• 제목/요약/키워드: thermal EMF

검색결과 13건 처리시간 0.024초

대용량 이차전지 관리 시스템용 전력형 션트저항의 열기전력 안정화 (Stabilization of Thermo Electromotive Force of Power Type Shunt Resistor for Mass Storage Secondary Battery Management System)

  • 김은민;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.376-380
    • /
    • 2017
  • In this paper, we prepared a metal alloy resistor with stable thermal electro motive force (thermal EMF) as well as a low temperature coefficient of resistance (TCR) by adjusting the manganese proportion from 3 to 12 wt% in the Cu-Mn-Ni alloy. Composition of the fabricated metal alloy was investigated using energy dispersive X-ray (EDX) analysis. The TCR of each sample was measured as 44.56, 40.54, 35.60, and 31.56 ppm for Cu-3Mn-2Ni, Cu-5Mn-2Ni, Cu-10Mn-2Ni, and Cu-12Mn-2Ni, respectively. All the resistor samples were available for the F grade (${\pm}1%$ of the allowable error of resistance) high-precision resistor. All the samples satisfied the baseline of high thermal EMF (under 3 mV at $60^{\circ}C$); however, Cu-3Mn-2Ni and Cu-5Mn-2Ni satisfied the baseline of low thermal EMF (under 0.3 mV at $25^{\circ}C$). We were thus able to design and fabricate the metal alloy resistor of Cu-3Mn-2Ni and Cu-5Mn-2Ni to have low TCR and stable thermal EMF at the same time.

Preliminary Results of Thermal Effects due to Mobile Phones

  • Sik, Yoo-Done
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.471-473
    • /
    • 2002
  • Public concerns associated with the electromagnetic field (EMF) exposures from mobile phones on human body are increased. Although studies on the effects of the EMF exposures on human have been carried out for a long time, it is not proved yet whether the EMF effect is harmful or not. Based on the scientific results by experts, EMF exposure limits have been regulated as a precautionary approach on the assumption that the EMF effect may be harmful. It is well known that absorbed EMF can be transformed into heat within biological tissues and that thermal effects are related with the specific absorption rate (SAR) distribution. However, the relative magnitude and distribution of the energies are not well defined. Although there is comprehensive information of the thermal effects, most of them come from animal and in vitro studies. Considerable efforts have been made to analyze the EMF absorption model while the actual temperature in the human body has been rarely measured. Temperature changes on the face of a healthy male volunteer were studied. A digital mobile phone of 1.8GHz was used. A digital infrared imaging system (IRIS-5000, Medicore, Seoul, Korea) was applied to take infrared pictures of the face every minute while the volunteer talked over the mobile phone for 20 minutes. The specification of the imaging system was as follows: Temperature resolution = 0.1$^{\circ}C$; Range of temperature measurement = 17~40$^{\circ}C$; Pixel size = 0.9mm ${\times}$ 0.9mm; Frame time = 2.6s; Active temperature of detector = 77$^{\circ}$K. The result showed that temperature of the ear region was increased during the phone call and the region of the temperature increase on the face was expanded as the phone call time increased. Further study is necessary to investigate the temperature rise analytically and quantitatively.

  • PDF

직류전압강하법에 의한 균열길이 측정에 미치는 도선의 위치 및 보정방법의 영향에 관한 연구 (Studies on effects of calibration methods and current lead position on the direct current potential drop method for crack length measurement)

  • 조종춘;김인수;김상식;최승주;허보영
    • 분석과학
    • /
    • 제10권4호
    • /
    • pp.300-306
    • /
    • 1997
  • 직류전압강하법을 이용한 균열길이 측정방법은 입출력 도선의 위치 및 보정방법에 큰 영향을 받는다. 본 실험에서는 CT 시편을 실제 시편보다 9배 크기로 제작하여, 입출력 도선의 위치, 열 유도 EMF 및 기준전압의 위치가 기존의 보정곡선에 미치는 영향을 연구하였다. 연구 결과 입력전류 도선의 위치가 하중선에 위치할 때, Hicks-Pickard 관계식이 매우 정확하게 a/W와 V/Vo간의 관계를 나타내었으며, 이 때 Vo값을 a/W=0.241에서 측정 또는 계산된 값을 사용하고, 열유도 EMF를 보정함으로써 더욱 정확성을 향상시킬 수 있음을 알았다. 또한 입력도선이 하중선에 위치할 때 기준전압을 CT 시편에서 일반적으로 사용되는 위치인 시편 끝 하단에서 측정할 경우, 기준전압으로 보정한 전압값은 매우 큰 오차를 나타내었다.

