Browse > Article
http://dx.doi.org/10.14190/JRCR.2018.6.1.66

Mock-Up Test for Connection of New-Old Concrete of Footing  

Hwang, Chul-Sung (Dept. of Civil and Environmental Eng. Gachon University)
Yoo, Sung-Won (Dept. of Civil and Environmental Eng. Gachon University)
Publication Information
Journal of the Korean Recycled Construction Resources Institute / v.6, no.1, 2018 , pp. 66-71 More about this Journal
Abstract
In general, when an existing pier is enlarged and reinforced using a small diameter pile, bonded anchor with deformed reinforcing bars is used to maintain the integrity of the joint. However, in the case of bonded anchors, the performance depends largely on the type of joint material. Nevertheless, unlike mechanical anchors, there is no standard method for designing appropriate design methods and proper performance evaluation. Therefore, in this study, the performance of the anchoring anchor was evaluated by performing a model experiment using the reinforcing bars and anchor reinforcing bars. Experimental results show that the structural performance of the unbonded specimen is the best, and the failure mode is the punching shear failure. The deflection of the end of the member is smaller than that of the unconnected member, The deflection of the connected member is larger than the deflection of the small connected member. As the load increases, the possibility of slippage of the anchor steel or fold connection rebar is high.
Keywords
Connection; Fold connection; Anchor; Mock-up test;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ACI committee 345. (2015). ACI Practice Manual 345.2R-15: Guide for Widening Highway Bridge, ACI, Detroit.
2 Azizinamini, A., Stark, M., Roller, J.J., Ghosh, S.K. (1993). Bond performance of reinforcing bars embedded in high-strength concrete, ACI Structural Journal, 90(5), 554-561.
3 Darwin, D., McCane, S.L., Idun, E.K., Schoenekase, S.P. (1992). Development length criteria: bars not confined by transverse reinforcement, ACI Structural Journal, 89(6), 709-720.
4 Sozen, M.A., Moehle, J.P. (1990). Development and Lap-Splice Lengths for Deformed Reinforcing Bars in Concrete, University, IL and Berkely, CA.
5 Oh, B.H., Kang, Y.J., Lee, S.L., Bang, G.S. (1990). An experimental study on the bond characteristics of reinforced concrete structures, Korea Concrete Institute, 2(4), 99-107 [in Korean].
6 Orangon, C.O., Jirsa, J.O., Breen, J.E. (1977). Reevaluation of Test Data on Development Length and Splice, ACI Journal, Proceedings, 74(3), 114-122.
7 Choi, O.C., Kim, C.H., Shin, Y.S., Hong, G.S. (1994). Performance tests of epoxy-coated reinforcing bars: mechanical properties, Korea Concrete Institute, 6(3), 173-179 [in Korean].
8 ACI committee 318. (2012). Building Code Requirement for Reinforced Concrete(318-12), ACI, Detroit.