• Title/Summary/Keyword: the standard of reference

Search Result 2,159, Processing Time 0.03 seconds

Speed Control for a PMSM Servo System Using Model Reference Adaptive Control and an Extended State Observer

  • Li, Xiaodi;Li, Shihua
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.549-563
    • /
    • 2014
  • In this paper, the speed regulation problem of permanent synchronous motor (PMSM) systems under the vector control framework is studied. A model reference adaptive controller (MRAC) based on the Lyapunov stability theory is first designed. Since the standard MRAC method provides poor disturbance rejection performance in the case of strong disturbances, a composite control method which combines the MRAC method and the disturbance estimation method, called the MRAC+ESO method, is proposed. An extended state observer (ESO) is introduced to estimate the lumped disturbances. The obtained estimated value acts as a feedforward compensation term to the MRAC controller. A stability analysis of the composite control method is given. Simulation and experimental results are presented and compared to show the effectiveness of the proposed control method.

A Study on the Performance Test of NA-Q Additive Oil by Using an Engine Dynamometer(Part I) - Test of the Reference Oil - (엔진 다이나모메터를 이용한 NA-Q첨가 윤활유의 성능시험 연구(제1보) - 기준 윤활유의 시험 -)

  • 정동윤;한흥구;한희동
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.347-352
    • /
    • 2000
  • Before investigating the performance of NA-Q additive oil, we have studied the properties of the commercial reference oil by using an engine dynamometer. Experimemts were conducted for 300 hours with 2,950rpm and 22kw and every 50 hours the used oil was sampled for analyzing its physical and chemical propreties. The reference oil shows stable but slightly increasing viscosities during the experiment. It has good agreements with the change of its TAN and TBN. Friction coefficients and anti-wear characteristics are compared with its ZDTP depletion factor and the diameters of wear scar. The concentrations of metal particles are analyzed with the results of ICP and spectrometer, However it is found that the concentrations by filtration method shows large difference with those by standard method in spectrometer.

  • PDF

Development of a Chloroform Reference Material for the Proficiency Testing of Hazardous Compounds in Commercial Consumer Chemical Products Under the Consumer Chemical Products and Biocide Safety Management Act (K-BPR)

  • Lee, Sang Tak;Lee, Jae-ung;Kim, Joo-Hyon;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.10 no.4
    • /
    • pp.112-116
    • /
    • 2019
  • In this study, a chloroform consumer chemical product (CCP) reference material (RM) is successfully developed, with potential to be used in the proficiency testing of hazardous compounds in CCPs for analysis and testing agencies. Validation experiments are rigorously conducted to evaluate whether the RM meets the requirements set by the ISO 13528 and ISO Guide 35, using a reliable GC/MS method for the analysis of chloroform. The obtained calibration plot linearity, limit of detection (LOD), and limit of quantitation (LOQ) are excellent. The developed RM meets the homogeneity and stability requirements; the between-unit (sbb) and within-unit (swb) standard deviations are less than 2.5%, and the stability is found to be guaranteed for 50 days.

Anthropometric and Nutrition Status of Institutional Children (사회복지시설 아동의 신체발육 및 영양상태)

  • 정혜경;장영은
    • Korean Journal of Community Nutrition
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 1999
  • This study was designed to investigate the malnutrition rate with anthropometric indices for the nutrient intake of 74 children aged 4-12 years old in three child welfare institutions in Cheonan city. The average heights and weights of the children are much lower than the Korean average height and weight. The mean BMI is $17.0{\pm}1.53$. In terms of height-for-age, 16.0% of the samples belong to below -2 standard deviation from the mean of the reference group. In terms of weight-for-age, 16.0% of the children belong to below -2 standard deviation. In terms of weight-for-height, 4.0% of the children belong to below -2 standard deviation. The standard deviation scores(Wt/Age, Ht/Age) indicate negative signs for seventy to eighty percent of the children. This is due to the lower consumption of the important nutrients that children consumed and almost all nutrients much less than the recommended daily allowances. Special nutrition welfare policies and programs targcting child welfare institutions should be developed to provide adequate nutrition for children in residential care.

  • PDF

The Environmental Load Comparison Evaluation of The Apartment House for Main Construction Materials of Standard Apartment House (표준공동주택의 주요 건설자재 설정을 통한 공동주택 환경부하 비교평가에 관한 연구)

  • Woo, Jee-Hwan;Shin, Sung-Woo
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • The study set up the models of a general standard apartment house and a super high-rise standard apartment house, which were based on the 5 floor plans of the assessment reference houses of the "green homes" provided by the government; such main construction materials as to account for more than 80% of the entire amount of $CO_2$ emission in a construction work were selected; a database was built up for evaluating the environmental loads of the main materials according to the house types that were different from each other in area, block type, combination of living units or floor; and using the database, an attempt was made to develop the technology to assess $CO_2$ emission from the production of construction materials used in the stage of construction.

