• 제목/요약/키워드: the rate of concordance

검색결과 146건 처리시간 0.023초

단축형 사상체질 진단설문지(KS-15)의 일본인 적용 가능성 확인을 위한 예비연구 (Applying KS-15 (Korea Sasang Constitutional Diagnostic Questionnaire) to the Japanese : a Pilot Study)

  • 박기현;백영화;이시우
    • 동의생리병리학회지
    • /
    • 제32권1호
    • /
    • pp.70-74
    • /
    • 2018
  • The purpose of this study was to evaluate the possibility of applying Korea Sasang Constitutional Diagnostic Questionnaire(KS-15) for the Japanese. We analyzed the results of 50 Japanese participants who visited the local university hospital from October 2010 to July 2011 and their Sasang constitutions were diagnosed by a Sasang Constitutional specialist. Two items(14.3%) of total 14 items, except for BMI showed 0.4 or below in Kappa, 8 items(57.1%) were ranged from 0.4 to 0.6 and 4 items(28.6%) marked 0.6 or over. The concordance rate between the results of KS-15 and those of expert was 60% in total Japanese participants.(61.9% in Taeeumin, 60% in Soeumin, and 57.9% in Soyangin). The KS-15 could be suitable for supporting experts to diagnose the Sasang constitution of the Japanese. In order to increase usefulness, when subsequently applying KS-15 to foreign site, KS-15 should be properly adjusted in sociocultural characteristic.

알레르기 비염의 한의학적 분류를 위한 진단 평가지와 한의사 변증의 일치도 평가 (Assessment of Concordance Rate in Pattern Analysis between Pattern Diagnosis of KiFDA on Allergic Rhinitis in 2008 and Doctor of Korean Medicine)

  • 이규진;김희택;장보형;최인화;고성규
    • 한방안이비인후피부과학회지
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2014
  • Objective : This study aimed to assessment for concordance rate in pattern analysis between pattern diagnosis of KiFDA on allergic rhinitis in 2008 and doctor of Korean medicine. Methods : Data were obtained from 35 patients with allergic rhinitis(AR). They were asked to perform the questionnaires and had been interviewed by specialist of Korean Medicine. For correlation analysis, we used Cohen's Kappa. Results : The pattern diagnosis was done only 15 patients(42.9%). Correlation between pattern diagnosis of questionnaires and specialist showed 0.2105 in Kappa and 0.1993 in weighed Kappa. Conclusions : The result may provide the basis of modification in Pattern Diagnosis of KiFDA on allergic rhinitis in 2008.

편마비 환자의 상지 재활 기기 운용을 위한 관절 각 추정 기법에 관한 연구 II (Study on The Estimation Method of the Joint for the Operation of the Upper Limb Rehabilitation Equipment for Hemiplegic Patients II)

  • 송기선;엄수홍;이응혁
    • 재활복지공학회논문지
    • /
    • 제8권4호
    • /
    • pp.313-318
    • /
    • 2014
  • 본 논문은 편마비환자들의 상지재활 기기 운용방법으로 건측에서 관성측정장치를 기반으로 한 관절각 추정 기법과 착용 과정에서 발생하는 측정축 뒤틀림을 보정하는 기법을 제안한다. 제안하는 기법을 검증하기 위해 실험자 왼팔의 상완과 전완에 관성측정장치를 부착하였으며, 임의의 자세를 촬영하여 검출한 실제 관절 각과 관절각 추정한 각과 비교하여 검증 하였다. 그리고 측정축 뒤틀림을 보정하는 기법을 적용 전/후를 비교하여 검증하였다. 실험 결과 측정축 뒤틀림 보정을 적용전은 관절각 일치율이 89.16%로 저조한 일치율을 보였으나, 측정축 뒤틀림을 보정한 후에 관절각 일치율은 93.28%의 일치율로 4.12% 개선되었음을 확인 하였다.

