• 제목/요약/키워드: the methods of connection

검색결과 1,360건 처리시간 0.029초

사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석 (CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector)

  • 구성모;오원철;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

주요 신경과의 연결이 없이 발생한 긴손바닥근의 신경초종 (Neurilemoma Localized in the Palmaris Longus Tendon with no Connection to the Major Nerve Trunk)

  • 박정용;정성노;손원일;권호
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.498-500
    • /
    • 2011
  • Purpose: Neurilemoma is benign tumor of the nerve sheath which arises from Schwann cells. It is usually formed along the path of a peripheral nerve but is rarely separate from normal nerve fascicles. We experienced a patient with an isolated neurilemoma localized in the palmaris longus tendon with no connection to the major nerve trunk, which was in an unusual location and has never been reported. We report our case with the review of the literature. Methods: A 23-year-old female visited our clinic with mild pain on the mass at the flexor area of the right wrist which had been present for about one year. The physical examination revealed a $1{\times}1cm$ sized subcutaneous mass at the flexor area of the right wrist. Sonography and computed tomography showed an ovoid, superficial solid mass on the palmaris longus tendon. Upon surgical excision, a $1{\times}0.5cm$ sized mass attached to the palmaris longus tendon was found. The tumor had no connection with the median nerve and was detached easily from the palmaris longus tendon. Results: Histological examination demonstrated the mass to be a neurilemoma, which consists of spindle shaped cells with oval elongated nuclei arranged fascicles. No sensory dysfunction or evidence of recurrence was found during the 12 months of postoperative follow-up. Conclusion: We experienced a rare case of neurilemoma attached to the palmaris longus tendon with no connection to the major nerve trunk. We wish to emphasize its unusual location through our case and hope to expand our spectrum in exploring the upper extremity mass.

역대 정권별 보건복지부 장관의 취임사를 통한 보건행정 및 정책 비교분석 (Comparative Analysis of Health Administration and Policy through Inaugural Address of Minister of Health and Welfare)

  • 김유호
    • Journal of health informatics and statistics
    • /
    • 제43권4호
    • /
    • pp.274-281
    • /
    • 2018
  • Objectives: The purpose of this study is to comprehensively compare the trends of health administration and health policy in the field of health care using the semantic network analysis in the inaugural address of the Ministry of Health and Welfare of each regime in Korea. Methods: This study used a language network analysis method that uses Korean Key Words In Context (KrKwic) program and NetMiner program in sequence. The analysis was conducted by Minister Hwa-joong Kim during the Moo-hyun Roh government, Minister Jae-hee Jeon during the Myung-bak Lee government, Minister Young Jin of Geun-hye Park government and Government Jae-in Moon's inaugural address of Neung-Hoo Park Minister, respectively. Results: The key words differentiated by each regime are that the Moo-hyun Roh Government's Minister Hwa-joong Kim had high connection centrality values in the words 'balanced development', 'comprehensive' and 'reform'. Minister Jae-Hee Jeon of Myung-bak Lee Government had high connection centrality values in the words 'poverty' and 'return'. In the case of Minister Young Jin of Geun-hye Park Government had high connection centrality values in the words 'demand', 'Customized' and 'Life cycle'. In the case of Minister Neung-Hoo Park of Jae In Moon Government had high connection centrality values in the words 'Welfare state', 'Embracing' and 'Soundness'. Conclusions: If the role of health administration in the health care field and the health care policies are constantly changed according to the policies of each regime, it is inconsistent and it is difficult to approach from the long term perspective for public health promotion. In the future, health policy should be developed and implemented with a long-term perspective and consistency based on the consensus and participation of the people with less influence on the change and direction of each government's policies.

