• 제목/요약/키워드: thermal change

검색결과 3,136건 처리시간 0.033초

주거 외부 수공간 도입에 따른 실내 온열 환경 변화 분석 (Analyzing the Change of Indoor Thermal Environment with the Introduction of the Water Space in Exterior Housing)

  • 오상목;오세규;원현성
    • 한국주거학회논문집
    • /
    • 제21권2호
    • /
    • pp.41-48
    • /
    • 2010
  • This study shows how the water space outside the housing impacts the indoor thermal environment. CFD simulation was used for this experiment to analyze the interior environment focusing on the effect of temperature control and the thermal comfort. A shape of perfect square, which creates the very basic space formation, was used and the simulation was processed looking at the size, distance, and the location of the water space. The results of the experiment are as follows. Firstly, introducing a water space with the same floor area size of the simulation model decreased the indoor temperature by 1 Celsius (3.72%). It was determined the interior environment was considered as a comfort zone when the water space was greater than 70% of the floor area. Secondly, there was not much influence to the level of thermal comfort of the interior environment when the distance to the water space from the housing was greater than 2 meters. Lastly, interpreting the location of water space, the effect of controlling the total areas' temperature was the greatest following with the surrounding of the formation. There barely was any change to the temperature considering the side and the rear of the area.

공기식 흡수기의 유동 방향에 따른 $5kW_t$급 접시형 태양열 집열기의 열성능 분석 (Thermal Performance of Air receiver with a Change of Flow direction for Dish Solar Collector)

  • 서주현;강경문;이주한;오상준;서태범
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.182-185
    • /
    • 2008
  • The thermal performance of air receiver with a change of flow direction for dish solar collector. This system is installed and operated in Incheon, Korea. The thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. Experiments are being carried out to investigate the thermal performance variation of the receivers with several design parameters such as the shape of the receiver, the flow directions and the flow rate of air. First, air flows into the upper part of the receiver, which is the opposite side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 3 exits which are located near the aperture. Second, air flows into the backside of the receiver, Which is the forward side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 1 exit. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases as expected.

  • PDF

박막 게이트 절연체 위에서 Ta-Mo 합금의 안정성 (Stability of Ta-Mo alloy on thin gate dielectric)

  • 이충근;강영섭;서현상;홍신남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.9-12
    • /
    • 2004
  • This paper investigated the stability of Ta-Mo alloy on thin gate dielectric. Ta-Mo alloy was deposited by using co-sputtering process after thermal growing of 3.4nm and 4.2nm silicon dioxide. When the sputtering power of Ta and Mo were 100W and 70W, respectively, the suitable work function for NMOS gate electrode, 4.2eV, could obtain. To prove interface thermal stability of thin film gate dielectric and Ta-Mo alloy, rapid thermal annealing was performed at $600^{\circ}C$ and $700^{\circ}C$ for 10sec in Ar ambient. The results of interface reaction were surveyed by change of silicon dioxide thickness and work function after annealing process. Also, the reliability of alloy gate and gate dielectric could be confirmed by quantity of leakage current. Ta-Mo alloy was showed low sheet resistance and thermal stability, namely, little change of gate dielectric and work function, after $700^{\circ}C$ annealing process.

  • PDF

착상조건하에서 평행 평판 열교환기의 열 및 물질전달 (Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition)

  • 이관수;이태희;김우승
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

지구온난화가 대청호 수온 및 성층구조에 미치는 영향예측 (Forecasting the Effect of Global Warming on the Water Temperature and Thermal Stratification in Daecheong Reservoir)

  • 차윤철;정세웅;윤성완
    • 환경영향평가
    • /
    • 제22권4호
    • /
    • pp.329-343
    • /
    • 2013
  • According to previous studies, the increased air temperature can lead to change of thermal stratification structure of lakes and reservoirs. The changed thermal stratification may result in alteration of materials and energy flow. The objective of this study was to predict the effect of climate change on the water temperature and stratification structure of Daecheong Reservoir, located in Geum River basin of Korea, using a three-dimensional(3D) hydrodynamic model(ELCOM). A long-term(100 years) weather data set provided by the National Institute of Meteorological Research(NIMR) was used for forcing the 3D model. The model was applied to two different hydrological conditions, dry year(2001) and normal year(2004). It means that the effect of air temperature increase was only considered. Simulation results showed that the surface water temperature of the reservoir tend to increase in the future, and the establishment of thermal stratification can occur earlier and prolonged longer. As a result of heat flux analysis, the evaporative heat loss can increase in the future than now and before. However, the convective heat loss and net long wave radiation from water surface decreased due to increased air temperature.

기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구 (Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change)

  • 윤용한;권기욱
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

올소 크레졸 노볼락 에폭시 수지 연화점 변화에 따른 에폭시 몰딩 컴파운드의 물성 변화 (The Change of Physical Properties of Epoxy Molding Compound According to the Change of Softening Point of ο-Cresol Novolac Epoxy Resin)

  • 김환건;류제홍
    • 대한화학회지
    • /
    • 제40권1호
    • /
    • pp.81-86
    • /
    • 1996
  • 반도체를 보호하기 위하여 사용하는 반도체 성형 재료로, 현재 주로 사용되고 있는 Epoxy Molding Compound(EMI)의 주성분인 올소 크레졸 노볼락 에폭시 수지의 특성과 성형 재료의 관계를 조사하기 위하여 올소 크레졸 노볼락 에폭시 수지의 분자량과 깊은 관련이 있는 수지의 연화점 변화에 따른 EMC의 물성변화를 살펴보았다. 사용된 epoxy 수지의 연화점은 각각 65.1$^{\circ}C$, 72.2$^{\circ}C$, 83.0$^{\circ}C$ 인 3종을 사용하였으며 연화점 변화에 따른 EMC의 물성변화를 살펴보기 위하여 기계적 물성으로 굴곡 강도와 굴곡탄성율을, 열적 특성 변화를 관찰하기 위하여 열팽창 계수와 열전도도 그리고 유리 전이온도를 각각 측정하였다. 그리고 성형 특성과의 관계를 살펴보기 위하여 스피랄 플로우(Spiral Flow)를 측정하였다, 연화점이 증가함에 따라 굴곡 탄성율과 유리상에서의 열팽창 계수(${\alpha}_1$), 그리고 열전도도는 거의 변화가 없었으나 유리전이온도는 연화점 증가에 따라 증가함을, 스피랄 플로우는 연화점 증가에 따라 감소함을 보여주었다. 이는 에폭시 수지의 분자량이 증가함에 따라 가교밀도가 증가하는 현상에 기인한다고 판단된다. 고무상에서의 여팽창 계수(${\alpha}_2$)와 굴곡강도의 경우는 전이점을 보여주고 있는데, 이는 수지점도 증가에 따른 충전제의 분산성에 기인한 것으로 판단된다.

  • PDF

콘크리트 포장에서 발생하는 온도피해 저감에 관한 연구 (A Study on the Reduction of Temperature Damage in Concrete Pavement)

  • 김재돈;장일영
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.305-312
    • /
    • 2023
  • 연구목적: 본 연구에서는 콘크리트 포장의 온도피해를 줄이기 위해 상변화에너지가 큰 PCM을 콘크리트에 혼입하고 이에 따른 성능테스트를 진행하였다. 연구방법:저온 및 고온에 대한 온도피해를 감소시키기 위해 4.5℃와 44℃의 상변화 온도를 가지는 캡슐형 PCM을 10%, 30%, 50% 치환하여 콘크리트에 혼입하였으며 열전대와 변온챔버를 활용하여 열성능 실험과 압축강도 실험을 진행하였다. 연구결과: 열성능 실험 결과 PCM의 혼입은 최대 25%이상의 온도저항성을 향상시키는 것으로 나타났으며 다량 치환시 높은 비열로 모든 온도에서 열저항성을 높이는 것으로 나타났다. 압축강도 실험 결과 30%이상의 치환은 압축강도를 저하시키는 결과를 나타냈으며 PCM의 상변화온도를 기준으로 큰 강도차이를 나타냈다. 결론: PCM의 혼입은 콘크리트의 열성능을 증가시키는 것으로 나타냈으며 PCM의 상변화온도 부근에서 가장 큰 열성능 증가폭을 나타냈다. 또한 가장 높은 치환율인 50% 치환에서 10%~20%의 작은 강도저하가 발생하였으므로 사용성에 큰 문제가 없을 것으로 판단되며 열성능 향상을 위해 추가적인 PCM 투입이 가능할 것으로 판단된다.

탄소섬유 복합재료의 열사이클에 의한 물성치 변화에 관한 연구 (A study for multi thermal cycle effect on mechanical property change in carbon epoxy composite)

  • 최순권;박세만;박명균
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.43-48
    • /
    • 2000
  • Composite materials have been increasingly used in automotive and aircraft industries, naturally leading to active researches on the materials. The carbon-epoxy composite is selected to study its thermal characteristics. During multiple thermal cycles composed of repeated cooling and heating variations of elastic constants are investigated to understand thermal effects on the carbon-epoxy composite. In this investigation longitudinal resonance method and flexural resonance method was used to characterize. The values of $E_1$ show small amount of increases depending on number of cycles of the thermal fatigue processes whereas values of $G_13$ do not indicate noticeable changes. Also, in cases of $E_2$ and $G_23$ their values decrease to a certain extend in initial stages after applications of thermal fatigue processes. However, the number of cycles of the applied thermal fatigue processes does not seem to affect their values.

  • PDF

중온 태양열 응용을 위해 수평 단차를 갖는 열사이펀의 열적 성능 (Thermal Performance of a Thermosiphon with a Step-Change Elevation for Medium-temperature Solar Thermal Applications)

  • 이세권;정의국;부준홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2009
  • Thermal performance of a thermosiphon for medium-temperature solar thermal application was investigated. The working fluid was Dowtherm A and the container was made of STS 316L. The thermosiphon had a outer diameter of 12.7 mm and a total length of 2 m, where the evaporator and the condenser had the same length of 0.3 m and the adiabatic section was 1.4 m. Both the evaporator and the condenser were aligned horizontal with an elevation difference of 0.18 m to utilize the gravitational force for the working-fluid return. The optimum fill charge ratio of the working fluid was investigated to obtain the maximum heat transport with the lowest thermal resistance. The maximun input thermal load was 500 W and thermal resistance was $0.60^{\circ}C/W$.

  • PDF