• 제목/요약/키워드: thermal change

검색결과 3,136건 처리시간 0.03초

배기계 내구시험 중의 온도 변화 예측을 위한 연구 (A Study on the Prediction of Temperature Change during the Thermal Fatigue Test of Exhaust Manifolds)

  • 이원근
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.29-36
    • /
    • 2003
  • Exhaust manifolds suffer from serious temperature variation during the thermal fatigue test. The spatial distribution of temperature changes at each moment. Because transient flow can not be simulated during the long period of temperature change, the simulation can not be performed by conjugate heat transfer analysis. In this study, a new procedure for transient thermal analysis is established by decoupling fluid-solid analysis. The procedure consists of (1) transient CFD calculation (2 cycles), (2) mapping heat transfer coefficient to the inner surface of solid mesh as a boundary condition of heat conduction analysis and (3) transient heat conduction analysis in the long period (30 min). The realistic temperature change can be predicted by this procedure.

Envi-Met.을 이용한 도심 대기경계층 내 확산장 변화 수치 모의 (Diffusion Simulation Using Envi-Met. in Urban Planetary Boundary Layer)

  • 최현정
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.357-371
    • /
    • 2016
  • Buildings in the city acts as a cause of distorted wind direction, wind speed, causing the stagnation of the air flow. In the recent trend of climate change can not but consider the temperature rise of the urbanization. This study was aimed to analyze the thermal comfort of planetary boundary layer in different artificial constructions areas which has a direct impact on urban climate, and estimating the warming phenomena. Envi-met model was used to consider the urban structure associated with urban growth in order to precisely determine the impact of the building on the city weather condition. The analyzed values of thermal comfort index were temperature, wind speed, horizontal and vertical turbulent diffusivity. In particular, analysis of the PPD(Predicted Percentage of Dissatisfied) represents the human thermal comfort. In this study, by adjusting the arrangement and proportion of the top floor building in the urban it was found that the inflow of the fresh air and cooling can be derived low PPD. Vertical heat flux amount of the city caused by climate change was a factor to form a high potential temperature in the city and the accumulation of cold air does not appear near the surface. Based on this, to make the city effectively respond to climate change may require a long-term restructuring of urban spatial structure and density management.

적외선 체열촬영을 이용한 요통환자의 임상적 관찰 (A Clinical Study on Patients of Low Back Pain by DITI)

  • 진재도;한무규;이정훈;이승우;한상원
    • Journal of Acupuncture Research
    • /
    • 제18권4호
    • /
    • pp.22-31
    • /
    • 2001
  • Objective : This study is designed to evaluate the correlation between the data of DITI (Digital Infrared Thermographic Imaging) and the clinical symptoms in the patients with low back pain. Methods : Among the outpatients with back pain who visited to Department of Acupunture & Moxibustion, Tae gu Oriental Hopital of Kyung San University from January 2000 to August, we selected 115 cases that examined DITI. We evaluated the correlation between the data of DITI examination and the clinical symptoms (Distribution of Sex and Age, Duration of Disease, Main Sign, Grade of Clinical Symptoms, Diagnosis according to Symptoms(辨證),) in the patients with low back pain. Results & Conclusion : 1. The thermal changes in terms of the duration of disease : The acutest period has the highest thermal change. Also, the longer the duration of disease was, the higher the termal change was. It increased in the order of the acutest period, the less acute period, and the the chronical period. 2. Thermal changes due to the main symptom : The degree of thermal change was as follows (from the highest to the lowest): first, back and knee pain, second, back and leg pain, third, back and buttock pain, fourth, numbness of leg, and fifth, back and dorsum pain. 3. Thermal changes in terms of the grade of clinical symptoms : The more servious the symptoms were, the higher the thermal change was. It was increased in the order of Gr 1, Gr 2, Gr 3, and Gr 4. 4. Thermal changes depdning on symptoms diagnosis : Chwaseom(挫閃) has the highest temperature, $0.87{\pm}0.49^{\circ}C$. 5. Thermal changes before and after treatment : Before treatment, the average thermal change was $0.83^{\circ}C$ but after treatment, it was decreased to $0.38^{\circ}C$. For the above symptoms, if DITI is used, the diagnosis is easier based on the medical history of the patient who has back pain, and the degree of pain. However, if thermal change is soly used for diagnosis, it will be hard to determine the nature of sickness. Therefore, it should be folllowed by other supplementary examination.

