• Title/Summary/Keyword: the standard body measurement

Search Result 267, Processing Time 0.028 seconds

A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry (치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구)

  • Park, Ilwoo;Jeung, Wonkyo;Hwang, Hyungsuk;Lim, Sunghwan;Lee, Daenam;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2013
  • This study estimate radiation biological danger factor by measuring patient's exposed dose and propose the low way of patient's exposed dose in panoramic radiography. We seek correcting constant of OSL dosimeter for minimize the error of exposed dose's measurement and measure the Left, Right crystalline lens, thyroid, directly included upper, lower lips, the maxillary bone and the center of photographing that indirect included in panoramic radiography by using the human body model standard phantom advised in ICRP. In result, the center of photographing's level of radiation maximum value is $413.67{\pm}6.53{\mu}Gy$ and each upper, lower lips is $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$. Also in panoramic radiography, indirect included Left, Right crystalline lens's level of radiation are $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$, and thyroid's level of measured exposed dose can cause effect of radiation biological and we need justifiable analysis about radiation defense rule and substantiation advised international organization for the low way of patient's exposed dose in panoramic radiography of dental clinic and we judge need the additional study about radiation defense organization for protect the systematize protocol's finance and around internal organs for minimize until accepted by many people that is technological, economical and social fact by using panoramic measurement.

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.

Seasonal variation in growth of Berkshire pigs in alternative production systems

  • Park, Hyeon-Suk;Oh, Sang-Hyon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.5
    • /
    • pp.749-754
    • /
    • 2017
  • Objective: The objective of the present study was to investigate the effects of farrowing month (FM), parity and sex on the growth performance of Berkshire swine raised in alternative production systems. Methods: A total of 40 farrowing records from 27 sows and 1,258 body weight (BW) records from 274 piglets collected over a two-year period were used for the analysis. The BWs were recorded at birth, weaning (28 d), 56, 84, 112, and 140 days. Any BW not recorded on schedule was recalculated to conform the days of age among corresponding BW records, using growth curves drawn with polynomial functions whose power was determined by the number of existing observations for each individual. Results: The mean parity (${\pm}$standard deviation) of the sows was $3.42{\pm}2.14$. The sows that farrowed in June had the lowest number of total born with an average of $6.25{\pm}2.22$ piglets per sow. However, the lowest average number of piglets weaned at day 28 was found in sows that farrowed in May, as well as the highest number recorded for the stillborn piglets with an average of 2.67 piglets per sow. Moreover, the smallest increase in weight from birth to weaning occurred in piglets that were farrowed in May, which also corresponds with the average daily gain (ADG) of 0.29 kg and the last recorded weight measurement on day 140 of $41.69{\pm}1.45kg$. Contrastingly, the highest growth rate was found among pigs farrowed in June, with the largest increase in weight of 7.55 kg from birth to weaning, the highest ADG of 0.51 kg from birth to 140 day of age and the highest BW of $74.70{\pm}1.86kg$ recorded on day 140. Conclusion: Pigs farrowed in June also had the least number of piglets that died between birth and weaning. The zone of thermal comfort found in sows reared in indoor confinement systems did not improve the reproductive performance of the sows reared in an outdoor, alternative production system, while the growth performance of the piglets was improved when the ambient temperature was consistently hot or consistently cold.

Deep Learning-Based Assessment of Functional Liver Capacity Using Gadoxetic Acid-Enhanced Hepatobiliary Phase MRI

  • Hyo Jung Park;Jee Seok Yoon;Seung Soo Lee;Heung-Il Suk;Bumwoo Park;Yu Sub Sung;Seung Baek Hong;Hwaseong Ryu
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.720-731
    • /
    • 2022
  • Objective: We aimed to develop and test a deep learning algorithm (DLA) for fully automated measurement of the volume and signal intensity (SI) of the liver and spleen using gadoxetic acid-enhanced hepatobiliary phase (HBP)-magnetic resonance imaging (MRI) and to evaluate the clinical utility of DLA-assisted assessment of functional liver capacity. Materials and Methods: The DLA was developed using HBP-MRI data from 1014 patients. Using an independent test dataset (110 internal and 90 external MRI data), the segmentation performance of the DLA was measured using the Dice similarity score (DSS), and the agreement between the DLA and the ground truth for the volume and SI measurements was assessed with a Bland-Altman 95% limit of agreement (LOA). In 276 separate patients (male:female, 191:85; mean age ± standard deviation, 40 ± 15 years) who underwent hepatic resection, we evaluated the correlations between various DLA-based MRI indices, including liver volume normalized by body surface area (LVBSA), liver-to-spleen SI ratio (LSSR), MRI parameter-adjusted LSSR (aLSSR), LSSR × LVBSA, and aLSSR × LVBSA, and the indocyanine green retention rate at 15 minutes (ICG-R15), and determined the diagnostic performance of the DLA-based MRI indices to detect ICG-R15 ≥ 20%. Results: In the test dataset, the mean DSS was 0.977 for liver segmentation and 0.946 for spleen segmentation. The Bland-Altman 95% LOAs were 0.08% ± 3.70% for the liver volume, 0.20% ± 7.89% for the spleen volume, -0.02% ± 1.28% for the liver SI, and -0.01% ± 1.70% for the spleen SI. Among DLA-based MRI indices, aLSSR × LVBSA showed the strongest correlation with ICG-R15 (r = -0.54, p < 0.001), with area under receiver operating characteristic curve of 0.932 (95% confidence interval, 0.895-0.959) to diagnose ICG-R15 ≥ 20%. Conclusion: Our DLA can accurately measure the volume and SI of the liver and spleen and may be useful for assessing functional liver capacity using gadoxetic acid-enhanced HBP-MRI.

