Reduction of NO Emission by Two-Stage Combustion (2단 연소에 의한 NO 배출 저감에 관한 연구)

  • 유현석;최정환;오신규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권2호
    • /
    • pp.591-596
    • /
    • 1995
  • In order to investigate the reduction of NO emissions, natural gas was fueled for two-stage combustion apparatus. NO and CO emissions were described by five variables: total air ratio, primary air ratio, secondary air injection position, secondary air injection velocity, and swirl ratio. It was mainly observed that, as the primary air ratios of 0 and 0.4 NO emission decreased with increasing the secondary air injection position and secondary air injection velocity. The effect of weak swirl on NO emission was found to be insignificant.

A Study on the Comfort and Skin Temperature on the Clothing Environment in the Taegu City during Years -Concentrated on indoor uniforms- (섬유·패션 산업 DB 구축을 위한 대구지역의 연간 피복환경내의 피부온과 쾌적성 -실내 제복을 중심으로-)

  • Ryo, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyo;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • 제1권4호
    • /
    • pp.376-386
    • /
    • 1999
  • The purpose of this study was to determine the physiological responses and the Subjective sensations of the human subjects when 10 human subjects(5 males and 5 females) were tested with selected ensembles, including the uniforms of students, industrial and bank workers. For the study, garment material and design were selected, which was mostly used in Taegu area by the survey. Thermal manikin and the human subject tests were performed. The results were as follows: 1. There was no significant difference among skin temperature of head by season and among that of breast and back by all variables, however, there was a significant difference among that of belly by gender and that of thigh and shank by season. In addition, there was no significant difference among rectal temperature by gender and season, but there was a significant difference by uniform. 2. Mean skin temperature of male subjects was significantly higher than that of female subjects. Specially in lower environmental condition, the difference got larger. 3. There was a significant difference among purse rate of subjects by uniform, but there was no significant difference among those by gender and season. There were no significant difference among maximum and minimum blood pressure by gender, uniform, and season. 4. There was a significant difference in temperature of chest among gender and uniform, and there was no significant difference in temperature of back by season. In addition, There was a significant difference in humidity of back by uniform and season but there were no significant difference in that by gender. 5. There was a significant difference in humidity sensation by gender, comfort sensation by uniform and season, but there was no significant difference thermal sensation by uniform and season. 6. For the result of regression analysis, we got the regression equations as follows: Clo=1.810 Thickness+0.525, Clo=0.475 weight+0.863.

  • PDF

Prediction of Effect on Outside Thermal Environment of Building and Green Space Arrangement by Computational Fluid Dynamic (CFD 시뮬레이션을 이용한 건축물 및 녹지배치가 외부 열환경에 미치는 영향 예측)

  • Kim, Jeong-Ho;Son, Won-Duk;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • 제21권1호
    • /
    • pp.69-81
    • /
    • 2012
  • This study forecasts changes in thermal environment and microclimate change per new building construction and assignment of green space in urban area using Computational Fluid Dynamics(CFD) simulation. The analysis studies temperature, humidity and wind speed changes in 4 different given conditions that each reflects; 1) new building construction; 2) no new building construction; 3) green spaces; and 4) no green spaces. Daily average wind speed change is studied to be; Case 2(2.3 m/s) > Case 3. The result of daily average temperate change are; Case 3($26.5^{\circ}C$) > Case 4($24.6^{\circ}C$) > Case 2($23.9^{\circ}C$). This result depicts average of $2.5^{\circ}C$ temperature rise post new building construction, and decrease of approximately $1.8^{\circ}C$ when green space is provided. Daily average absolute humidity change is analysed to be; Case 3(15.8 g/kg') > Case 4(14.1 g/kg') > Case 2(13.5 g/kg'). This also reveals that when no green spaces is provided, 2.3 g/kg' of humidity change occurs, and when green space is provided, 0.6 g/kg change occurnd 4(1.8 m/s), which leads to a conclusion that daily average wind velocity is reduced by 0.5 m/s per new building construction in a building complex.

The Photoluminescence(PL) Spectroscopy and the Photo-Darkening(PD) Effect of the Amorphous SeGe Thin Films (비정질 SeGe 박막의 PL 특성과 광흑화 효과에 관한 연구)

  • 김진우;이현용;정홍배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제15권5호
    • /
    • pp.435-440
    • /
    • 2002
  • In this study, we have investigated photo-induced changes of optical energy gap( $E_{OP)}$ and photoluminescence (PL) in amorphous ($\alpha$-) S $e_{100-x}$G $e_{x}$ (x=5, 25 and 33) thin films prepared by conventional thermal evaporation method. In the $\alpha$-S $e_{100-x}$G $e_{x}$ thin film, the $E_{OP}$ is obtained by a linear extrapolation of the ($\alpha$hν)$^{\frac{1}{2}}$ versus hν plot to the energy axis using the optical absorption coefficient ($\alpha$) calculated from the extinction coefficient k measured in the wavelength range of 290~900nm. Although the values of $\Delta$ $E_{OP}$ are very different, all films exhibit photo-induced photo-darkening (PD) effect that is a red shift of $E_{OP}$ . In particular, $\Delta$ $E_{OP}$ in $\alpha$-S $e_{75}$ G $e_{25}$ thin film exhibits the largest value (i, e., $\Delta$ $E^{OP}$ ~40meV for $\alpha$-S $e_{95}$ G $e_{5}$ , $\Delta$ $E_{OP}$ ~200meV for $\alpha$-S $e_{75}$ G $e_{25}$ , $\Delta$ $E_{OP}$ ~130meV for $\alpha$-S $e_{67}$ G $e_{33}$ ). PL spectra in $\alpha$-SeGe by hν$_{HeCd}$ have no-Stokes shift (SS) and show a tendency dependent on both composition and illumination time. We explain the energy-induced phenomena such as the PD and thermal bleaching, the native charged-defect generation and the no-SS PL, etc..the PD and thermal bleaching, the native charged-defect generation and the no-SS PL, etc..tc..

