Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading

  • Lee, Joo-Hee;Cha, Hyun-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권6호
    • /
    • pp.415-421
    • /
    • 2018
  • PURPOSE. This study investigated the effects of abutment screw lengths on screw loosening and removal torque in external connection implants after oblique cyclic loading. MATERIALS AND METHODS. External connection implants were secured with abutment screws to straight abutments. The abutment-implant assemblies were classified into seven groups based on the abutment screw length, with each group consisting of five assemblies. A cyclic load of 300 N was applied at a $30^{\circ}$ angle to the loading axis until one million cycles were achieved. Removal torque values (RTVs) before and after loading, and RTV differences were evaluated. The measured values were analyzed using repeated measures of analysis of variance with the Student-Newman-Keuls multiple comparisons. RESULTS. All assemblies survived the oblique cyclic loading test without screw loosening. There was a significant decrease in the RTVs throughout the observed abutment screw lengths when the abutment-implant assemblies were loaded repeatedly (P<.001). However, the abutment screw length did not show significant difference on the RTVs before and after the experiment when the abutment screw length ranged from 1.4 to 3.8 mm (P=.647). CONCLUSION. Within the limit of this experiment, our results indicate that the abutment screw length did not significantly affect RTV differences after oblique cyclic loading when a minimum length of 1.4 mm (3.5 threads) was engaged. These findings suggest that short abutment screws may yield stable clinical outcomes comparable to long screws in terms of load resistance.

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

A STATISTICAL DESIGN OF SENSITIVITY EXPERIMENTS

  • Lee, Chun-Jin
    • Journal of applied mathematics & informatics
    • /
    • 제6권2호
    • /
    • pp.631-638
    • /
    • 1999
  • Sensitive testing has been widely employed for many years in connection with the development and evaluation explosives detonation devices and propellants. Perhaps its earliest and possibly most important implementation was in biological studies of dosage mortality and response to drugs. Recently sensitivity experiments has been employed in the evaluation of new materials subject to stress in various environments and in delineanation of unstable combustion regions in chemical propulsion systems. This paper discussed a sta-tistical development of sensitivity testing.

A Study of Impedance Matching Circuit Design for PLC

  • Kim, Gi-Rae
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.453-458
    • /
    • 2009
  • This paper presents two methods of designing a Broadband Impedance Matching (BIM) circuit for maximizing a power line communication (PLC) equipment (or Modem) signal injection into its load at any power line connection port. This optimal (BIM) circuit design is achieved in two phases: Butterworth gain function and Tchebycheff gain function. According to the comparison of simulation and practical results, the performances of two gain functions on BIM are discussed.

불균형 휨모멘트를 받는 플랫플레이트-기둥 접합부의 편심전단강도 (Strength Model for Eccentric Shear of Flat Plate-Column Connections under Unbalanced Moment)

  • 최경규;박홍근
    • 콘크리트학회논문집
    • /
    • 제16권2호
    • /
    • pp.229-240
    • /
    • 2004
  • 불균형 휨모멘트를 재하받는 플랫플레이트-기둥 접합부의 편심전단강도와 모멘트강도를 규명하기 위해 그동안 많은 실험연구가 수행되어 왔다. 기존 실험들은 서로 다른 실험방식을 사용하고 있는데, 접합부의 전단강도는 실험방식에 따라 차이가 있는 것으로 나타났다. 따라서 기존 실험에 근거하여 개발된 현행 설계기준들은 플랫플레이트의 강도를 정확히 설명하고 있지 못한 실정이다. 선행 연구에서는 연속 플랫플레이트에 대한 비선형 유한요소해석에 근거하여, 슬래브-기둥 접합부에 패한 새로운 설계방법을 개발하였다. 그러나 제안된 설계방법에서는 휨모멘트 강도산정에 필요한 접합부 편심강도를 경험식에 의존하여 산정하고 있다. 본 연구에서는, 접합부 파괴 메카니즘을 분석하기 위해서, Rankine 재료파괴기준을 이용하는 이론적인 접근법을 채택하였다. 분석결과에 근거하여 개선된 편심전단강도모델이 개발되었고, 기존 실험과의 비교를 통해 검증되었다. 개발된 강도식을 이용하여, 선행연구에서 개발된 설계방법을 재검증하였다.

