• Title/Summary/Keyword: the property (C)

Search Result 4,356, Processing Time 0.034 seconds

A Study of pH, Duty Cycle, Agitation on the Property of Co-deposited TiO2 and Thermal Stability in the Electrodeposited Ni-TiO2 Composite (pH, duty cycle, 교반, 첨가제가 Ni-TiO2 전기도금 복합체의 TiO2 공석특성과 열적안정성에 미치는 영향 연구)

  • Kim, Myong-Jin;Kim, Joung-Soo;Kim, Dong-Jin;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.3
    • /
    • pp.97-105
    • /
    • 2012
  • The effects of pH, types of applied current, agitation method and time, additive on the amount of co-deposited $TiO_2$ particles in the matrix were investigated. The deposition rates increased with increasing pH values, while the volume fraction of $TiO_2$ particles and the size of agglomerated $TiO_2$ particles in the composite decreased. The volume fraction of $TiO_2$ particles in the composite decreased when pulsed current of 50% duty cycle was used. And the size of agglomerated $TiO_2$ particles in the nickel matrix of pulsed current was smaller than that of DC current specimen. The volume fraction of $TiO_2$ particles in the matrix decreased with longer time by air agitation, but in case of using magnetic bar, volume fraction in the same range of time was relatively constant. The volume fraction of the electrodeposited Ni-$TiO_2$ composite in the solution containing 0.01 M Dimethylamine borane (DMAB) increased slightly with increasing agitation time regardless of agitation methods. Thermal stability of the electrodeposited Ni-$TiO_2$ composite increased with lower pH at the temperature range of $200{\sim}800^{\circ}C$, and the results showed that the amount of co-deposited $TiO_2$ relies more on the deposition rate than zetapotential of $TiO_2$ particles.

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

Enhanced Transdermal Delivery of Procaine Hydrochloride by lontophoresis -Comparison of Synergic Effect of High Voltage Current and Ultrasound- (이온도입에 의한 염산프로카인의 경피전달 증대 -고전압전류 및 초음파 병행의 상승효과 비교-)

  • Lee, Jong-Sook;Kim, Kyoung-Won;Lee, Jae-Hyoung;Choi, Yeong-Wook;Lee, Jae-Hwi
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.185-192
    • /
    • 2006
  • The purpose of this study was to determine the effects of iontophoresis on transdermal delivery of procaine hydrochloride in healthy volunteers, as well as to the synergic effect of high voltage current or ultrasound on the efficacy of transdermal delivery of iontophoresis. Forty healthy volunteers were randomly assigned to four groups topical application group (TA), iontophoresis group (IT), pre-treatment of high voltage current stimulation with iontophoresis (HVS + IT), and pre-treatment of ultrasound application with iontophoresis (US + IT). All subjects received procaine iontophoresis on the forearm using direct current with 4 mA f3r 15 minutes. All subject was measured the duration of local anesthesia, pressure pain threshold, pain perception threshold using rectangular wave at 0.2 ms, 1 ms, 50 ms of rectangular current stimulation after procaine iontophoresis. For comparisons of the sensory characteristics and efficacy of iontophoresis between the groups, an one-way ANOVA and Kruskal-Wallis were used. The significant difference the duration of local anesthesia were found between the groups (p<0.001). The local anesthetic duration of IT, HVS+IT were significantly longer than TA. Meanwhile, the local anesthetic duration of US+IT was significantly longer than HVS+IT, IT and TA group (p<0.05). Also, the pressure pain threshold, pain perception threshold at 0.2 ms, 1 ms, 50 ms were significant difference between the groups (p<0.001). All sensory characteristics including pressure pain threshold, pain perception threshold of IT, HVS+IT was significantly increased than TA, whereas, US+1T was significantly increased HVS+1T, IT and TA (p<0.05). This study showed that the procaine iontophoresis have increase the duration of local anesthesia concomitantly pressure pain threshold and pain perception threshold of sensory nerve fibers such as $A-{\beta}$, $A-{\delta}$ and C fiber. This findings suggest that the iontophoresis enhanced the transdermal delivery of drug ions in vivo. The combination of ultrasound application and iontophoresis synergized the transdermal delivery of drug ions. It is suggests that an electric field, mechanical and heating property of ultrasound may contribute to synergic effect due to temporary changes of structure in the stratum corneum.