The $\alhpa-\beta$ Current and Power Components of the Instantaneous Power Theory (순시전력이론의 $\alhpa-\beta$전류성분 및 $\alhpa-\beta$ 전력성분의 고찰)

  • Kim Jung-Kun;Lim Young-Cheol;Jung Young-Gook;Kim Young-Cheol;Chun Hong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.612-617
    • /
    • 2002
  • To provide beginner with the standard current information on the $\alhpa-\beta$ reference frame of nonlinear load, this paper has focused on the simulation works using MATLAB/SIMULINK in case of current source thyristor controlled rectifier The various $\alhpa-\beta$ components of current/power components are induced by the p-q theory, the results are represented waveforms and trajectories on the $\alhpa-\beta$ reference frame. The compensation effect according to each of the compensating reference components are described.

  • PDF

F.E.M for Analysis of Magnetic Circuits with thin Magnetic Materials (얇은 자성체를 갖는 자기회로의 자장해석을 위한 유한요소법)

  • Kim, Kwon-Sik;Lee, Joon-Ho;Lee, Ki-Sik;Lee, Bok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.573-576
    • /
    • 1992
  • This paper presents a method, which couples the boundary integral terms in the thin magnetic materials with standard FEM used to analyze the rest of it, for analyzing the magnetic fields. The proposed method retains the sparsity and symmetry of the final system matrix, the merits of standard FEM and eliminates the need for fininte elements in the thin magnetic materials, thereby reducing necessary capacity of computer memory and computing time. To verify the usefulness of the proposed alogorithmn, an examples, coil with source currents and thin magnetic materials, is chosen and analyzed. the results are compared with those of the standard FEM by coarse mesh and the proposed method, using standard FEM by fine mesh as a reference.

  • PDF

Fast Motion Estimation Using Multiple Reference Pictures In H.264/Avc (H.264/AVC에서 다중 참조 픽처를 이용한 고속 움직임 추정)

  • Kim, Seong-Hee;Oh, Jeong-Su
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.536-541
    • /
    • 2007
  • In video coding standard H.264/AVC, motion estimation using multiple reference pictures improves compression efficiency but the efficiency depends upon image content not the number of reference pictures. So, the motion estimation includes a large amount of computation of no worth according to image. This paper proposes fast motion estimation algorithm that removes worthless computation in the motion estimation using multiple reference pictures. The proposed algorithm classifies a block into valid and invalid blocks for the multiple reference pictures and removes the workless computation by applying a single reference picture to the invalid block. To estimate the proposed algorithm's performance, image quality, bit rate, and motion estimation time are compared with ones of the conventional algorithm in the reference software JM 9.5. The simulation results show that the proposed algorithm can considerably save about 38.67% the averaged motion estimation time while keeping the image quality and the bit rate, whose are average values are -0.02dB and -0.77% respectively, as good as the conventional algorithm.

Quantitative analysis of phosphorus by HERETIC-NMR method (HERETIC-NMR법을 이용한 인의 정량분석)

  • Lim, Heon-Sung;Park, Chan-Jo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.438-441
    • /
    • 2008
  • We have developed an alternative to the internal chemical reference based on a calibrated reference signal which is not a real NMR line but an electronically produced signal (HERETIC) and determined the phosphorus concentration using this method. The area ratio of HERETIC and sample peaks obtained from the standard samples was used to measure the concentrations of different samples directly. The analysis of phosphorus by this method showed the excellent linear regression coefficient ($R^2=0.9999$) for the concentration range from 20 ppm to 500 ppm with HERETIC peak as reference.

Architecture Design for Integration of Software RS and IM of Maritime DGPS Reference Station System (해양 DGPS 기준국 시스템의 소프트웨어 RS,IM 통합을 위한 아키텍처 설계)

  • Jang, Wonseok;Kim, Youngki;Seo, Kiyeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.282-288
    • /
    • 2014
  • The DGPS reference station is a national infrastructure generating GPS correctional information and transmitting the signal for Differential GPS. Currently, Korea has applied and operated the software-based DGPS reference station as a standard of the next generation proposed by the USCG in order to improve the hardware-based DGPS reference system. However, software-based DGPS reference station proposed by USCG was changed in software method, only for form. There is no advantage to changing software-based because the most critical part of architecture has not been improved. In this paper, we have designed a new software-based marine DGPS station architecture that a reference station software and a monitor station were integrated. The new marine DGPS station architecture based on software is a more simplified structure than it used to be and can be utilized in the DGPS reference station.