  • PDF

기후변화가 주암호 수온성층구조에 미치는 영향 예측 (Projection of the Climate Change Effects on the Vertical Thermal Structure of Juam Reservoir)

  • 윤성완;박관영;정세웅;강부식
    • 한국물환경학회지
    • /
    • 제30권5호
    • /
    • pp.491-502
    • /
    • 2014
  • As meteorology is the driving force for lake thermodynamics and mixing processes, the effects of climate change on the physical limnology and associated ecosystem are emerging issues. The potential impacts of climate change on the physical features of a reservoir include the heat budget and thermodynamic balance across the air-water interface, formation and stability of the thermal stratification, and the timing of turn over. In addition, the changed physical processes may result in alteration of materials and energy flow because the biogeochemical processes of a stratified waterbody is strongly associated with the thermal stability. In this study, a novel modeling framework that consists of an artificial neural network (ANN), a watershed model (SWAT), a reservoir operation model(HEC-ResSim) and a hydrodynamic and water quality model (CE-QUAL-W2) is developed for projecting the effects of climate change on the reservoir water temperature and thermal stability. The results showed that increasing air temperature will cause higher epilimnion temperatures, earlier and more persistent thermal stratification, and increased thermal stability in the future. The Schmidt stability index used to evaluate the stratification strength showed tendency to increase, implying that the climate change may have considerable impacts on the water quality and ecosystem through changing the vertical mixing characteristics of the reservoir.

열적 환경변화에 의한 공작기계의 구조적 특성 (Thermal Deformation Characteristics of the Adaptive Machine Tools under Change of Thermal Environment)

  • 이재종;이찬홍;최대봉;박현구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.1023-1027
    • /
    • 2000
  • In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to analyze the thermal characteristics under several operating conditions, experiments performed with the touch probe unit and five gap sensors on the vertical and horizontal machining centers.

  • PDF

Effect of elevated pCO2 on thermal performance of Chattonella marina and Chattonella ovata (Raphidophyceae)

  • Lim, Myeong Hwan;Lee, Chung Hyeon;Min, Juhee;Lee, Hyun-Gwan;Kim, Kwang Young
    • ALGAE
    • /
    • 제35권4호
    • /
    • pp.375-388
    • /
    • 2020
  • Ocean acidification and warming, identified as environmental concerns likely to be affected by climate change, are crucial determinants of algal growth. The ichthyotoxic raphidophytes Chattonella species are responsible for huge economic losses and environmental impact worldwide. In this study, we investigated the impact of CO2 on the thermal performance curves (TPCs) of Chattonella marina and Chattonella ovata grown under temperatures ranging from 13 to 34℃ under ambient pCO2 (350 μatm) and elevated pCO2 (950 μatm). TPCs were comparable between the species or even between pCO2 levels. With the exception of the critical thermal minimum (CTmin) for C. ovata, CTmin for C. marina and the thermal optimum (Topt) and critical thermal maximum (CTmax) for both species did not change with elevation of pCO2 levels. While CO2 enrichment increased the maximum photosynthetic rates (Pmax) up to 125% at the Totp of 30℃, specific growth rates were not significantly different under elevated pCO2 for the two species. Overall, C. ovata is likely to benefit from climate change, potentially widening its range of thermal tolerance limit in highly acidic waters and contributing to prolonged phenology of future phytoplankton assemblages in coastal waters.