  • PDF

Health effects of electromagnetic fields on children

  • Moon, Jin-Hwa
    • Clinical and Experimental Pediatrics
    • /
    • 제63권11호
    • /
    • pp.422-428
    • /
    • 2020
  • In today's world, most children are exposed to various manmade electromagnetic fields (EMFs). EMFs are electromagnetic waves less than 300 GHz. A developing child's brain is vulnerable to electromagnetic radiation; thus, their caregivers' concerns about the health effects of EMFs are increasing. EMF exposure is divided into 2 categories: extremely low frequencies (ELFs; 3-3,000 Hz), involving high-voltage transmission lines and in-house wiring; and radiofrequencies (RFs; 30 kHz to 300 GHz), involving mobile phones, smart devices, base stations, WiFi, and 5G technologies. The biological effects of EMFs on humans include stimulation, thermal, and nonthermal, the latter of which is the least known. Among the various health issues related to EMFs, the most important issue is human carcinogenicity. According to the International Agency for Research on Cancer's (IARC's) evaluation of carcinogenic risks to humans, ELFs and RFs were evaluated as possible human carcinogens (Group 2B). However, the World Health Organization's (WHO's) view of EMFs remains undetermined. This article reviews the current knowledge of EMF exposure on humans, specifically children. EMF exposure sources, biological effects, current WHO and IARC opinions on carcinogenicity, and effects of EMF exposures on children will be discussed. As well-controlled EMF experiments in children are nearly impossible, scientific knowledge should be interpreted objectively. Precautionary approaches are recommended for children until the potential health effects of EMF are confirmed.

Pb Free 솔더를 사용한 솔더 접합부의 접합 강도 향상에 관한 연구 (Study on Joining Strength Improvement of Solder Joint with Pb Free Solder)

  • 신영의;김영탁
    • Journal of Welding and Joining
    • /
    • 제15권2호
    • /
    • pp.36-42
    • /
    • 1997
  • In this paper, stability of initial strength at solder joint with lead free solders, such as Sn-In (52-48%) and Sn-Ag (96.5-3.5wt%) was studied. To obtain at solder joint with high quality, it is very important to control the temperature at the interface of solder joints. It is found that the thermal EMF (electro motive force) occurs betwee lead frame and copper pad on a substrate during reflow soldering process using heated tip. As a result of control the temperature at interface of solder joints, variation of initial strength at solder joint decreases from about $\pm40%$ to $\pm20%$, and it is realized Pb free soldering process using Sn/In and Sn-Ag solder paste.

  • PDF

전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로 (Constructing Topographies of EMF Risks from Underground Power Lines)

  • 김주희
    • 과학기술학연구
    • /
    • 제19권3호
    • /
    • pp.119-166
    • /
    • 2019
  • 일상 공간을 가득 메우고 있는 다양한 종류의 전자파. 그중에서도 송전선에서 발생하는 전자파의 위험성은 고압 송전탑이 건설될 때마다 여러 차례 논란이 되었는데, 이때 대안으로 떠오른 것이 바로 송전선을 땅속에 묻는 송전선로 지중화(地中化)였다. 하지만 2014년 서울의 한 초등학교 과학 교사가 지중 송전선로 구간의 전자파 측정 결과를 환경보건 시민센터에 제보하면서, 송전선로 지중화에 대한 논의는 새로운 국면을 맞이하게 된다. 송전탑보다 지중 송전선로에서 발생하는 전자파가 더 세고, 따라서 더 유해할 수도 있다는 주장이 제기된 것이다. 이후 지중 송전선로 전자파의 위험성을 둘러싸고 벌어진 논쟁에서 환경보건시민센터와 국립환경과학원은 눈에 보이지 않는 전자파 위험의 지형을 서로 다르게 재현해냈다. 이에 본 논문은 양측이 전자파를 측정할 때 측정 지점, 측정기기, 측정 높이의 측면에서 어떤 차이를 보였으며, 나아가 측정값의 의미를 해석하고 그것을 지도나 표로 재현하는 과정에서 다양한 종류의 표준들(인체보호기준, 측정의 국제 가이드라인, 발암물질 그룹 분류)을 어떻게 동원했는지를 살펴본다. 서울의 지중 송전선로에서 발생하는 전자파를 두고 벌어진 이와 같은 위험 논쟁은 그동안 주목받지 못했던, 전자파 장기 노출의 비열적 영향에 대한 관심을 불러일으키는 것이었으며, 송전선로 지중화가 과연 전자파 문제의 해결책인지에 대해서도 의문을 갖게 하는 것이었다. 나아가 이는 송전선로 지중화율이 약 90%에 육박하는 서울이라는 공간이 안전하게 관리되는 일상 공간인지, 통제되지 않는 위험한 공간인지에 대해 상충되는 대답을 암시하는 것이기도 했다.

