• Title/Summary/Keyword: the standard body measurement

Search Result 268, Processing Time 0.033 seconds

Development of Multichannel On-line Thermometry System (다 채널 직결 온도측정 시스템의 설계 및 제작)

  • Shin, Sei-One;Shin, Hyun-Jin;Kim, Myung-Se;Kim, Sung-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.193-199
    • /
    • 1999
  • Background: Measurement of body temperature is an important parameter in patient management in many clinical conditions. Failure to reach minimal acceptable body temperature standards has been associated with physiological derangements and has necessitated the application of additional therapy. The authors developed a new, simple, accurate thermometry system, which could be used to undertake precise temperature measurement for various clinical conditions. Materials and Methods: A new thermometry system using a specially designed temperature detecting and display system was developed. This system contains a temperature detecting sensor(LM 35CZ), which enables multiple serial checking of heat, data collection and processing computer, and 3-dimensional display system. It provides real time volumetric visualization of temperature distribution of a defined volume and stores and prints the data. Results: With this system, temperature can be measured at multiple interesting sites simultaneously, demonstrated as a 3-dimensional temperature distribution and stored. In well-controlled, systematic experiments a significant correlation has been observed between standard temperature and temperature using this system at various measuring points. Conclusion: This thermometry system is a real-time measurement system, which can demonstrate 3-dimensional heat distribution in experimental phantom and human body and can be used for diagnosing abnormal clinical conditions. In addition, this system reduces the nursing staff work load, providing them more time for long term care to patients.

  • PDF

Liver Size Measurement Method by Ultrasonography and Reference Range based on Normal Adult Physique Index (초음파검사에 의한 간 크기 측정방법 및 정상 성인의 체격지수별 참조범위)

  • Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.13-24
    • /
    • 2018
  • Liver size is an important component in the diagnosis and follow-up of diffuse liver disease when testing for liver disease using ultrasonography. However, difficulties lies in determining the presence of hepatomegaly and liver atrophy because the method used for measuring liver size differs from one examiner to another and there is no relevant standard based on body build. The present study aims to propose a more objective method for liver size measurement and a reference range based on body build. A total of 260 normal adults (130 males, 130 females) participated in the study. Ultrasonography was performed in all participants to measure the size of the right lobe, left lobe, quadrate lobe, and caudate lobe of liver. Based on Physique Index(PI), a value derived from multiplying weight(kg) by height($m^2$), size of physique was divided into three groups including Group I with PI<150, Group II with $150{\leq}PI{\leq}250$, and Group III with PI>250. Thus, mean liver size by PI and a reference range with 95% reliability were suggested. The superoinferior diameter of right lobe was $12.34{\pm}1.18cm$ in males and $11.07{\pm}0.93cm$ in females, and its reference range was 10.64~11.0cm for Group I, 11.78~12.12cm for Group II, and 13.02~13.84cm for Group III. The anteroposterior diameter(T) of left lobe was $5.93{\pm}1.09cm$ in males and $5.18{\pm}0.99cm$ in females, and its reference range was 4.77~5.17cm for Group I, 5.49~5.79cm for Group II, and 6.68~7.44cm for Group III. The transverse diameter was $3.51{\pm}0.60cm$ in male participants and $3.42{\pm}0.49cm$ in female participants and its reference range was 3.29~3.51cm for Group I, 3.36~3.55cm for Group II, and 3.52~4.0cm for Group III. The caudate lobe index was $11.65{\pm}2.88cm^2$ in males and $9.62{\pm}2.18cm^2$ in females and its reference range was $8.83{\sim}9.75cm^2$ for Group I, $10.62{\sim}11.47cm^2$ for Group II, and $11.89{\sim}14.26cm^2$ for Group III. As a basic measurement method of liver size, the present study suggests measuring the superoinferior diameter for right liver lobe, the anteroposterior diameter for left liver lobe, the transverse diameter for quadrate lobe, and the caudate lobe index for caudate lobe. It is expected that this method along with its relevant reference range can be used as useful indicators in determining hepatomegaly and liver atrophy upon the diagnosis and follow-up testing of diffuse liver disease.

Prostate Volume Measurement by Transrectal Ultrasonography in the Healthy Korean Men in Thirties (건강한 30대 한국인 남성에서 경직장초음파를 이용한 전립선 용적 측정)

  • Kim, Yon-Min;Jeong, Jeong-Yun;Han, Dong-Kyoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.338-345
    • /
    • 2012
  • Benign prostatic hyperplasia (BPH) is increasing in Korea owing to the westernized eating habits and changes in living environment. However, very few studies have been made to determine the standard value of the prostate volume as a diagnostic reference. Also, most of the previous studies have been focusing on the elder population over 40 years old. This study retrospectively analyzes the results of prostate volume measured by transrectal ultrasonography in the healthy Korean men in their 30's who visited our institution's center for health promotion for routine checkups. The mean age of the total of 157 men enrolled was $34.6{\pm}2.9$ years, and the mean prostate volume was $19.4{\pm}4.0ml$. Prostate volume of these men was correlates proportionally to their age, prostate specific antigen, body mass index, body surface area, and abdominal girth. Among these, the strongest correlation is between the prostate volume and the abdominal girth (r=0.317, p<0.001).