The Shape and the Location of Forehead Hairline of Korean Males in Their 20s & 30s (20, 30대 한국 남성의 전두부 모발선의 모양과 위치)

  • Yoon, Sung-Won;Kim, Chung-Hun
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.295-299
    • /
    • 2011
  • Purpose: It is generally believed that alopecia is caused by various factors such as scars, stress, genetical factors, androgens, etc. Androgenic alopecia is one of the most common cause of alopecia and found mainly in males. Propecia (Merck & Co., USA) and Minoxidil (McNEIL-PPC, Inc, USA) were the drugs approved from FDA for treatment of androgenic alopecia. Surgical treatments such as flap, tissue expansion, scalp reduction and hair transplantation can be considered if necessary. Hair micrograft techniques were developed for natural hair shapes and minimal adverse effect. There were attempts to measure the length of the forehead of the Korean young adults. However attempts to classify the shape and location of forehead hairline were rare. This study attempted to find out standard hairlines of young adults in their 20s & 30s and the result would be the guideline of the hairline in hair replacement surgery of male patients in their 40s & 50s. Methods: 200 male adults in 20s and 30s were photographed and measured the length of 11 vertical index lines to determine hairline. The indexes are the distances from hairline to intercanthal midpoint (A), to medial canthus (B), to upper eyelid fissure (C), to lower eyelid fissure (D), to lateral canthus (E) and distance from lateral highest point to medial lowest point, if the hairline is M-shape (F). Additionally, we classified the hairlines into 4 groups, M, horizontal, inverted U and irregular shapes. Results: The most common hairline of male adults in their 20s is inverted U-shape (53.3%), followed by horizontal-shape, M-shape, irregular-shape. In their 30s, inverted U-shape (59%) is followed by irregular-shape, M-shape, horizontal-shape. The M-shape is more frequently found in males in 30s than those in 20s. The mean values of the indexes in their 20s are as follows: A (76.14 mm), B (Rt: 75.78 mm, Lt:76.41 mm), C (Rt: 69.43 mm, Lt: 69.92 mm), D (Rt: 76.92 mm, Lt:77.46 mm), E (Rt: 64.16 mm, Lt: 64.73 mm), F (4.09 mm). Those in their 30s are as follows: A (76.13 mm), B (Rt: 76.114 mm, Lt: 76.02 mm), C (Rt: 69.87 mm, Lt: 70.37 mm), D (Rt: 77.37 mm, Lt: 77.58 mm), E (Rt: 69.63 mm, Lt: 69.85 mm), F (6.14 mm). Conclusion: The knowledge about human body measurement is indispensable to plastic surgeons. In this study, inverted U shape is the most common type of hairline in 30s, and similar distribution is found in 20s. The percentage of M shape in their 30s is elevated more than 10% compared to that in their 20s. The study of hairline shapes and 11 indexes of hairlines can be useful for planning of the hair transplantation and postoperative evaluation. This study being based on photogrammetry, there may be differences between actual distance of curved face and projected distance on flat photographs.

A Study on the Natural Interspecific Hybrid between Rhodeus notatus and R. ocellatus (떡납줄갱이 Rhodeus notatus와 흰줄납줄개 R. ocellatus의 자연 종간잡종에 관한 연구)

  • Yun, Bong Han;Sung, Mu Sung;Kim, Yong Hwi;Bang, In-Chul
    • Korean Journal of Ichthyology
    • /
    • v.33 no.3
    • /
    • pp.157-166
    • /
    • 2021
  • Three specimens, presumed to be natural hybrids between Rhodeus notatus and R. ocellatus, were collected from Onyangcheon Stream area, Jwabu-dong, Asan-si, Chungcheongnamdo, the Republic of Korea, and morphological and phylogenetic analyses were performed to clearly identify their parent species. The body color of the three natural hybrids was light greenish-brown on dorsal side, and the size of red area on the upper front of the dorsal fin and the outer margin of the anal fin generally showed intermediate characters between the parent species, R. notatus and R. ocellatus. Among the measurement and meristic characters, the ratio of prepectoral length and preanal length in the standard length, and the ratio of snout length, interorbital width, length of caudal peduncle and depth of caudal peduncle in the head length, and the number of longitudinal row scales were analyzed as the unique characters of natural hybrids. In the rag1 gene of nuclear DNA, the three natural hybrids were analyzed to be reflected all the single nucleotide polymorphism sites between R. notatus and R. ocellatus, and in the phylogenetic tree using the cytb gene of mitochondrial DNA, they formed the same genetic clade as R. notatus. Therefore, three specimens, presumed to be natural hybrids analyzed in this study were identified as interspecific hybrids between female R. notatus and male R. ocellatus.