Improvement in $AI_2O_3$ dielectric behavior by using ozone as an oxidant for the atomic layer deposition technique (ALD법으로 제조된 $AI_2O_3$막의 유전적 특성)

  • 김재범;권덕렬;오기영;이종무
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.3
    • /
    • pp.183-188
    • /
    • 2002
  • In the present study AI$(CH_3)_3)$films were deposited by the ALD technique using trimethylaluminum(TMA) and ozone to improve the quality of the AI$(CH_3)_3)$ films, since the $OH^-$ radicals existing in the AI$(CH_3)_3)$ films deposited using TMA and $H_2O$ degrade the physical and the dielectric properties of the AI$(CH_3)_3)$ film. The XPS analysis results indicate that the $OH^-$ radical concentration in the AI$(CH_3)_3)$film deposited using $O_3$is lower than that using $H_2O$. The etch rate of the AI$(CH_3)_3)$film deposited using $O_3$is also lower than that using $H_2O$, suggesting that the chemical inertness of the former is better than the latter. The MIS capacitor fabricated with the TiN conductor and the $Al_2$O$_3$dielectrics formed using $O_3$offers lower leakage current, better insulating property and smaller flat band voltage shift $({\Delta}V_{FB})$.

ASIC Design of Lifting Processor for Motion JPEG2000 (Motion JPEG2000을 위한 리프팅 프로세서의 ASIC 설계)

  • Seo Young-Ho;Kim Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.5C
    • /
    • pp.344-354
    • /
    • 2005
  • In this paper, we proposed a new lifting architecture for JPEG2000 and implemented to ASIC. We proposed a new cell to execute unit calculation of lifting using the property of lifting which is the repetitious arithmetic with same structure, and then recomposed the whole lifting by expanding it. After the operational sequence of lifting arithmetic was analyzed in detail and the causality was imposed for implementation to hardware, the unit cell was optimized. A new lifting kernel was organized by expanding simply the unit cell, and a lifting processor was implemented for Motion JPEG2000 using it. The implemented lifting kernel can accommodate the tile size of $1024{\times}1024$, and support both lossy compression using the (9,7) filter and lossless compression using (5,3) filter. Also, it has the same output rate as input rate, and can continuously output the wavelet coefficients of 4 types(LL, LH, HL, HH) at the same time. The implemented lifting processor completed a course of ASIC using $0.35{\mu}m$ CMOS library of SAMSUNG. It occupied about 90,000 gates, and stably operated in about 150MHz though difference from the used macro cell for the multiplier. Finally, the improved operated in about 150MHz though difference from the used macro cell for the multiplier. Finally, the performance can be identified in comparison with the previous researches and commercial IPs.

ASIC Design of Lifting Processor for Motion JPEG2000 (Motion JPEG2000을 위한 리프팅 프로세서의 ASIC 설계)

  • Seo Young-Ho;Kim Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7C
    • /
    • pp.647-657
    • /
    • 2005
  • In this paper, we proposed a new lifting architecture for JPEG2000 and implemented to ASIC. We proposed a new cell to execute unit calculation of lifting using the property of lifting which is the repetitious arithmetic with same structure, and then recomposed the whole lifting by expanding it. After the operational sequence of lifting arithmetic was analyzed in detail and the causality was imposed for implementation to hardware, the unit cell was optimized. A new lifting kernel was organized by expanding simply the unit cell, and a lifting processor was implemented for Motion JPEG2000 using it. The implemented lifting kernel can accommodate the tile size of 1024$\times$1024, and support both lossy compression using the (9,7) filter and lossless compression using (5,3) filter. Also, it has the same output rate as input rate, and can continuously output the wavelet coefficients of 4 types(LL, LH, HL, HH) at the same time. The implemented lifting processor completed a course of ASIC using 0.35$\mu$m CMOS library of SAMSUNG. It occupied about 90,000 gates, and stably operated in about 150MHz though difference from the used macro cell for the multiplier. Finally, the improved operated in about 150MHz though difference from the used macro cell for the multiplier. Finally, the performance can be identified in comparison with the previous researches and commercial IPs.

The Influence of Plasma Surface Modification on Frictional Property of Natural Rubber Vulcanizates

  • Nah, C.;Kim, D.H.;Mathew, G.;Jeon, D.J.;Jurkowski, B.;Jurkowska, B.
    • Elastomers and Composites
    • /
    • v.39 no.1
    • /
    • pp.12-22
    • /
    • 2004
  • The plasma surface modification of natural rubber vulcanizate was carried out using chlorodifluoromethane in a radio-frequency (13.56 MHz) electrodeless bell type plasma reactor. The modification was qualitatively assessed by Fourier transform infrared spectroscopy. The frictional force of the plasma-treated surface was found to decrease with the time of plasma treatment. An increase in the surface polarity, as evidenced by the decrease in contact angle of a sessile drop of water and ethylene glycol on the natural rubber vulcanizate surface, was noted with the plasma modification. In the case of similar plasma treatment of glass surface, only a reduction in the polarity was observed. The use of geometric and harmonic mean methods was found to be useful to evaluate the London dispersive and specific components of surface free energy. Irrespective of the method used for evaluation, an increasing trend in the surface free energy was noted with increasing plasma treatment time. However, the harmonic mean method yielded comparatively higher values of surface free energy than the geometric mean method. The plasma surface modification was found to vary the frictional coefficient by influencing the interfacial, hysteresis and viscous components of friction in opposing dual manners.