  • PDF

공복혈당과 당화혈색소를 적용한 당뇨병 이상소견자의 분포 및 특성 - 당뇨병 기진단자를 제외한 성인을 대상으로 (The Distribution and Characteristics of Abnormal Findings Regarding Fasting Plasma Glucose and HbA1c - Based on Adults Except for Known Diabetes)

  • 권세영;나영악
    • 대한임상검사과학회지
    • /
    • 제49권3호
    • /
    • pp.239-247
    • /
    • 2017
  • 현재 임상에서 적용되고 있는 대표적인 당뇨 진단 기준에는 표준검사법인 경구당부하검사, 공복혈당, 당화혈색소가 있다. 그러나, 검사별로 판정이 일치하지 않는 경우가 많다. 본 연구에서는 선별검사에서 행해지는 공복혈당과 당화혈색소를 이용하여 당뇨병 판정의 일치도를 구해보고, 유형별로 그 특성을 살펴 보았다. 국민건강영양조사 데이터(2015) 중 측정치 누락자, 당뇨병 기진단자, 공복 8시간 미만인 자를 제외한 20세 이상 대상자 4,502명(남성 1,956명, 여성 2,546명)의 자료를 이용하였다. 공복혈당과 당화혈색소 농도를 당뇨병 진단기준의 세 범주(정상, 당뇨병 전단계, 당뇨병)로 나누어 살펴본 남성 대상자의 분포에서 공복혈당 100 mg/dL~125 mg/dL이면서 HbA1c ${\geq}6.5%$인 대상자는 664명 중 23명, 새롭게 진단된 당뇨군 86명 중 39명은 공복혈당 ${\geq}126mg/dL$ 이면서 HbA1c < 6.5%로 나타났다. 판정의 일치율은 비당뇨군 80.3% 당뇨군 54.7%, 당뇨병 전단계에서 44.9%로 가장 낮았다. 코헨의 kappa 값은 남성의 경우 0.322, 여성의 경우 0.362로 일치도가 낮게 나타났고, 두 범주(비당뇨병, 당뇨병)로 나누었을 때 남성의 경우 0.582, 여성의 경우 0.637로 나타나 더 높은 일치도를 보였다. 공복혈당 <126 mg/dL이며 HbA1c < 6.5%인 군에서 연령도 낮고 대부분의 혈액 측정치도 낮게 나타났으며, 공복혈당 ${\geq}126mg/dL$ 이면서 HbA1c ${\geq}6.5%$인 군에서 남성의 경우 허리둘레, 혈압, 총 콜레스테롤, 중성지방의 수치가 높고 여성의 경우 ALT, hsCRP가 높게 나타났다. 남녀 모두 공복혈당 ${\geq}126mg/dL$인 군에서 인슐린저항성 지표인 HOMA IR값이 유의하게 높았고, <126 mg/dL인 군에서 인슐린감수성 지표인 QUICKI 값이 유의하게 높았다. 당뇨병 판정의 낮은 일치도 및 진단검사의 특성을 고려하여 관련검사의 병행 해석이 필요하다.

Evaluation of HER-2/neu Overexpression in Gastric Carcinoma using a Tissue Microarray

  • Rakhshani, Nasser;Kalantari, Elham;Bakhti, Hadi;Sohrabi, Masoud Reza;Mehrazma, Mitra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7597-7602
    • /
    • 2014
  • Background: Amplification and overexpression of human epidermal growth factor receptor 2 (HER2/neu) oncogene has considerable prognostic value in breast and gastric cancers. This study aimed to evaluate the frequency, overexpression pattern, clinical significance, and concordance between the results for protein expression and gene amplification of HER-2/neu in gastric and gastro-esophageal junction carcinomas. Materials and Methods: In this study, 101 gastric tissue samples which were included in tissue microarray were immunohistochemically examined for overexpression of HER2/neu. Chromogenic in situ hybridization (CISH) was used for HER-2/neu amplification. The correlation of HER2/neu amplification with clinicopathological parameters was also assessed. In addition, concordance between CISH and IHC was detected. Results: This study demonstrated a significant difference in the overexpression of HER2/neu in gastric tumors. The overexpression of HER2/neu was significantly higher in intestinal type, poorly differentiated grade, large size ($5cm{\leq}$) and positive nodal involvement tumors (p-value=0.041, 0.015, 0.038 and 0.071, respectively). Also, amplification of HER2/neu according to CISH test, had a significant positive correlation with tumor size and tumor type (p-value=0.018 and 0.058, respectively).Concordance between CISH and IHC was 76.9% in 101 evaluable samples. Conclusions: IHC/CISH differences were attributed to basolateral membranous immunoreactivity of glandular cells resulting in incomplete membranous reactivity and/or a higher rate of tumor heterogeneity in gastric cancers compared to breast cancers. Therefore, this can be a potential marker for targeted therapy of malignant gastric tumors.

