• Title/Summary/Keyword: the standard of reference

Search Result 2,150, Processing Time 0.033 seconds

Vitamin B5 and B6 Contents in Fresh Materials and after Parboiling Treatment in Harvested Vegetables (채소류의 수확 후 원재료 및 데침 처리에 의한 비타민 B5 및 B6 함량 변화)

  • Kim, Gi-Ppeum;Ahn, Kyung-Geun;Kim, Gyeong-Ha;Hwang, Young-Sun;Kang, In-Kyu;Choi, Youngmin;Kim, Haeng-Ran;Choung, Myoung-Gun
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.172-182
    • /
    • 2016
  • This study was aimed to determine the changes in vitamin $B_5$ and $B_6$ contents compared to fresh materials after parboiling treatment of the main vegetables consumed in Korea. The specificity of accuracy and precision for vitamin $B_5$ and $B_6$ analysis method were validated using high-performance liquid chromatography (HPLC). The recovery rate of standard reference material (SRM) was excellent, and all analysis was under the control line based on the quality control chart for vitamin $B_5$ and $B_6$. The Z-score for vitamin $B_6$ in food analysis performance assessment scheme (FAPAS) proficiency test was -1.0, confirming reliability of analytical performance. The vitamin $B_5$ and $B_6$ contents in a total of 39 fresh materials and parboiled samples were analyzed. The contents of vitamin $B_5$ and $B_6$ ranged from 0.000 to 2.462 and from 0.000 to $0.127mg{\cdot}100g^{-1}$, respectively. The highest contents of vitamin $B_5$ and $B_6$ were $2.462mg{\cdot}100g^{-1}$ in fresh fatsia shoots (stem vegetables), and $0.127mg{\cdot}100g^{-1}$ in fresh spinach beet (leafy vegetables), respectively. Moreover, the vitamin $B_5$ and $B_6$ contents for parboiling treatment in most vegetables were reduced or not detected. In particular, the contents of vitamin $B_5$ in parboiled fatsia shoots and vitamin $B_6$ in parboiled yellow potato and spinach beet were decreased 20- and 4-fold compared with fresh material, respectively. These results can be used as important basic data for utilization and processing of various vegetable crops, information for dietary life, management of school meals, and national health for Koreans.

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Structural Characteristics and Anti-inflammatory Activities of Chemically Sulfated-hyaluronic Acid from Streptococcus dysgalactiae (Streptococcus dysgalactiae로부터 분리된 히알루론산과 황화된 유도체의 구조와 항염증 활성)

  • Hong, Chang-Il;Jung, Eui-Gil;Han, Kook-Il;Kim, Yong Hyun;Lee, Sung Hee;Lee, Hong Sub;Han, Man-Deuk
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.545-554
    • /
    • 2016
  • Hyaluronic acid (HA) is an important macromolecule in medical and pharmaceutical fields. HA is a natural and linear polymer composed of repeating disaccharide units of β-1, 3-N-acetyl glucosamine and β-1, 4-glucuronic acid. This work aimed to confirm the structural characteristics and anti-inflammatory activities of HA and its chemically sulfated-HA. HA was produced from a fed-batch fermentation process using Streptococcus dysgalactiae in a 5 l bioreactor. HA was isolated water-soluble form (HA-WS) and water-insoluble form (HA-WI) from culture medium, and was obtained chemically sulfated-derivative (S-HA) that resulted in a 90% yield from HA-WI. The structural features of the sulfated- HA (S-HA) were investigated by FT-IR and 1H-NMR spectroscopy. The FT-IR and NMR patterns revealed the similarity in both the FTIR spectrum as well as NMR spectrum of both reference standard and purified HA from S. dysgalactiae. The anti-inflammatory activities of HA and S-HA were examined on LPS-induced RAW 264.7 cells. S-HA was significantly inhibited production of pro-inflammatory mediators such as nitric oxide (NO) and PGE2 and the gene levels of iNOS and COX-2, which are responsible for the production of NO and PGE2, respectively. Furthermore, S-HA also suppressed the overproduction of pro-inflammatory cytokine TNF-α (<80 pg/ml) and IL-6 (<100 pg/ml) compared to that of HA-WI. The present study clearly demonstrates that HA-S exhibits anti-inflammatory activities in RAW 264.7 macrophage cells.

Development of Mixed Pesticides Containing Herbicide and Topdressing Fertilizer for Paddy Rice (벼 제초제(除草劑)와 분약비(分蘖肥) 혼합약제(混合藥劑)의 개발(開發))

  • Park, Yang-Ho;Lee, Byung-Moo;Park, Seung-Soon;Lee, In-Yong;Kim, Young-Koo;Park, Young-Sun
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.3
    • /
    • pp.279-287
    • /
    • 1994
  • To develop mixed pesticides of herbicide and topdressing fertilizer for paddy rice, twelve mixtures were formulated with combination of urea coated with different level of acrylic acid wax(AAW) and four herbicides, which were thiobencarb, pretilachlor, mefenacet + bensulfuron-methyl and mefenacet + bensulfuron-methyl + dymron, and effects of the mixtures for weed control, phytotoxicity and rice tillering were investigated in the laboratory and the field experiments. Release rates of active ingredient of herbicides in the distilled water were over 90% during 24 hours same as that of the reference herbicides. The release rates of nitrogen showed different patterns according to coated level of granular urea with acrylic acid wax. Optimum release rate of nitrogen as $NH_4-N$ was obtained by 5.5% AAW coating on urea for thiobencarb or pretilachlor mixture, and by 4.0% AAW coating on urea for mefenacet + bensulfuron-methyl or mefenacet + bensulfuron-methyl + dymron mixture. The pesticide active ingredients of the mixtures were stable, which showed $3.7{\sim}8.0%$ of degradation rate after 90 days of storage under $50^{\circ}C$. Effects on weed control of mixtures were acceptable for both annual and perennial weeds, while ACRI-M9213 mixture showed considerable phytotoxicity at double dose of standard. When treated the mixed pesticides to paddy rice, rice growth status including culm length, ear length, panicle number and polished rice yield exhibited no significant differences compared with the conventional treatment.