Effect of PVP(polyvinylpyrrolidone) on the Ag Nano Ink Property for Reverse Offset Printing (PVP(polyvinylpyrrolidone)가 리버스 오프셋용 은 나노 잉크 물성에 미치는 영향)

  • Han, Hyun-Suk;Kwak, Sun-Woo;Kim, Bong-Min;Lee, Taik-Min;Kim, Sang-Ho;Kim, In-Young
    • Korean Journal of Materials Research
    • /
    • v.22 no.9
    • /
    • pp.476-481
    • /
    • 2012
  • Among the various roll-to-roll printing technologies such as gravure, gravure-offset, and reverse offset printing, reverse offset printing has the advantage of fine patterning, with less than 5 ${\mu}m$ line width. However, it involves complex processes, consisting of 1) the coating process, 2) the off process, 3) the patterning process, and 4) the set process of the ink. Each process demands various ink properties, including viscosity, surface tension, stickiness, and adhesion with substrate or clich$\acute{e}$; these properties are critical factors for the printing quality of fine patterning. In this study, Ag nano ink was developed for reverse offset printing and the effect of polyvinylpyrrolidone(PVP), used as a capping agent of Ag nano particles, on the printing quality was investigated. Ag nano particles with a diameter of ~60 nm were synthesized using the conventional polyol synthesis process. Ethanol and ethylene glycol monopropyl ether(EGPE) were used together as the main solvent in order to control the drying and absorption of the solvents during the printing process. The rheological behavior, especially ink adhesion and stickiness, was controlled with washing processes that have an effect on the offset process and that played a critical role in the fine patterning. The electrical and thermal behaviors were analyzed according to the content of PVP in the Ag ink. Finally, an Ag mesh pattern with a line width of 10 ${\mu}m$ was printed using reverse offset printing; this printing showed an electrical resistivity of 36 ${\mu}{\Omega}{\cdot}cm$ after sintering at $200^{\circ}C$.

Stress analysis for shotcrete lining on uneven tunnel perimeter (비평탄 굴착벽면의 숏크리트 라이닝에 대한 응력해석)

  • Lee, Seungdo;Moon, Hyun-Koo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.597-604
    • /
    • 2015
  • When a tunnel is constructed by drilling and blasting operation, the excavated perimeter becomes uneven due to overbreak at the drill holes so that the thickness of shotcrete tends to be irregular. In this case, the conventional stress analyses for tunnel lining of a uniform thickness cannot be readily applicable. In this study, the profile of tunnel perimeter assumed to be sinusoidal in order to simulate the uneven tunnel perimeter and to control the thickness of shotcrete by using the amplitude and wavelength. By adopting the sinusoidal function to a theoretical solution of stress analysis for uniform lining, the range of axial stress of irregular shotcrete can be estimated. The applicability of the approximate solution has been verified by performing a series of numerical analyses for various conditions. It is shown that the axial stress of shorcrete is highly dependent upon the irregularity of shotcrete, together with the ground property and initial stress conditions. It is also shown the shear stress is dependent upon the wavelength, and the stress condition becomes unfavorable where the thickness of shotcrete is relatively small. The approach developed in this study shows that the stress state where the thickness is relatively small is unfavourable, and it is necessary to take complementary measures when installing shotcrete after blasting.

Study of the Nondestructive Test Method for the Embrittlement Evaluation of Nuclear Reactor Vessel Material by $M{\ddot{o}}ssbauer$ Spectroscopy ($M{\ddot{o}}ssbauer$ 분광법에 의한 원자로 용기재료의 비파괴적 중성자 조사평가에 대한 연구)

  • Jung, M.M.;Jang, K.S.;Yoo, K.B.;Kim, G.M.;Yoon, I.S;Hong, C.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.183-190
    • /
    • 2000
  • The purpose of this study is to evaluate the magnetic property change of the nuclear reactor vessel steel irradiated by fast neutrons using $M{\ddot{o}}ssbauer$ spectroscopy, and the effects of the defects produced by neutron irradiation on the changes using X-ray diffraction. The specimens, fabricated with the dimension of $23mm{\times}18mm{\times}70{\mu}m$, were irradiated by neutron fluence from $10^{12}n/cm^2\;to\;10^{18}n/cm^2$ at 343K. Throughout the experiments, it is understood that (1) the X-ray diffraction measurement shows that the change of crystal nature is started at the irradiation of $10^{16}n/cm^2$ and a crystal structure has been severely damaged at the irradiation over $10^{17}n/cm^2$, (2) the analysis of the $M{\ddot{o}}ssbauer$ spectra has shown that magnetic transition phenomena occur at the irradiation over $10^{17}n/cm^2$ and (3) both methods can be utilized as nondestructive test methods for the embrittlement evaluation of materials irradiated by fast neutrons.

  • PDF