용존산소활량 측정용 지르코니아 갈바니 센서 (Zirconia galvani sensor for the measurement of oxygen activity)

  • 오영제
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.441-448
    • /
    • 2009
  • Magnesia partially stabilized zirconia(Mg-PSZ) solid electrolytes for an improvement of thermal shock resistance, which is suitable for the measurement of oxygen activity in a molten steel, were prepared by post-thermal aging treatment. The steelmaking oxygen sensor elements were formed by an injection molding method, sintered at $1650^{\circ}C$, and then thermal aged ranged from 1250 to $1400^{\circ}C$. Sintered density and porosity were decreased as increasing the magnesia content in a zirconia-magnesia solid solution. Fractions of cubic phase to the synthesized Mg-PSZ solid electrolytes were ranged from 13.13 to 79.54.% after post-thermal aging treatment. Very dense microstructure without voids in the grains was obtained by the post-thermal aging process. Fine tetragonal phase crystallites precipitated on the cubic surface during post-thermal aging up to $1300^{\circ}C$ improve a thermal shock resistance and reappearance of electro motive force(EMF) curve.

박막 리튬이온전도체를 이용한 전위차 CO2 가스센서 (Potentiometric CO2 gas sensor based on the thin film electrolyte of Li+ ion conductor)

  • 노효섭;최광표;송호근;박진성
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.258-264
    • /
    • 2005
  • Li+-ion conducting ($Li_{3}PO_{4}$) thin films with thickness of $0.3{\mu}m$, $0.65{\mu}$, $1.2{\mu}$ were deposited on $Al_{2}O_{3}$ substrate at room temperature by thermal evaporation. They were sintered at $700^{\circ}C$ and $800^{\circ}C$ for 2 hours, respectively. Reference electrode and sensing electrode were printed on Au-electrode by silk printing method. The EMF and the ${\Delta}EMF$/dec were increased with increasing the electrolyte thickness and sintering temperature. The sample sintered at $800^{\circ}C$ was shown a good response and recovery characteristics more than those sintered at $700^{\circ}C$. The Nernst's slop of 75 mV per decade was obtained at operating temperature of $500^{\circ}C$.

마그네시아 부분안정화 지르코니아 소결체의 특성에 미치는 열처리 효과 (Effects of Aging on Properties of MgO-Partially Stabilized Zirconia)

  • 정형진;오영제;이홍림
    • 한국세라믹학회지
    • /
    • 제24권3호
    • /
    • pp.243-250
    • /
    • 1987
  • 9mol% 의 MgO로 $1650^{\circ}C$에서 4시간 고상반응과 동시에 소결시킨 부분안정화 지르코니아 소결체(9MZ-PSZ)를 소성후 냉각중 $1200^{\circ}C$~$1400^{\circ}C$의 온도범위에서 열처리하여 이의 열분해 반응, 열충격기등 및 기전력 특성에 대하여 조사하였다. 열충격시럼 전과 후의 강도, 열팽창률, X-선 회절분석에 의한 단사정사 함률과 상전이, 밀도 및 갈바닉 전위를 측정하였으며 SEm에 의한 미세구조를 관찰하였다. 입체부근의 미소화학분석은 $1350^{\circ}C$ 열처리 시편에 한하여 EDX 로 정량하였다. 9MZ-PSZ 시편의 열처리에 의하여 입방정상의 $ZrO^{2}$는 상기 온도범위에서는 준안정-정방정상의 $ZrO^{2}$와 MgO로 열분해되는데, 이때 생성된 준안정 정방정상은 열충격 시험후의 잔류강도를 응력유기상전이 효과에 의해 증가시킨다. 또한 MgO는 입계에 연속적으로 존재하는데 이런하 MgO의 연속상을 통한 열전도롤 인하여 PSZ의 열충격 저항이 크게 향상된다. 이때 PSZ의 열분해 속도와 단사정상 함량은 열처리 온도가 $1400^{\circ}C$에서 $1200^{\circ}C$로 감소됨에 따라 증가한다. 갈바닉전의 측정결과 이상의 열처리에 의하여도 양호한 기전력 특성을 갖는 지르코니아 고체전해질을 제조할 수 있다.

  • PDF

BMS 정밀도 향상을 위한 셀 밸런싱용 션트 고정저항의 허용오차 저감 방법 (A Method of Reducing a Tolerance of a Shunt Resistor for Balance of the Battery Cell to Improve a Precision of BMS)

  • 김은민;손미라;강창룡
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1055-1061
    • /
    • 2018
  • Recently, due to the rapid development of electric vehicle and energy storage system, it is emphasized for battery management system to be needed and to be improved. BMS carries out various movement for optimization the use of the energy and safe use of secondary battery, these movement of BMS start at high wattage shunt fixed resistor which performs a function for detecting current among the BMS components. In addition, for the safe operation of secondary battery, the reliability of current voltage variation detected from shunt should be secured, and for corresponding characteristics, the quality of Temperature coefficient of resistance for BMS shunt and the quality of Thermo electromotive force all must be excellent. For these reasons, this study comes up with the stabilization plan for thermo electromotive force and temperature coefficient of resistance of BMS shunt resistor which is key to secondary battery operation.