  • PDF

A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement (PM10 질량농도 측정을 위한 시료채취기의 비교 연구)

  • Park, Ju-Myon;Koo, Ja-Kon;Jeong, Tae-Young;Kwon, Dong-Myung;Yoo, Jong-Ik;Seo, Yong-Chil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A PM10 (aerodynamic diameter${\leq}$10 ${\mu}m$) sampler is used to quantify the potential human exposure to suspended particulate matter (PM) and to comply with the governmental regulation. This study was conducted to compare and evaluate the same PM10 cutpoint and different slopes between United States Environmental Protection Agency (USEPA) PM10 sampling criterion and American Conference of Governmental Industrial Hygienists/$Comit\acute{e}$ $Europ\acute{e}en$ de Normalization/International Organization for Standardization thoracic PM10 sampling criterion through theory and experiment. Four PM10 samplers according to the USEPA criterion and one RespiCon sampler in accordance with the thoracic PM10 criterion were used in the present study. In addition, one DustTrak monitor was used to measure real time PM10 mass concentrations. All six aerosol samplers were tested in a PM generation chamber using polydisperse fly ash. Theoretical mass concentrations were calculated by applying the measured particle size distribution characteristics (geometric mean = 6.6 ${\mu}m$, geometric standard deviation = 1.9) of fly ash to each sampling criterion. The measured mass concentrations through a chamber experiment were consistent with theoretical mass concentrations in that a RespiCon sampler with the thoracic PM10 criterion collected less PM than a PM10 sampler with the USEPA criterion. The overall chamber experiment results indicated, when a PM10 sampler was used as a reference sampler, that (1) a RespiCon sampler had a normalizing factor of 1.6, meaning that this sampler underestimated an average 60% of PM10 mass sampled from a PM10 sampler, and (2) a DustTrak real-time monitor using a PM10 inlet had a calibration factor of 2.1.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.

Evaluation of confidence for measurement of VOCs in indoor air (실내공기질 VOCs 측정의 신뢰도 평가를 위한 연구)

  • Kim, Myoung Ock;Kim, Young Lan;Hong, Suk Young;Heo, Gwi Suk;Lim, Hyun Woo;Choe, Seoung Hun;Lee, Won Suk;Han, Jin Seok;Kim, Kum Hee
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • To establishment of PT Program for Indoor air quality field that manufacture of confidential development PTMs (proficiency testing materials) and examined of proficiency testing evaluation included sampling process whether or not that is valid. Confirmation of homogeneity and stability of PTMs prepared. PTMs were confirmed to be homogeneous enough to be used as proficiency testing materials since withinbottle homogeneities of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The result of this study showed that the Robust RSD of proficiency testing for VOCs (volatile organic compounds) appeared 23~43% in concentration of 50~320 ${\mu}g/m^3$ for Method A(Distribution by adsorption in Tenax-tube of VOCs), but less 13~42% in concentration of 200~1200 ${\mu}g/m^3$, 16~31% in concentration of 100~450 ${\mu}g/m^3$ for Method B (distribution by VOCs of gas phase in 10L Tedalr bag), C (directly sampling of cylinder with high pressure) respectively. The result of this study showed that method C with sampling is most adequate to the proficiency testing for VOCs in indoor air.

Development Process and Methods of Audit and Certification Toolkit for Trustworthy Digital Records Management Agency (신뢰성 있는 전자기록관리기관 감사인증도구 개발에 관한 연구)

  • Rieh, Hae-young;Kim, Ik-han;Yim, Jin-Hee;Shim, Sungbo;Jo, YoonSun;Kim, Hyojin;Woo, Hyunmin
    • The Korean Journal of Archival Studies
    • /
    • no.25
    • /
    • pp.3-46
    • /
    • 2010
  • Digital records management is one whole system in which many social and technical elements are interacting. To maintain the trustworthiness, the repository needs periodical audit and certification. Thus, individual electronic records management agency needs toolkit that can be used to self-evaluate their trustworthiness continuously, and self-assess their atmosphere and system to recognize deficiencies. The purpose of this study is development of self-certification toolkit for repositories, which synthesized and analysed such four international standard and best practices as OAIS Reference Model(ISO 14721), TRAC, DRAMBORA, and the assessment report conducted and published by TNA/UKDA, as well as MoRe2 and current national laws and standards. As this paper describes and demonstrate the development process and the framework of this self-certification toolkit, other electronic records management agencies could follow the process and develop their own toolkit reflecting their situation, and utilize the self-assessment results in-house. As a result of this research, 12 areas for assessment were set, which include (organizational) operation management, classification system and master data management, acquisition, registration and description, storage and preservation, disposal, services, providing finding aids, system management, access control and security, monitoring/audit trail/statistics, and risk management. In each 12 area, the process map or functional charts were drawn and business functions were analyzed, and 54 'evaluation criteria', consisted of main business functional unit in each area were drawn. Under each 'evaluation criteria', 208 'specific evaluation criteria', which supposed to be implementable, measurable, and provable for self-evaluation in each area, were drawn. The audit and certification toolkit developed by this research could be used by digital repositories to conduct periodical self-assessment of the organization, which would be used to supplement any found deficiencies and be used to reflect the organizational development strategy.