Implications for the Predictivity of Cell-Based Developmental Toxicity Assays Developed Two Decades Apart

  • Kawamura, Satoshi;Horie, Nobuyuki;Okahashi, Noriko;Higuchi, Hashihiro
    • Toxicological Research
    • /
    • 제35권4호
    • /
    • pp.343-351
    • /
    • 2019
  • Many in vitro developmental toxicity assays have been proposed over several decades. Since the late 1980s, we have made intermittent attempts to introduce in vitro assays as screening tests for developmental toxicity of inhouse candidate products. Two cell-based assays which were developed two decades apart were intensively studied. One was an assay of inhibitory effects on mouse ascites tumor cell attachment to a concanavalin A-coated plastic sheet surface (MOT assay), which we studied in the early days of assay development. The other was an assay of inhibitory effects on the differentiation of mouse embryonic stem cell to beating heart cells (EST assay), which we assessed more recently. We evaluated the suitability of the assays for screening in-house candidates. The concordance rates with in vivo developmental toxicity were at the 60% level. The EST assay classified chemicals that inhibited cell proliferation as embryo-toxic. Both assays had a significant false positive rate. The assays were generally considered unsuitable for screening the developmental toxicity of our candidate compounds. Recent test systems adopt advanced technologies. Despite such evolution of materials and methods, the concordance rates of the EST and MOT systems were similar. This may suggest that the fundamental predictivity of in vitro developmental toxicity assays has remained basically unchanged for decades. To improve their predictivity, in vitro developmental toxicity assays should be strictly based on elucidated pathogenetic mechanisms of developmental toxicity.

SAR 위성 영상을 이용한 수계탐지의 최적 머신러닝 밴드 조합 연구 (Selection of Optimal Band Combination for Machine Learning-based Water Body Extraction using SAR Satellite Images)

  • 전현균;김덕진;김준우;수레시 크리쉬난;김재언;김택인;정승환
    • 한국지리정보학회지
    • /
    • 제23권3호
    • /
    • pp.120-131
    • /
    • 2020
  • 인공위성 영상을 기반으로 한 기계판독(machine interpretation) 원격탐사 수계 탐지는 효율적인 수자원 관리, 가뭄 탐지, 홍수 모니터링 등에 큰 도움이 된다. 따라서 본 연구에서는 머신러닝을 기반으로 한 SAR 위성 영상 기반 수계 탐지를 시행하였다. 그러나 SAR 위성 영상만을 사용하였을 경우 음영 효과 또는 도로 등의 수계와 비슷한 산란특성을 가지는 물체로 인하여 비수계가 수계로 오탐지 될 수 있다. 이러한 오탐지를 줄이기 위하여 목포 지역을 촬영한 Cosmo-SkyMed SAR 위성 영상에 모폴로지(Morphology)의 open 연산을 거친 밴드와 DEM(수치표고모델) 밴드, Curvature(곡률) 밴드를 조합하여 중첩한 8가지 경우에 대하여 의미 분할 기법 머신러닝 모델을 학습시켰다. 8가지 머신러닝 모델에 대한 최종 테스트 결과인 Global Accuracy를 구하였으며, 목포 지역의 토지피복지도와의 일치율 역시 비교하였다. 그 결과 SAR 위성 영상과 모폴로지 open 필터를 적용한 밴드, DEM 밴드, Curvature 밴드를 모두 사용한 경우가 Global Accuracy뿐만 아니라 토지피복지도와의 일치율 역시 가장 높음을 확인할 수 있었다. 이때 Global Accuracy는 95.07%였으며, 토지피복지도와의 일치율은 89.93%로 나타났다.

