• 제목/요약/키워드: the number of coil-turn

검색결과 27건 처리시간 0.035초

매입형 영구자석 전동기의 파라미터 검증을 위한 인덕턴스 산정 (The Calculation of Inductance to verify the Parameters in Interior Permanent Magnet Motor)

  • 이석희;이상호;반지형;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.783-784
    • /
    • 2006
  • In case of a difference exist between the experimental value and estimated value of back-emf, there can be a difference of turn number or residual flux density of permanent maget of the motor. In order to presume the turn number, the average length for each coil is used to calculate the resistance. However in producing the motor, doc to the tension of coil, the outer diameter of coil becomes smaller, and then the resistance estimated by average length for each coil is not correct. Therefore in this paper, through the comparison of experiment value and estimated value of inductance, a method of presuming the turn number and PM's residual flux density of an IPM motor is presented. The inductance of IPM motor changes with the rotor position, therefore the rotor part is taken out and then the inductance in open circuit condition is measured. In the analytical calculation, 3D FEM(Finite Element Method) is used, which can consider the leakage flux of end turns in frinzing effect.

  • PDF

공심인덕터의 제조 및 특성평가 (The Fabrication and Measurement of Air Core Inductor)

  • 정순종;송재성;김현식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1479-1481
    • /
    • 1996
  • The Purpose of this paper is to produce air core inductor and measure its electrical properties for high frequency. Especially we focused attention on the effect of geometrical parameters such as coil width, distance between coils, turn number. In addition, the influence of film morphology at inductor was investigated. Increase of coil width and decrease of turn number resulted in promotion of electric properties.

  • PDF

원통형 동기발전기 회전자의 층간단락에 관한 연구 (Study of Shorted-turn for Cylindrical Synchronous Generator Rotor)

  • 김영준;김장목;이상혁;안진우
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.52-56
    • /
    • 2006
  • This paper describes the methods for the detection of shorted-turn in the rotor of a cylindrical synchronous generator. A search coil is installed in the air-gap to detect the shorted-turn. The occurrence of a fault in the rotor winding results in a decrease of the induced voltages in the stator. And the magnitude of the rotor flux can be estimated by using the search coil and the estimated stator voltages respectively. And the magnitude of the estimated rotor flux is used for discriminating the rotor windings short or not by detecting the magnitude of the rotor flux. The method using a search coil located in the air-gap can detect not only the occurrence of a turn fault but also its position in the rotor winding. But the method using the estimated stator voltages gives the magnitude of the rotor flux, and only the number of a short-turn.

기울어진 덕트 내 헬리컬 코일의 자연대류 열전달 (Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct)

  • 박주현;정범진
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.13-20
    • /
    • 2014
  • 헬리컬 코일이 덕트 내부에 있을 때, 기울기에 따른 자연대류 열전달을 실험적으로 측정하였다. 고부력 조건을 구현하기 위하여 유사성에 기초하여 열전달 실험을 대신하여 물질전달 실험을 수행하였다. RaD 수 $4.55{\times}10^6$에서, 턴(Turn) 수를 1~10, P/D를 1.3~5, 헬리컬 코일의 기울기를 $0^{\circ}{\sim}90^{\circ}$까지 변화시켰다. 헬리컬 코일의 턴 수가 1일 때, 측정된 $Nu_D$ 수는 McAdams의 수평관 자연대류 열전달 상관식과 거의 일치하였다. 기울어진 덕트 내 헬리컬 코일의 자연대류 열전달은 피치, 턴 수, 덕트 높이에 따라 복합적으로 변화하였고 이는 속도 효과, 굴뚝 효과, 예열 효과로 분석되었다. 본 연구의 결과는 Compact heat exchanger에서의 자연대류 열전달에 대한 현상학적 분석에 기여한다.