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • 제12권1호
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

스킵 연결 형태 기반의 손 관절 2D 및 3D 검출 기법 (2D and 3D Hand Pose Estimation Based on Skip Connection Form)

  • 구종회;김미경;차의영
    • 한국정보통신학회논문지
    • /
    • 제24권12호
    • /
    • pp.1574-1580
    • /
    • 2020
  • 기존의 신체 인식 방법은 특수한 기기를 사용하거나 이미지로부터 영상처리를 통해 검출하는 방법들이 있다. 특수 기기를 사용할 경우 기기를 사용할 수 있는 환경이 제약되고 기기의 비용이 많이 든다는 단점이 있다. 카메라와 영상처리를 사용할 경우 환경의 제약과 비용이 낮아지는 장점이 있지만, 성능이 떨어진다. 이런 단점을 해결하기 위해 카메라와 합성 곱 심층 신경망을 사용한 신체 인식 방법들이 연구되었다. 합성 곱 심층 신경망의 성능을 올리기 위해 다양한 기법들이 제안되었다. 본 논문에서는 합성 곱 심층 신경망의 성능을 올리기 위한 기법 중 스킵 연결을 다양한 형태로 사용하여 스킵 연결이 손 검출 망에 끼치는 영향을 실험하였다. 실험을 통해 기본 스킵 연결 이외 추가적인 스킵 연결의 존재가 성능에 나은 영향을 끼치고 하향 스킵 연결만 추가된 망이 가장 나은 성능을 보임을 확인하였다.

Narrow-diameter implants with conical connection for restoring the posterior edentulous region

  • Woo, In-Hee;Kim, Ju-Won;Kang, So-Young;Kim, Young-Hee;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.31.1-31.7
    • /
    • 2016
  • Background: The objective of this retrospective study was to show results from platform-switched narrow-diameter implants in the posterior edentulous region, which we followed up for more than 1 year after functional loading. Methods: Ninety-eight narrow implants were inserted into 66 patients. After healing, fixed implant-supported prostheses were delivered to the patients, and Periotest and radiographic examinations were performed. After the first year of loading, the implant outcome was again evaluated clinically and radiographically using the Periotest analysis. Crestal bone loss and Periotest values (PTVs) were used to evaluate the effect of surgery, prosthesis, implant, and a host-related factor. A general linear model was used to statistically detect variables statistically associated with crestal bone loss and Periotest value. Results: We followed up on the implants over 1 to 4 years after loading; their survival rate was 100 %, and pronounced differences from PTVs were noted among jaw location, bone quality, and loading period. No difference was detected in bone loss among the variables studied. Bone loss after functional loading was $0.14{\pm}0.39mm$. The stability value from the Periotest was $-3.29{\pm}0.50$. Conclusions: Within the limitations of this study, judicious use of platform-switched narrow implants with a conical connection must be considered an alternative for wide-diameter implants to restore a posterior edentulous region.

비선형 유한요소법을 이용한 메탈 플레이트 접합부의 거동해석 (Analysis of Behavior of Metal Plate Connection by Nonlinear Finite Element Method)

  • 현재혁;김광철;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권3호
    • /
    • pp.23-30
    • /
    • 1999
  • 경골 목조 트러스를 접합하는데 가장 널리 사용되는 메탈 플레이트 접합부의 거동을 해석하기 위한 연구가 많이 수행되어왔다. 유한요소법을 사용한 해석은 그 연구들중의 하나이다. 선형 모델을 사용한 유한요소법은 하중-변위 곡선의 초기 경사를 예측하는데는 유효하게 사용될 수 있다. 하지만, 하중이 증가할수록 예측된 변위는 실험치에 비해 과예측이 된다. 따라서 선형 모델을 비선형부분을 예측하는데는 사용할 수 없다. 실제 거동을 더욱 정확하게 예측하기 위해, 본 연구에서는 비선형 항을 유한요소 모델에 첨가시켰다. EA와 AA 형태에서는 예측치와 실험치간에 고도의 유사성을 보여주었다. 하지만, EE와 AE 형태에서는 곡선의 비선형 부분에서 실험치와 예측치가 약간의 차이를 보여주었다. 이러한 결과는 슬립의 효과를 충분히 반영하지 못한 것에 기인한 것으로 추측된다. 결과적으로 메틸플레이트 접합부의 거동에 있어서 비선형 해석의 정확도를 증진시키기 위해서는 반드시 슬립의 효과가 고려되어야 할 것이다.

  • PDF

동적 연결 그래프를 이용한 자동 문서 요약 시스템 (A Document Summarization System Using Dynamic Connection Graph)

  • 송원문;김영진;김은주;김명원
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권1호
    • /
    • pp.62-69
    • /
    • 2009
  • 문서 요약은 쉽고 빠르게 문서의 내용을 파악할 수 있도록 방대한 내용을 가지는 다양한 형태의 문서로부터 핵심 내용만을 추출하거나 생성하여 제공하는 것을 목적으로 한다. 본 논문에서는 효율적 문서 요약을 위해 주어진 문서의 평균 문장 길이(핵심어 개수)를 고려하여 문장 간의 핵심어 유사도를 나타내는 연결 그래프를 생성하고 분석하여 요약을 생성하는 기법을 제안한다. 또한 이러한 기법을 이용하여 응용 프로그램 문서로부터 자동으로 요약을 생성하는 자동 문서 요약 시스템을 개발한다. 제안한 방법의 객관적인 요약 성능 측정을 위해 정확한 요약문이 실린 20개의 테스트 문서를 이용하여 생성된 요약에 대해 precision(정확률)과 recall(재현율), F-measure를 측정하였으며, 실험 결과를 통해 기존 기법에 비해 우수한 요약 성능을 보임을 증명하였다.