A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio (난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토)

  • SEO, JUNSUN;KIM, YOUNG-JIC;PARK, JUNKYU;LEE, CHANG-EON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제32권6호
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

Characterization of Bacillus stearothermophilue Cyclodextrin Glucanotransferase that Expressed by Saccharomyces cerevisiae (Saccharomyces cerevisiae에서 발현된 Bacillus stearothermophilus Cyclodextrin Glucanotransferase의 특성)

  • 박현이;전숭종;권현주;남수완;김한우;김광현;김병우
    • Microbiology and Biotechnology Letters
    • /
    • 제30권4호
    • /
    • pp.293-297
    • /
    • 2002
  • The cyclodextrin glucanotransferase (CGTase) gene from Bacillus stearothermophilus NO2 was expressed in Saccharomyces cerevisiae 2805 under the adhl promoter. The CGTase was purified from S. cerevisiae 2805/pVT-CGTS. The purified enzyme exhibited a optima of activity around pH 7.0 and $65^{\circ}C$. Thermal stability of the enzyme was increased fairly as compared with the CGTase of B. stearothermophilus NO2. The conversion yield of cyclodextrin (CD) and the production ratio of $\alpha$-, $\beta$,-, ${\gamma}$-CD from starch were showed similarly aspect to the CGTase of B. stearothermophilus NO2.

Assessment of Geosynthetic Properties of Rubber Reinforced Composites (고무강화 복합재료의 지반용 특성 평가)

  • Jeon, H.Y.
    • Elastomers and Composites
    • /
    • 제34권3호
    • /
    • pp.247-252
    • /
    • 1999
  • Rubber related geosynthetics(GS) as reinforcement and water barrier materials were manufactured by thermal bonding method and examined the their performance for applications to civil and environmental engineering fields. The spunbonded polyester nonwoven, fiber glass mat and fabric type geogrid of a high tenacity polyester filament were used as matrix and polyester film, elastomeric bitumen with SBS polymer and asphalt were used as reinforcements to manufacture the rubber related geosynthetics. A fiber glass mat and geogrid matrix GS showed more excellent mechanical properties and nonwoven and elastomeric bitumen matrix showed the more excellent permittivity. Softening points of rubber and asphalt mixture showed no difference and dimensional stability at high temperature, $120^{\circ}C$, represented no significant shrinkage. Resistance to ultraviolet of rubber related geosynthetics showed no visible alteration.

  • PDF

Transient cooling operation of multistage thermoelectric cooler (TEC)

  • Park, Jiho;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • 제23권3호
    • /
    • pp.55-59
    • /
    • 2021
  • A thermoelectric cooler (TEC) is promising as an alternative refrigeration technology for the sake of its inherent advantages; no-moving parts and refrigerant-free in its operation. Due to the compactness, reliability and excellence in temperature stability, TECs have been widely used for small cooling devices. In recent years, thermoelectric devices have been attractive technologies that not only serve the needs of cooling and heating applications but also meet the demand for energy by recycling waste heat. In this research paper, multistage TEC is proposed as a concept of demonstrating the idea of transient cooling technology. The key idea of transient cooling is to harnesses the thermal mass installed at the interfacial level of the stages. By storing heat temporally at the thermal mass, the multistage TEC can readily reach lower temperatures than that by a steady-state operation. The multistage TEC consists of four different sizes of thermoelectric modules and they are operated with an optimized current. Once the cold-part of the uppermost stage is reached at the no-load temperature, the current is successively supplied to the lower stages with a certain time interval; 25, 50 and 75 seconds. The results show the temperatures that can be ultimately reached at the cold-side of the lowermost stage are 197, 182 and 237 K, respectively. It can be concluded that the timing or total amount of the current fed to each thermoelectric module is the key parameter to determine the no-load temperature.

Nonlinear thermal buckling behavior of functionally graded plates using an efficient sinusoidal shear deformation theory

  • Bouiadjra, Rabbab Bachir;Bedia, E.A. Adda;Tounsi, Abdelouahed
    • Structural Engineering and Mechanics
    • /
    • 제48권4호
    • /
    • pp.547-567
    • /
    • 2013
  • Nonlinear behavior of functionally graded material (FGM) plates under thermal loads is investigated here using an efficient sinusoidal shear deformation theory. The displacement field is chosen based on assumptions that the in-plane and transverse displacements consist of bending and shear components, and the shear components of in-plane displacements give rise to the sinusoidal distribution of transverse shear stress through the thickness in such a way that shear stresses vanish on the plate surfaces. Therefore, there is no need to use shear correction factor. Unlike the conventional sinusoidal shear deformation theory, the proposed efficient sinusoidal shear deformation theory contains only four unknowns. The material is graded in the thickness direction and a simple power law based on the rule of mixture is used to estimate the effective material properties. The neutral surface position for such FGM plates is determined and the sinusoidal shear deformation theory based on exact neutral surface position is employed here. There is no stretching-bending coupling effect in the neutral surface-based formulation, and consequently, the governing equations and boundary conditions of functionally graded plates based on neutral surface have the simple forms as those of isotropic plates. The non-linear strain-displacement relations are also taken into consideration. The thermal loads are assumed as uniform, linear and non-linear temperature rises across the thickness direction. Closed-form solutions are presented to calculate the critical buckling temperature, which are useful for engineers in design. Numerical results are presented for the present efficient sinusoidal shear deformation theory, demonstrating its importance and accuracy in comparison to other theories.