• 제목/요약/키워드: the signal analysis

검색결과 7,909건 처리시간 0.034초

Hybrid Linear Analysis Based on the Net Analyte Signal in Spectral Response with Orthogonal Signal Correction

  • Park, Kwang-Su;Jun, Chi-Hyuck
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.1-8
    • /
    • 2000
  • Using the net analyte signal, hybrid linear analysis was proposed to predict chemical concentration. In this paper, we select a sample from training set and apply orthogonal signal correction to obtain an improved pseudo unit spectrum for hybrid least analysis. using the mean spectrum of a calibration training set, we first show the calibration by hybrid least analysis is effective to the prediction of not only chemical concentrations but also physical property variables. Then, a pseudo unit spectrum from a training set is also tested with and without orthogonal signal correction. We use two data sets, one including five chemical concentrations and the other including ten physical property variables, to compare the performance of partial least squares and modified hybrid least analysis calibration methods. The results show that the hybrid least analysis with a selected training spectrum instead of well-measured pure spectrum still gives good performances, which is a little better than partial least squares.

독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출 (Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation)

  • 전학재;김정도;임승주
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

웨이브렛 변환을 이용한 비정상 신호의 순간 주파수 결정 (Non-stationary signal analysis by Continuous Wavelets Transform)

  • 조익현;이인수;윤동한
    • 한국정보전자통신기술학회논문지
    • /
    • 제2권2호
    • /
    • pp.29-36
    • /
    • 2009
  • 비선형적인 위상 변화를 지닌 비정상(non-stationary)신호는 레이더(Radar), 통신(telecommunication), 생체공학, 지질탐사, 음향 등 여러 분야에서 쉽게 접하는 신호이다. 비정상신호는 일반적으로 시간에 따라 신호의 물리적 특성이 변화하는 신호를 의미하며, 순간 주파수는 신호의 특정시간에 해당하는 신호의 주파수를 의미한다. 이 논문에서는 순간 주파수를 결정하기 위한 연속 웨이브렛 변환의 적용에 대하여 논하였다.

  • PDF

CFM에서 하강 에지 정렬과 파라미터 에러 평가에 의한 크림프 시그널 분석 성능 향상 (Improving Performance of Crimp Signal Analysis by Falling Edge Alignment and Parameter Error Estimation in CFM)

  • ;강태삼;한충권;박정근
    • 제어로봇시스템학회논문지
    • /
    • 제22권9호
    • /
    • pp.686-692
    • /
    • 2016
  • A Crimp Force Monitor (CFM) is equipment for detecting crimp errors by analyzing crimp signals obtained from force and strain sensors. The analysis is commonly performed by aligning a measured crimp signal with a reference signal and comparing their difference. Current analysis methods often suffer from wrong alignments that result in false negative detections. This paper presents a new crimp signal analysis method in CFM. First, a falling edge alignment is proposed that matches falling edges of the measured and the reference signals by minimizing the absolute difference summation. Second, a signal parameter error is introduced to evaluate the crimp quality difference between the measured signal and the reference. For calculating the signal parameter error, part of a signal is identified and divided into several regions to maximize the signal parameter errors. Experiments showed that the proposed method can improve the signal alignment and accurately detect bad crimps especially with the strain sensor.

휴대형 모바일 와이맥스 기지국 신호분석 시스템 설계 (Design of Portable Signal Analysis System for Mobile WiMax Base Station)

  • 최종호
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권1호
    • /
    • pp.39-45
    • /
    • 2011
  • 본 논문에서는 공통의 플랫폼을 기반으로 하는 모바일 와이맥스 기지국 운용용 휴대형 신호분석 시스템의 설계방법을 제안하고, 이를 하드웨어 모듈로 구현하였다. 새롭게 제안한 신호분석 방법은 RF 신호의 IF 신호로의 하향 변환 및 이득제어를 수행하는 광대역 RF 모듈과 계측 기능을 수행하는 DSP 기반 디지털 신호분석 모듈로 구현하는 것이다. 타 고정 대형 시스템과의 비교를 통해 수행한 신호분석 알고리즘의 성능을 검증한 결과, 분해능의 차이는 없음을 확인하였다.