사상체질 진단 도구(SCAT)와 전문가에 의해 판정된 사상체질별 신체적 특성 (Physical characteristics according to Sasang constitution typology determined by Sasang Constitution Analysis Tool(SCAT) and a specialist)

  • 김순미
    • 한국융합학회논문지
    • /
    • 제11권12호
    • /
    • pp.363-371
    • /
    • 2020
  • 사상체질별 체형 특성을 살펴보기 위하여 대상자들의 체질을 사상 체질 진단 도구인 SCAT와 민간인 전문가에 의해 판정하고 결과가 일치하는 대상자의 8개 부위 신체둘레와 이들의 비율을 분석하였다. SCAT와 전문가의 체질 판정 일치율은 남녀 각각 33.0 %, 41.5 %이었으며, 소양인의 일치 비율이 가장 낮았다. 사상체질에 따른 신체둘레 비율 특성은 남성보다 여성에서 더 뚜렷하게 나타났다. 여성의 이마/목, 가슴/장골, 늑골/장골, 늑골/곡골 둘레 비율은 SCAT, 전문가 모두에서 동일한 결과를 나타내었다. 체질 판정에 있어서 둘레를 측정하는 것 보다 특정 둘레 사이의 비율을 측정하는 것이 더 의미 있는 기준이 될 수 있음을 확인하였다.

Clinicopathological Significance and Diagnostic Accuracy of c-MET Expression by Immunohistochemistry in Gastric Cancer: A Meta-Analysis

  • Pyo, Jung-Soo;Kang, Guhyun;Cho, Hyunjin
    • Journal of Gastric Cancer
    • /
    • 제16권3호
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: The aim of the present study was to elucidate the clinicopathological significance and diagnostic accuracy of immunohistochemistry (IHC) for determining the mesenchymal epidermal transition (c-MET) expression in patients with gastric cancer (GC). Materials and Methods: The present meta-analysis investigated the correlation between c-MET expression as determined by IHC and the clinicopathological parameters in 8,395 GC patients from 37 studies that satisfied the eligibility criteria. In addition, a concordance analysis was performed between c-MET expression as determined by IHC and c-MET amplification, and the diagnostic test accuracy was reviewed. Results: The estimated rate of c-MET overexpression was 0.403 (95% confidence interval [CI], 0.327~0.484) and it was significantly correlated with male patients, poor differentiation, lymph node metastasis, higher TNM stage, and human epidermal growth factor receptor 2 (HER2) positivity in IHC analysis. There was a significant correlation between c-MET expression and worse overall survival rate (hazard ratio, 1.588; 95% CI, 1.266~1.992). The concordance rates between c-MET expression and c-MET amplification were 0.967 (95% CI, 0.916~0.987) and 0.270 (95% CI, 0.173~0.395) for cases with non-overexpressed and overexpressed c-MET, respectively. In the diagnostic test accuracy review, the pooled sensitivity and specificity were 0.56 (95% CI, 0.50~0.63) and 0.79 (95% CI, 0.77~0.81), respectively. Conclusions: The c-MET overexpression as determined by IHC was significantly correlated with aggressive tumor behavior and positive IHC status for HER2 in patients with GC. In addition, the c-MET expression status could be useful in the screening of c-MET amplification in patients with GC.

복합 생체신호를 이용한 능동형 스피닝 트레이닝 시스템 (Active Spinning Training System using Complex Physiological Signals)

  • 김철민;강경헌;김은석
    • 한국콘텐츠학회논문지
    • /
    • 제15권7호
    • /
    • pp.591-600
    • /
    • 2015
  • 최근 건강에 대한 관심이 높아짐에 따라 운동 프로그램을 스스로 학습하고 즐길 수 있는 능동형 피트니스 시스템에 대한 연구가 활발히 진행되고 있다. 본 논문에서는 운동 참여자의 생체신호에서 획득한 생체상태와 운동 정보를 이용하여 개인 수준에 맞는 스피닝 트레이닝 프로그램을 자기 주도 방식으로 학습 및 체험할 수 있게 하는 능동형 스피닝 트레이닝 시스템을 설계하고 구현하였다. 제안 시스템은 운동 참여자의 뇌파와 맥파 신호를 통해 생체 상태를 분석하고, 골격 동작을 실시간 인식하여 검출된 스피닝 동작 일치율과 운동량을 반영하여 운동 참여자에게 적합한 난이도의 스피닝 프로그램을 제공한다. 또한, 가상 스피닝 강사를 통해 올바른 동작을 제시하고 참여자의 동작 일치율에 따라서 난이도를 조절함으로써 운동 효과를 높일 수 있도록 하였다. 다양한 사용자들에 대한 실험을 통해 제안시스템이 비교적 짧은 시간에 유효한 운동 효과를 얻는데 도움이 됨을 확인할 수 있었다.