Hole 구조 상변화 메모리의 전기 및 열 특성 (Electro-Thermal Characteristics of Hole-type Phase Change Memory)

  • 최홍규;장낙원;김홍승;이성환;이동영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.131-137
    • /
    • 2009
  • In this paper, we have manufactured hole type PRAM unit cell using phase change material $Ge_2Sb_2Te_5$. The phase change material $Ge_2Sb_2Te_5$ was deposited on hole of 500 nm size using sputtering method. Reset current of PRAM unit cell was confirmed by measuring R-V characteristic curve. Reset current of manufactured hole type PRAM unit cell is 15 mA, 100 ns. And electro and thermal characteristics of hole type PRAM unit cell were analyzed by 3-D finite element analysis. From simulation temperature of PRAM unit cell was $705^{\circ}C$.

2-PCM 잠열축열 시스템의 열역학적 성능 (Thermodynamic performance of 2-PCM latent heat thermal energy storage system)

  • 이세균;우정선;이재효;김한덕
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.189-199
    • /
    • 2000
  • This paper investigates the thermodynamic performance of latent heat thermal energy storage system using two phase change materials(2-PCM system). The thermodynamic merit of using 2-PCM is clear in terms of exergetic efficiency, which is substantially higher than that of 1-PCM system. Optimum phase change temperature to maximize the exergetic efficiency exists for each case. The heat transfer area ratio of high temperature storage unit, X, becomes another important parameter for 2-PCM system if the phase change temperatures of given materials are different from those of optimum conditions. It is a good approximation for X$_{opt}$ to be 0.5 when optimum phase change temperatures are used. Otherwise X$_{opt}$ is determined differently as a function of given phase change temperatures.res.

  • PDF

그린하우스 열환경 조절을 위한 파라핀계 화합물(CnH2n+2)의 잠열 축열 특성 (Latent Heat Storage Characteristics of Some Paraffins(CnH2n+2) for Thermal Environment Control of Greenhouse)

  • 송현갑;유영선
    • Journal of Biosystems Engineering
    • /
    • 제21권1호
    • /
    • pp.84-93
    • /
    • 1996
  • Several paraffins(CnH2n +2) can be used as the thermal energy storage medium because of their large amount of latent heat and their flexibility of phase change temperature. But they have not been used in the thermal energy storage system because their long term stability have not been verified. Paraffins(CnH2n+2) which the values of n are 23, 24, 26 and 28 were selected for this experimental research. And this research was peformed to apply them to the practical systems. The results were summarized as follows. (1) The increase of phase change cycles had no effect on their phase change temperatures. (2) According as the values of n increased from 23 to 28, the specific heats of paraffins(CnH2n+2) increased, and were in the range of 0.47 0.75 ㎉/$kg^circ C$. (3) Thermal conductivities of them were in the range of 0.14 0.17 W/$m^circ C$. and specific gravities of them were in the range of 765800 kg/m3. (4) The density of paraffins was in the range of 765 800 kg/$m^circ C$ , and the density of solid phase was larger than that of liquid phase. (5) When the number of phase change cycles was 1, 500 cycles, the latent heat of paraffins was 90% of the initial value.

  • PDF

Influence of the Cure Systems on Long Time Thermal Aging Behaviors of NR Composites

  • Choi, Sung-Seen;Kim, Jong-Chul;Lee, Seung-Goo;Joo, Yong-L.
    • Macromolecular Research
    • /
    • 제16권6호
    • /
    • pp.561-566
    • /
    • 2008
  • NR composites with different curing systems were aged thermally at 60, 70, 80, and $90^{\circ}C$ for 2-185 days in a convection oven, and the changes in the crosslink density were investigated as a function of the accelerated thermal aging. The overall crosslink densities increased with increasing aging time irrespective of the aging temperatures and curing systems. The changes in crosslink density were enhanced by increasing the aging temperature. The degree of the increased crosslink density was in the following order: "the conventional cure system > the semi-EV system > the EV system". For short term thermal aging, the change in crosslink density with the aging time was complicated, particularly for low temperature aging. The activation energies of the change in crosslink density with thermal aging using the conventional and semi-EV cure systems increased and then remained relatively constant with increasing aging time, whereas that of the specimen with an EV cure system tended to increase linearly. The experimental results were explained by the dissociation of the existing polysulfidic linkages and the formation of new cross links through the crosslinking-related chemicals remaining in the sample.