DGPS 기준국 신호분석 소프트웨어 (Signal Analysis Software for DGPS Station)

  • 황호연
    • 한국항공운항학회지
    • /
    • 제15권2호
    • /
    • pp.1-8
    • /
    • 2007
  • In this research, algorithm and software for the medium frequency signal analysis of DGPS(Differential Global Positioning System) station were developed. Based on new MF(Medium Frequency) algorithm, the software of NDGPS(National DGPS) signal analysis was developed for coverage analysis. Predicted MF propagation data from this software was compared to the measurement data for the verification of a developed MF algorithm. GIS(Geographic Information System) techniques including digital map with elevation data were used because MF propagation is closely related to ground conductivity, mountains, building intensity.

  • PDF

회전체의 진동신호분석을 위한 신호보간의 오차분석 (Comparison Error of Signal Interpolation Methods for Vibration Signal Analysis of Revolution Machine)

  • 박준용;박종연
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권12호
    • /
    • pp.820-826
    • /
    • 2004
  • In this paper, studied error of various signal interpolation methods in vibration signal analysis with digital order tracking. Because, interpolation errors are related with sampling rate and amount of calculation. Appled Signal interpolation methods are Lagrange, Newton and Cubic-spline. This paper proposed more proper interpolation method. Also, we suggest guideline for adaptive application of signal interpolation methods with Calculated results.

중추성 작용 약물의 뇌파 효과의 정량화를 위한 스펙트럼 분석에 필요한 기본적 조건의 검토 (Basic ]Requirements for Spectrum Analysis of Electroencephalographic Effects of Central Acting Drugs)

  • 임선희;권지숙;김기민;박상진;정성훈;이만기
    • Biomolecules & Therapeutics
    • /
    • 제8권1호
    • /
    • pp.63-72
    • /
    • 2000
  • We intended to show some basic requirements for spectrum analysis of electroencephalogram (EEG) by visualizing the differences of the results according to different values of some parameters for analysis. Spectrum analysis is the most popular technique applied for the quantitative analysis of the electroen- cephalographic signals. Each step from signal acquisition through spectrum analysis to presentation of parameters was examined with providing some different values of parameters. The steps are:(1) signal acquisition; (2) spectrum analysis; (3) parameter extractions; and (4) presentation of results. In the step of signal acquisition, filtering and amplification of signal should be considered and sampling rate for analog-to-digital conversion is two-time faster than highest frequency component of signal. For the spectrum analysis, the length of signal or epoch size transformed to a function on frequency domain by courier transform is important. Win dowing method applied for the pre-processing before the analysis should be considered for reducing leakage problem. In the step of parameter extraction, data reduction has to be considered so that statistical comparison can be used in appropriate number of parameters. Generally, the log of power of all bands is derived from the spectrum. For good visualization and quantitative evaluation of time course of the parameters are presented in chronospectrogram.

  • PDF

감쇠비를 고려한 가속도 신호의 프랙탈 해석 (Fractal analysis of acceleration signal considering damping)

  • 윤문철
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.157-162
    • /
    • 2013
  • To analyze the dynamic acceleration characteristics, it is necessary to identify the acceleration model using some methods that can represent the dynamic properties well. In this sense, fractal methods were used for the verification of characteristics of an acceleration signal. To estimate and analyze the geometry of acceleration signal, a fractal interpolation and its analysis was introduced in this paper. The chaotic nature of acceleration signal was considered in fractal modeling. In this study the fractal signal modeling has brought a focus within the scope of the fractal interpolation and fractal dimension. And a new idea of fractal dimension has been introduced and discussed considering the damping ratio and amplitude for its dynamic properties of the signal. The fractal dimension of acceleration with respect to the scaling factor using fixed data points of 1000 points was calculated and discussed. The acceleration behaviors of this results show some different characteristics. And this fractal analysis can be applied to other signal analysis of several machining such as pendulum type grinding and milling which has many dynamic properties in the signal.

Wavelet Transform을 이용한 Heart Sound Analysis (Analysis of Heart Sound Using the Wavelet Transform)

  • 위지영;김중규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 제13회 신호처리 합동 학술대회 논문집
    • /
    • pp.959-962
    • /
    • 2000
  • A heart sound algorithm, which separates the heart sound signal into four parts; the first heart sound, the systolic period, the second heart sound, and the diastolic period has been developed. The algorithm uses discrete intensity envelopes of approximations of the wavelet transform analysis method to the phonocard-iogram(PCG)signal. Heart sound a highly nonstation-ary signal, so in the analysis of heart sound, it is important to study the frequency and time information. Further more, Wavelet Transform provides more features and characteristics of the PCG signal that will help physician to obtain qualitative and quantitative measurements of the heart sound.

  • PDF