Design of Multi-Meander Microstrip Patch Antenna for Metallic Object in u-City (u-City용 금속 부착을 위한 다중 미앤더형 마이크로스트립 패치 안테나 설계)

  • Choi, Yong-Seok;Seong, Hyeon-Kyeong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • In this paper, we present a design of meander type microstrip patch antenna which has the best quality in RFID approved international standard of 910MHz broadband, usable in metal environment. In order to be fit into the commercial tag chip on the antenna, a square shaped feeder is installed on the main body as well as in the main body. In addition, a multi meander type patching element was designed in order to reduce the main body effectively. Three antennae, Cases 1, 2 and 3, were designed and compared in the areas of broad band width, effectiveness or recognition distance according to their sizes and number of folds. The measurement result of Case 3 was determined to be the best. It was confirmed that mostly the efficiency and characteristic gain change due to antenna size and number of folds in meander type influenced the antenna recognition distance.

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

Comparative study of the Korean Regulations, Standards and Guidelines for the Human Vibration with Other Countries

  • Kim, Day Sung;Lee, Dong-Kyung;Kim, Kyoo Sang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.321-331
    • /
    • 2013
  • Objective: The aim of this study is to review the literatures on the regulation, standard and guideline for the human vibration in Korea and other countries. Background: This review can be used to prevent various diseases caused by the human vibration as a basis for the development of the policy. Results: In Korea, the general employers' duties related to human vibration are set forth the Health Measures(Article 24) in the Occupational Safety and Health Act. And then an employer shall take measures to protect the health of the workers concerned by improving other working conditions relating to working hours for the vibration prevention measures referred to in Article 24 of the Act. The European Union adopted a Directive in 2002 on minimum requirements for the health and safety of workers exposed to vibration. New Regulations on Vibration at Work will be introduced in Great Britain on 2005 to implement the Directive. In the U.S., both ANSI and ACGIH adopted the ISO standard for measurement and suggested exposure action and limit values. In Japan, the Ministry of Labor decided that the vibration syndrome among operators of rock drills and riveters etc. could be included in an occupational disease(1947). In addition, ISO standard was based on proposals and draft documents of many countries such as U.K, Japan and European, etc. Conclusion: In Korea, Occupational Safety and Health Act prevent vibration to health, but do not include exposure limits. It is therefore important to consider the new duties regarding to vibration risks added to the general duties.

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

A Study of the Implementation Guidance to ISO 9001:2000 in the Computer Software Industry

  • Lee, Byung-Yong;Jung, Soo-Il
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.53
    • /
    • pp.99-109
    • /
    • 1999
  • The International Organization for Standardization(ISO) is a worldwide federation of national standards bodies. Through ISO Technical Committees(TC), various International Standards are being carried out. Each member body interested in a subject for which a TC has been established has the right to be represented on that committee. ISO collaborates closely with the International Electro-technical Commission(IEC) on all matters of electro-technical standardization. ISO established the ISO 9000 Family standard in 1987, and International Standard ISO 9000-3 was worked by ISO/TC 176, Quality management and quality assurance, Subcommittee 2(SC 2), Quality systems, in accordance with the ISO/IEC Directives, Part 3: 1997 Rules for the structure and drafting of International Standards, Many organizations have applied the ISO 9000-3 for their quality system standard in the software sector. That means that ISO 9000-3: 1991 and ISO 9000-3: 1997 have been used successfully by the software industry as the internationally accepted interpretation of ISO 9001 for the development and maintenance of computer software. Additionally ISO 9000-3: 1997 involved how the software life cycle processes defined in ISO/IEC 12207: 1995, Information Technology - Software Life Cycle Processes related to the requirements of ISO 9001:1994. After having performed full reviews of the WD3, CD1, CD2 and DIS drafts of the future ISO 9001:2000, this document will partly replace the part of ISO 9000-3: 1997 for measurement analysis and improvement of quality management system in computer software industry, as an interpretation for organizations and certification bodies, which will be withdrawn when ISO 9001:1994 is replaced by ISO 9001:2000,.

  • PDF

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

The 3D Character Modeling for Golf Swing Motion Analysis by Economical Verification of Body Information (인체정보 DB의 경제적인 조합을 통한 골프 스윙 동작 분석용 3D 캐릭터 모델링)

  • 곽현민;채균식;박찬종;이상태
    • Science of Emotion and Sensibility
    • /
    • v.6 no.2
    • /
    • pp.59-64
    • /
    • 2003
  • The national standard anthropometry of Korea is conducted every 5∼6 year term after its first research was started in 1979, The fourth research was conducted in 1997. The result of the national standard anthropometry has been reflected in manufactured goods design of allied industries such as clothing, shoes and furniture. In this paper, we measured anthropometry data for every bodily figurative classification after dividing users according to gender, age and bodily figure using the result of the national standard anthropometry. We constructed 3D character through the process of analyzing interrelation of measured anthropomeoy and measuring representative category. In the process for organization , we measured anthropometry which can effectively express sports action of golf, tennis etc. We made it by presenting measurement which is able to form each type of 3D character after the category was decided. Quantitative and objective valuation for posture and action became possible by developing visible information offer and posture action analysis protocol in theoretical approach for analysis of posture and action in sports.

  • PDF