The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy (방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구)

  • Yang, Seung-Woo;Han, Moo-Jae;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.789-794
    • /
    • 2021
  • Brachytherapy is a treatment in which radioactive isotopes are placed inside the body to intensively irradiate the tumor with radiation. Because brachytherapy uses a radioisotope source with a high dose rate, it is very important to know the exact location and dose of the source. However, in clinical practice, it is evaluated inaccurately with the naked eye through rulers and autoradiographs. Therefore, in this study, a dosimeter that can be used for brachytherapy was developed using a lead(II) iodide (PbI2) material, and the applicability was evaluated by analyzing the reproducibility, linearity, and PID items. As a result of reproducibility evaluation, the RSD value was 1.41%, satisfying the evaluation criteria of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the evaluation criterion of 0.9990. As a result of PID evaluation, it showed only a difference of 0.06 cm compared with the theoretical value of the inverse square law of distance at the 50% dose reduction point. The dosimeter manufactured in this experiment shows results that satisfy the standard in all evaluations, so it is judged that the possibility of applying the dosimeter in the radiation brachytherapy area is sufficient.

A Study on the Iron Nutritional Status with Biochemical Parameters in Preschool Children (어린이집을 이용하는 미취학 아동의 생화학적 분석에 의한 철분영양상태에 관한 연구)

  • Yu, Kyeone-Hee
    • Journal of Nutrition and Health
    • /
    • v.38 no.7
    • /
    • pp.533-543
    • /
    • 2005
  • The purpose of this study was to determine the iron status of preschool children in Ulsan, Korea. The study was con-ducted using 95 children aged 3 to 6 years by investigating the anthropometric indices and assessing the dietary intakes and biochemical analysis. A questionnaire for dietary intakes using 24-hr recall method were carried out by the mothers of the 95 subjects. And also a study was conducted to assess hematological and biochemical status of iron and prevalence of iron deficiency. The average height and weight were 105.4 $\pm$ 7.0 cm, 18.7 $\pm$ 3.2 kg in boys, 103.8 $\pm$ 6.7 cm, 17.6 $\pm$ 2.7 kg in girls. These were lower than the body growth standard values of Korean pediatrics. There was not a significant difference in both between boys and girls. For the daily nutrient intake, energy was 1201.5 $\pm$ 280.9 kcal (79.3$\%$RDA), protein was 63.8 $\pm$ 28.2 g (219.4$\%$RDA), iron was 11.9 $\pm$ 4.5 mg (133.2$\%$RDA). The iron nutritional status by hematological assay found that Hct was 34.7 $\pm$ 2.0 ($\%$), Hb was 12.0 $\pm$ 0.8 g/dl, RBC was 4.3 $\pm$ 0.3 ($10^6/{\mu}l$), MCV was 80.5 $\pm$ 3.0 fL, MCH was 27.8 $\pm$ 1.1 pg and MCHC was 34.6 $\pm$ 0.6 g/dl. The biochemical measurement of serum iron was 75.6 $\pm$ 30.3 ${\mu}g$/dl, TIBC was 320.3 $\pm$ 34.1 ${\mu}g$/dl, serum ferritin was 30.0 $\pm$ 14.8 ${\mu}g$/dl, Zinc-Protophor-phyrin (ZPP) was 32.7 $\pm$ 8.0 ${\mu}g$/dl, and ZPP/Heme was 71.1 $\pm$ 19.5 ($\mu$mole/mol heme). The prevalence with Hct, Hb, TS and serum ferritin less than cut-off value was $8.4\%,\;9.5\%,\;12.6\%$ and $4.4\%$ respectively. But the prevalence of iron deficiency estimated with ZPP and ZPP/Heme criteria were $25.3\%$ and $27.4\%$, and were higher than in case of any other indices. The prevalence of iron deficiency anemia ((low Hb (< 11.0 g/dl) and low serum ferritin (< 10 ${\mu}g$/L) or low TS (3-4 yews: < $12\%$, 5-6 years: < $14\%$)) was found in only one 3 year old girl. The prevalence of iron deficiency except Hct and Hb was the highest in 3 year group, but the prevalence by Hct and Hb was the highest in 5 year group. Iron deficiency and iron deficiency anemia do not seem to be a major public health problem in preschool children in Ulsan.

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.