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

An experimental study of the behaviour of double sided bolted billet connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.603-622
    • /
    • 2018
  • Precast concrete structures are erected from individual prefabricated components, which are assembled on-site using different types of connections. In the present design of these structures, beam-to-column connections are assumed pin jointed. Bolted billet beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is currently limited information concerning their detailed structural behaviour under vertical loadings. The experimental work has involved the determination of moment-relative rotation relationships for semi-rigid precast concrete connections in full-scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and bolt arrangements conformed to successful commercial practice. Proprietary hollow core floor slabs were tied to the beams by 2T25 tensile reinforcing bars, which also provide the in-plane continuity across the connections. The contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. The flexural strength of the connections in the double-sided tests was at least 0.93 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.94 to 1.94 times the flexural stiffness of the attached beam. In general, the double-sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided bolted billet connection test results are presented in this paper. The behaviour of single sided bolted billet connection test results is the subject of another paper.

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

  • Jo, Jae-Young;Yang, Dong-Seok;Huh, Jung-Bo;Heo, Jae-Chan;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.491-497
    • /
    • 2014
  • PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구 (A STUDY ON THE VARIOUS IMPLANT SYSTEMS USING THE FINITE ELEMENT STRESS ANALYSIS)

  • 유성현;박원희;박주진;이영수
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.207-216
    • /
    • 2006
  • Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently the fixture that has tapered form of internal connection is often selected. However the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture ; $Br{\aa}nemark$, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analysis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system. cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of $Br{\aa}nemark$ system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than $Br{\aa}nemark$ system.

천장 브래킷형 모듈러 시스템의 브래킷 길이와 볼트에 따른 내진성능평가 (Seismic Performance Evaluation of the Ceiling Bracket-type Modular System with Various Bracket Lengths and Bolt Types)

  • 곽의신;강창훈;손수덕;이승재
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.25-33
    • /
    • 2018
  • In regard to modular systems, new methods, as well as middle and high-story unit design ideas, are currently being studied. These studies need to focus on the enhanced stiffness and seismic performance of these connections, and see that the development of fully restrained moment connections can improve the seismic performance. For this reason, this study evaluates the performance of the connections of the ceiling bracket-typed modular system through repeated loading tests and analyses. In order to compare them with these modular units, new unit specimens with the bracket connection being different from that of the traditional modular unit specimens were designed, and the results of repeated loading tests were analyzed. In the traditional units, the structural performances of both welding connection and bolt connection were evaluated. In regard to the testing results, the initial stiffness of the hysteresis curve was compared with the theoretical initial stiffness, and the features of all specimens were also analyzed with regard to the maximum moment. In addition, the test results were examined with regard to the connection flexural strength of the steel special moment frame specified under the construction criteria KBC2016. The connections, which were proposed in the test results, were found to be fully restrained moment connections for designing strong column-weak beams and meeting the requirements of seismic performance of special moment frames.

확대기초의 신구 콘크리트 접합 모형실험 (Mock-Up Test for Connection of New-Old Concrete of Footing)

  • 황철성;유성원
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.66-71
    • /
    • 2018
  • 일반적으로 소구경 말뚝을 이용한 기존교각의 확대보강을 시행하는 경우 접합부의 일체성을 유지하기 위해 후 설치 앵커 중에서 이형철근을 사용한 부착식 앵커를 사용한다. 그러나 부착식 앵커의 경우 접합재의 종류 등에 따라 성능이 크게 좌우됨에도 불구하고 기계식 앵커와는 달리 설계방법의 표준화와 함께 적절한 성능평가를 위한 표준적인 실험방법도 제시되지 않고 있는 실정이다. 이에 따라 본 연구에서는 철근의 겹이음 및 앵커철근을 이용한 모형실험을 실시하여 부착식 앵커의 성능에 대한 평가를 수행하였다. 실험 결과, 접합하지 않은 시험체의 구조 성능이 가장 우수하게 나타났으며, 파괴양상은 펀칭전단 파괴로 나타났다. 연결되지 않은 부재가 연결된 부재보다는 부재 끝단의 처짐이 더 작게 발생되며, 큰 크기로 연결된 부재의 처짐이 작게 연결된 부재의 처짐보다는 크게 나타나, 하중이 증가할수록 앵커 철근 또는 겹이음 철근의 미끌림 등의 현상이 발생될 가능성이 큰 것으로 나타났다.