition on mechanical properties were discussed.

  • PDF

The Effect of Barium Sulfate on the Structural Transformations in Tricalcium Silicate (3CaO.$SiO_2$의 구조전이에 미치는 $BaSO_4$의 영향)

  • 서일영;최상흘
    • Journal of the Korean Ceramic Society
    • /
    • v.11 no.2
    • /
    • pp.17-21
    • /
    • 1974
  • Miscibility of barium sulfate in tricalcium silicate was investigated by firing 3CaCO3·SiO2 mixture containing barium sulfate at 1530℃. Added amount of barium sulfate to the mixture was zero to 5 mole % with intervals of 1 mole %. Lattice parametres were also calculated. Results were as follow; 1) Dissolution of barium sulfate in tricalcium silicate does not alter the symmetry in room temperature, but influences it's polymorphic transition forms, temperatures and thermal effects; modification triclinic Ⅱ is stabilized in room temperature. 2) Barium sulfate dissolves about up to 2 mole % in tricalcium silicate and more than this amount, tricalcium silicate formation is inhibited. 3) Unit cell volume of tricalcium silicate is slightly decreased with dissolution of barium sulfate, mainly because of contraction in c axis.

  • PDF

Highly Laminated Electrospun ZnO Nanofibrous Film on the Transparent Conducting Oxide for Photovoltaic Device

  • Kim, Jinsoo;Yoon, Sanghoon;Yoo, Jung-Keun;Kim, Jongsoon;Kim, Haegyeom;Kang, Kisuk
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.68-71
    • /
    • 2012
  • The electrospinning technique is a revolutionary template-catalyst-free method that can generate 1D nanostructure with the tunability and the potential for the mass production. This approach received a great deal of attention due to its ability to give direct pathways for electrical current and has been utilized in various electronic applications. However, the delamination of inorganic electrospun film has prevented the intense utilization due to the thermal expansion/contraction during the calcination. In this study, we propose an electrical grounding method for transparent conducting oxide and electrospun nanowires to enhance the adhesion after the calcination. Then, we examined the potential of the technique on ZnO based dye-sensitized solar cells.

A Study on Pre-treatment and Performance Evaluation for Printing RFID Antenna with Conductive Paste (RFID 안테나용 전도성 프린팅을 위한 PET 직물의 최적 전처리 공정연구 및 성능평가)

  • Hong, Jinpyo;Jung, Chando;Yoon, Seokhan;Choi, Sanghyun
    • Textile Coloration and Finishing
    • /
    • v.25 no.4
    • /
    • pp.287-291
    • /
    • 2013
  • Nowadays, terms such as 'Smart Textile', 'Intelligent Textile' and 'Wearable Computing' are commonly used in everyday contexts. And radio-frequency identification (RFID) is the use of a wireless non-contact system that uses radio-frequency electromagnetic fields to transfer data from a tag attached to an object, for the purposes of automatic identification and tracking. These products are required technologies which are textile treatments, printing, ink, etc. Durability of textile substrates is an essential marker for conductive ink printing process. Especially, heat stability is important, since conductive ink should be processable (annealing, curing) at temperatures below $150^{\circ}C$. This study was application of RFID on textiles. The textile pre-treatment processes should be carried out to use RFID antenna on textiles.

Study on the design of quenching fixture in hot press forming process (핫프레스포밍 공정의 냉각치구 설계에 관한 연구)

  • Lee, K.;Kwak, E.J.;Kim, H.Y.;Lee, Gi-Dong;Park, Jong-Kyu;Suh, Chang-Hee
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.337-340
    • /
    • 2009
  • In hot press forming process, the desired high strength can be obtained through quenching process after cold forming of product. The quenching process, however, accompanies undesired distortion due to the volume change during the phase transformation as well as by thermal contraction. In this study the numerical simulation with DEFORM3D-Microstructure is used to predict the deformed shape during the quenching for the quenching fixture design.

  • PDF

A Study on the Cracking Behavior in the Welds of Ni-Cr-Fe and Ni-Fe-Cr-Mo Alloys (Ni-Cr-Fe 및 Ni-Fe-Cr-Mo계 합금의 용접부 균열특성에 관한 연구 Part II : 열영향부의 액화균열)

  • 김희봉;이창희
    • Journal of Welding and Joining
    • /
    • v.15 no.5
    • /
    • pp.46-55
    • /
    • 1997
  • This study has evaluated the liquation cracking behavior in the heat affected zone of several Ni base superalloys (Incoloy 825, Inconel 718 and Inconel 600). 304 and 310S austenitic stainless steels were also included for comparison. In addition, the mechanism of liquation cracking in the HAZ was postulated based on the extensive microstructural examinations with SEM, EDAX and TEM. The liquation cracking resistance of Ni base alloys was found to be far inferior to that of austenitic stainless steels. The liquation cracking of Incoloy 825 and Inconel 718 was believed to be closely related with the Laves-austenite(Ti rich in 825 and Nb rich in 718) and MC-austenitic eutectic phases formed along the grain boundaries by constitutional liquation and incipient melting under rapid welding thermal contraction. Further, liquation cracking resistance of the HAZ was dependent not only upon the type and amount of low melting phases but also on the grain size.

  • PDF

Dynamics Analysis of Concrete Bridges at Expansion Joints Considering Pounding (신축이음부에서 충돌을 고려한 콘크리트 교량의 동적해석)

  • Choi, Suk-Jung;Yoo, Moon-Sig;Jeon, Chan-Ki;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.176-187
    • /
    • 2001
  • Most bridges have expansion joints to accommodate thermal expansion and contraction without inducing large forces in the bridges. To evaluate the effects of earthquake-induced at expansion joints of concrete bridges, the first part of this paper deals with a collinear impact between concrete segments, which have the same cross section but different lengths. Especially, impact force, momentum, strain energy and kinetic energy are formulated in mathematically. These results are then used in the second part of this paper to simulate a realistic yet simple analysis of seismic pounding in concrete bridges. Analysis of seismic pounding in idealized concrete bridges is carried out by using a simple lumped-mass model and rationally determined values of the coefficient of restitution and the duration of impact.

  • PDF

Numerical Analysis of Fluid Flow in a Regenerative Cooling Passage (재생냉각 유로 내의 유동에 관한 수치해석)

  • 조원국
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2000
  • A computational analysis has been made on fluid flow in a regenerative cooling Passage for a reduced size liquid rocket engine to predict pressure drop and heat transfer rate in it. The contraction/expansion of the cross sectional area of the passage turn out to increases both the pressure loss and the heat transfer rate of the duct. The changes of the cross sectional area near the nozzle throat are effective to protect the throat which suffers from severe thermal load. Also given is the qualitative characteristics of the performance of the regenerative cooling system due to the variation of coolant flow rate.

  • PDF

The Standardized Methods for Improvement of Maintenance Deterioration caused by Fire damage (국제 표준화를 위한 화재이후의 유지관리 시스템 개발)

  • Kwon, Young-Jin;Koo, In-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.230-231
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

The Standardized Methods for Improvement of Maintenance and Performance Construction of Deterioration caused by Fire damage (화재피해 콘크리트의 유지관리 및 시공성능 향상을 위한 표준화방안)

  • Seo, Dong-Goo;Kim, Dong-Eun;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.16-18
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF