• 제목/요약/키워드: thermal analogy

검색결과 39건 처리시간 0.026초

Parameterized Simulation Program with Integrated Circuit Emphasis Modeling of Two-level Microbolometer

  • Han, Seung-Oh;Chun, Chang-Hwan;Han, Chang-Suk;Park, Seung-Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.270-274
    • /
    • 2011
  • This paper presents a parameterized simulation program with integrated circuit emphasis (SPICE) model of a two-level microbolometer based on negative-temperature-coefficient thin films, such as vanadium oxide or amorphous silicon. The proposed modeling begins from the electric-thermal analogy and is realized on the SPICE modeling environment. The model consists of parametric components whose parameters are material properties and physical dimensions, and can be used for the fast design study, as well as for the co-design with the readout integrated circuit. The developed model was verified by comparing the obtained results with those from finite element method simulations for three design cases. The thermal conductance and the thermal capacity, key performance parameters of a microbolometer, showed the average difference of only 4.77% and 8.65%, respectively.

고온 초전도 자속흐름 트랜지스터에 적용된 전자냉각 특성 시뮬레이션 (Characteristics Simulation of Electronics Cooling for a High-Temperature Superconducting Flux Flow Transistor Circuit)

  • 고석철;강형곤;임성훈;두호익;이종화;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1063-1066
    • /
    • 2002
  • An equivalent circuit for the superconductor flux flow transistor(SFFT) was combined with high temperature cooling device, based on the analogy between thermal and electrical variables using the high-temperature superconductor(HTS), is proposed. The device is composed of parallel weak links with a nearby magnetic control line. A model has been developed that is based on solving the equation of motion of Abrikosov vortices subject to Lorentz viscous and pinning forces as well as magnetic surface barriers. The use of thermal models the global performance of thermal cooling circuit and signal system to be checked by using electrical circuit analysis programs such as SPICE.

  • PDF

Analysis of a Wet Surface Finned-tube Evaporator of an Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.211-219
    • /
    • 2002
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. Since current procedure underpredicted the experimental sensible heat factor (SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test is necessary.

Creep of concrete at variable stresses and heating

  • Klovanych, Sergei
    • Computers and Concrete
    • /
    • 제16권6호
    • /
    • pp.897-908
    • /
    • 2015
  • This article gives analytical dependences for creep of concrete at heating, taking into account conditions of its drying. These dependences are based on the standard nonlinear theory of creep of concrete at a normal temperature and temperature-time analogy. For the description of creep at various stresses and temperatures the principle of superposition are used. All stages of model's creation are confirmed by the existing experimental data. Calculation examples are given.

아닐링법에 의한 지구물리자료의 역산 (Inversion of Geophysical Data via Simulated Annealing)

  • 김희준
    • 자원환경지질
    • /
    • 제28권3호
    • /
    • pp.305-309
    • /
    • 1995
  • There is a deep and useful connection between thermodynamics (the behavior of systems with many degrees of freedom in thermal equilibrium at a finite temperature) and combinational or continuous optimization (finding the minimum of a given multiparameter function). At the heart of the method of simulated annealing is an analogy with the way that liquids freeze and crystallize, or metals cool and anneal. This paper provides a detailed description of simulated annealing. Although computationaly intensive, when it is carefully implemented, simulated annealing is found to give superior results to more traditional methods of nonlinear optimization.

  • PDF

Modeling of a Building System and its Parameter Identification

  • Park, Herie;Martaj, Nadia;Ruellan, Marie;Bennacer, Rachid;Monmasson, Eric
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.975-983
    • /
    • 2013
  • This study proposes a low order dynamic model of a building system in order to predict thermal behavior within a building and its energy consumption. The building system includes a thermally well-insulated room and an electric heater. It is modeled by a second order lumped RC thermal network based on the thermal-electrical analogy. In order to identify unknown parameters of the model, an experimental procedure is firstly detailed. Then, the different linear parametric models (ARMA, ARX, ARMAX, BJ, and OE models) are recalled. The parameters of the parametric models are obtained by the least square approach. The obtained parameters are interpreted to the parameters of the physically based model in accordance with their relationship. Afterwards, the obtained models are implemented in Matlab/Simulink(R) and are evaluated by the mean of the sum of absolute error (MAE) and the mean of the sum of square error (MSE) with the variable of indoor temperature of the room. Quantities of electrical energy and converted thermal energy are also compared. This study will permit a further study on Model Predictive Control adapting to the proposed model in order to reduce energy consumption of the building.

고속 비행체 공기흡입관 구조설계를 위한 효율적 유체-열 통합해석 연구 (An Efficient Fluid-Thermal Integrated Analysis for Air-Intake Structure Design of a High Speed Air Vehicle)

  • 전형근;류동국;이재우;김상호
    • 한국항공운항학회지
    • /
    • 제23권3호
    • /
    • pp.8-17
    • /
    • 2015
  • In this research, low fidelity air/heat load analysis was conducted for the intake of high speed vehicle. For air/heat load calculations, aerodynamic properties at the surface and the boundary layer edge were estimated using Taylor-Maccoll equation for conical flow, shockwave relation and Prandtl-Meyer expansion equation for internal and external flow. Couette flow assumption and Reynolds analogy were used in order to calculate convective heat transfer coefficient. In order to calculate skin friction coefficient for heat transfer coefficient analysis, Van Driest method II and Reference Enthalpy method were considered. An axis symmetric SCRAMJET model was selected as a reference configuration for verifying the proper implementation of the present method. Comparison of the results using the present method and Computational Fluid Dynamic analysis showed that the present method is valuable for efficiently providing pressure and heat loads for air-intake structure design of the high speed air vehicle.

압전 작동기 LIPCA를 이용한 형상가변익 설계 및 작동구현 (Design and Demonstration of Morphing Wing Sections Using Lightweight Piezoceramic Composite Actuator (LIPCA))

  • 임상민;이상기;박훈철;윤광준;구남서
    • 한국항공우주학회지
    • /
    • 제31권10호
    • /
    • pp.34-39
    • /
    • 2003
  • 본 논문에서는 압전작동기 LIPCA를 이용하여 형상가변익을 제작하였고, 제작된 형상가변익의 작동변위에 관하여 연구를 수행하였다. 등가 열 모델링 방법과 MSC/NASTRAN으로 해석을 수행하여 압전작동기의 작동변위를 예측하였고, 이를 바탕으로 형상가변익의 설계와 제작을 수행하였다. 실험을 통해 제작된 형상가변익의 실제 작동변위는 압전세라믹의 재료 비선형성으로 인해 예측된 값보다 크게 나옴을 확인하였다. 압전작동기 LIPCA를 이용한 형상가변익은 작은 크기의 무인비행기나 초소형비행기의 조종면으로 사용될 수 있다.

Effect of Melting Pool on the Residual Stress of Welded Structures in Finite Element Analysis

  • Lee, Jang-Hyun;Hwang, Se-Yun;Yang, Yong-Sik
    • Journal of Ship and Ocean Technology
    • /
    • 제11권3호
    • /
    • pp.14-23
    • /
    • 2007
  • Welding processes cause undesirable problems, such as residual stresses and deformations due to the thermal loads imposed by local heating, melting, and cooling processes. This paper presents a computational modeling technique to simulate the Gas Metal Arc Welding (GMAW) process, emphasizing the effect of the melting bead on the residual stress distribution. Both a three-bar analogy and a three-dimensional thermo-mechanical finite element analysis are carried out in order to explain the effect. Element (de)activation, enthalpy, and adjustment of the reference temperature of thermal strain are considered with respect to the effect of the weld filler metal added to the base metal during a thermo-elastic-plastic analysis. Stress distributions obtained by the present study are compared with measured values and available data from other studies. The effect of the melting bead on the residual stress distribution is discussed and demonstrated.

Instability of Evaporation Fronts in the Interstellar Medium

  • 김정규;김웅태
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.46.2-46.2
    • /
    • 2013
  • The neutral component of the interstellar medium (ISM) is segregated into the cold neutral medium (CNM) and warm neutral medium (WNM) as a result of thermal instability. It was found that the CNM--WNM evaporation interface, across which the CNM undergoes thermal expansion, is linearly unstable to corrugational disturbances, in complete analogy with the Darrieus-Landau instability (DLI) in terrestrial flames. To explore dynamical consequences of the DLI in the ISM, we perform a linear stability analysis of the DLI including the effect of thermal conduction as well as nonlinear hydrodynamic simulations. We find that the DLI is suppressed at short length scales via heat transport. The linear growth time of the fastest growing mode is proportional to the square of the evaporation flow speed of the CNM relative to the interface and is typically >10 Myr. In the nonlinear stage, perturbations grow into cusp-like structure protruding toward the WNM, and soon reach a steady state where the evaporation rate is increased by a factor of 2 compared to the initial state. We demonstrate that the amplitude of the interface distortion and enhancement in evaporation rate are determined primarily by the density ratio between the CNM and WNM. Given quite a long growth time and highly subsonic velocities at saturation, the DLI is unlikely to play an important role in the ISM dynamics.

  • PDF