개선된 자속구속형의 2차 측 권선 방향과 1차 권선수와 2차 권선수의 변화에 따른 사고전류제한 특성 (Current Limiting Characteristics of Improved Flux-Lock Type SFCL According to Winding Direction of Coil 2 and Variable Number of Coil 1 and Coil 2)

  • 김용진;두호익;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제23권9호
    • /
    • pp.714-717
    • /
    • 2010
  • The improved flux-lock type superconducting fault current limiter (SFCL) is composed of a series transformer and superconducting unit of the yttrium-barium-copper-oxide (YBCO) coated conductor. In this paper, we investigated current limiting characteristics through winding direction of coil 2 and variable number of coil 1 and coil 2 in improved flux-lock type SFCL. The better fault current characteristics and the burden of YBCO coated conductor can be confirmed from the experimental result in the higher turn ratio of coil 1 and coil 2 in the additive conditions. In case of subtractive condition, we can confirm a similar result in the same case of experimental conditions. but the burden of YBCO coated conductor has been increased from an increase in winding numbers of coil 2.

단일 권선 FEM 시뮬레이션을 통한 자기유도형 무선전력전송 코일의 효율 최적화 설계 (Coil Design Scheme using Single-Turn FEM Simulation for Efficiency Optimization of Inductive Power Transfer System)

  • 류승하;쫑탄띤;최성진
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.471-480
    • /
    • 2022
  • Inductive power transfer (IPT) is an attractive power transmission solution that is already used in many applications. In the IPT system, optimal coil design is essential to achieve high power efficiency, but the effective design method is yet to be investigated. The inductance formula and finite element method (FEM) are popular means to link the coil geometric parameters and circuit parameters; however, the former lacks generality and accuracy, and the latter consumes much computation time. This study proposes a novel coil design method to achieve speed and generality without much loss of accuracy. By introducing one-turn permeance simulation in each FEM phase combined with curve fitting and optimization by MATLAB in the efficiency calculation phase, the iteration number of FEM can be considerably reduced, and the generality can be retained. The proposed method is verified through a 100 W IPT system experiment.

DC reactor type 고온호전도 한류기의 턴간 절연 특성 (The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

500 W 급 무선전력전송 컨버터의 고효율 설계 방법 (Design Methodology of 500 W Wireless Power Transfer Converter for High Power Transfer Efficiency)

  • 김민아;박화평;정지훈
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.356-363
    • /
    • 2016
  • The design methodology of an adequate input voltage and magnetizing inductance to minimize reactive power is suggested to design a wireless power transfer (WPT) converter for high-power transfer efficiency. To increase the magnetizing inductance, the turn number of the WPT coil is increased, thus causing high parasitic resistance in the WPT coil. Moreover, the high coil resistance produces high conduction loss in the transfer and receive coils. Therefore, the analysis of conduction loss is used in the design of the WPT coil and the operating point of the WPT converter. To verify the proposed design methodology, the mathematical analysis of the conduction loss is presented by experimental results.

지구자기장을 이용한 소구경 탄약 신관용 소형 회전수 계수 센서 (A miniaturized turn-counting sensor using geomagnetism for small-caliber ammunition fuzes)

  • 윤상희;이석우;이영호;오종수
    • 센서학회지
    • /
    • 제16권1호
    • /
    • pp.17-23
    • /
    • 2007
  • This paper presents a miniaturized turn-counting sensor (TCS) where the geomagnetism and high-rpm rotation of ammunition are used to detect the turn number of ammunition for applications to small-caliber turn-counting fuzes. The TCS, composed of cores and a coil, has a robust structure with no moving part for increasing the shock survivability in the gunfire environments of ${\sim}30,000$ g's. The TCS is designed on the basis of the simulation results of an electromagnetic analysis tool, $Maxwell^{(R)}$3D. In experimental study, the static TCS test using a solenoid-coil apparatus and the dynamic TCS test (firing test) have been made. The presented TCS has shown that the induction voltage of $6.5{\;}mV_{P-P}$ is generated at the magnetic flux density of 0.05 mT and the rotational velocity of 30,000 rpm. From the measured signal, the TCS has shown the SNR of 44.0 dB, the nonlinearity of 0.59 % and the frequency-normalized sensitivity of $0.26{\pm}0.01{\;}V/T{\cdot}Hz$ in the temperature range of $-30{\sim}+43^{\circ}C$. Firing test has shown that the TCS can be used as a turn-counting sensor for small-caliber ammunition, verifying the shock survivability of TCS in high-g environments.

고온초전도 한류기용 코일의 턴간 절연 특성 (Turn-to-Turn Dielectric Characteristics of Coils for HTSFCL)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.15-18
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

  • PDF