• Title/Summary/Keyword: the mandibular first molar

Search Result 381, Processing Time 0.039 seconds

REGIONAL ODONTODYSPLASIA : CASE REPORT (국소적 치아 이형성증(Regional odontodysplasia)에 대한 증례)

  • Lee, Jae-Ho;Cho, Jae-Hyun;Kim, Ki-Dug;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.175-179
    • /
    • 2001
  • Regional odontodysplasia is a relatively rare condition in which both enamel and dentin are hypoplastic and hypocalcified. The result is localized arrest in tooth development. The etiology of regional odontodysplasia is uncertain, but, disturbance in vascular supply, somatic mutation, latent virus infection, trauma, hyperpyrexia, irradiation, nutrition, metabolic disorders and hereditary transmission are supported to be etiologic factors. Females are more often affected than males. (1.4 : 1). The maxillary arch is more often affected than the mandibular arch with the maxillary left quadrant being the most commonly involved. Affected teeth are hypoplastic, typically discolored yellow or yellowish brown, smaller in size and display a variety of surface marking including pitting and grooving. Radiographically, the teeth affected have been described to have a "ghost like" appearance or "fuzzy" appearance. Pulp calcification and denticles may be present within the pulp chambers of the affected teeth. In it's case, a 2 years old male visited for a treatment of uneruption of lower right teeth. Partial eruption of lower right deciduous central incisor and unerupted deciduous lateral incisor, deciduous canine and deciduous first molar showed severly delayed eruption state. On radiographic appearance, "Ghost like appearance", shortened root and opened apexes on lower right region were observed. It was suspected regional odontodysplasia with clinical and radiographic condition.

  • PDF

DENTAL TREATMENT IN A PATIENT WITH PIERRE ROBIN SYNDROME UNDER GENERAL ANESTHESIA : A CASE REPORT (피에르 로빈 증후군 환아의 전신마취 하 치아우식 치료 증례 보고)

  • Ryu, Jiyeon;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Lee, Sang-Hoon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.12 no.2
    • /
    • pp.87-91
    • /
    • 2016
  • Pierre Robin syndrome (PRS) is characterized by the triad of congenital mandibular hypoplasia, glossoptosis and cleft palate. Infant PRS patients are frequently suffering from upper airway obstruction, gastroesophageal reflux and growth retardation caused by above mentioned problems. We report a dental caries treatment of 3-year old girl with Pierre Robin syndrome with multiple caries. The cause of multiple caries was mainly presumed as patient's eating habit caused by her general condition. She had some feeding problems and had history of gastric tube. She was still using milk bottle and took more than an hour to finish a meal. The treatment was performed under general anesthesia considering patient's condition; mild autism, poor cooperation and respiratory problem due to micrognathia. Severely affected upper incisors were treated with pulp treatment and restored with zirconia crown for esthetic purpose. Lower incisors were treated with pulp treatment and restored with composite resin. Upper right first primary molar was restored with stainless steel crown and other primary molars were treated with composite resin. There were no postoperative complications. According to her parents, the patient's compliance to oral hygiene management was greatly improved after the treatment since she was very pleased with the esthetic result and highly motivated by her looks. The treatment without sedation or general anesthesia would be possible once the airway is improved as the mandible grows.

A MORPHOMETRIC STUDY ON THE PRIMARY MOLARS AND PREFORMED STAINLESS STEEL CROWN (유구치 치관 및 기성금속관의 크기에 관한 계측학적 연구)

  • Choi, Ji-Eun;Cheong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.355-362
    • /
    • 2001
  • Data derived from odontometric studies are useful in many areas. Especially crown diameter of primary teeth is important in not only anthropology but also clinical dentistry. The purposes of this study were to compare diameters of primary molars of Korean children with those of preformed stainless steel crown, and examine racial characteristics of primary molars of Korean children. The mesiodistal and buccolingual diameters of primary molars were measured on dental casts taken from 235 children(male 105, female 131), with digital calipers. And the data were compared with those of preformed stainless steel crowns. The results were as follows; 1. No significant difference was observed between the right and left members of antimeric teeth and all primary molars of male were larger than those of female. 2. The diameters of primary molars of Korean are smaller than those of Austrailian aborigines and there was significant difference between diameters of primary molars of Korean and those of other populations. 3. There were size differences between diameters of maxillary, mandibular first molar and preformed stainless steel crown than other primary molars, relatively.

  • PDF

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

A STUDY OF THE STRESS DISTRIBUTION OF THE ABUTMENT AND SUPPORTING TISSUES ACCORDING TO THE SLOPES AND TYPES OF CHIDING FLAMES OF THE LAST ABUTMENT IN DISTAL EXTENSION REMOVABLE PARTIAL DENTURE USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (국소의치 최후방 지대치 유도면의 기울기와 형태가 지대치 및 지지조직의 응력분산에 미치는 영향)

  • Kim, Yang-Kyo;Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.581-596
    • /
    • 1999
  • The purpose of this study was to investigate the stress distribution of the abutment and sup-porting tissues according to the slopes and types of the guiding plane of distal extension removable partial dentures. The 3-dimensional finite element method was used and the finite element models were prepared as follows. Model I : Kratochvil type guiding plane with $90^{\circ}$ to residual ridge Model II : Kratochvil type guiding plane with $95^{\circ}$ to residual ridge Model III : Kratochvil type guiding plane with $100^{\circ}$ to residual ridge Model IV : Krol type guiding plane with $90^{\circ}$ to residual ridge Distal extension partial denture which right mandibular first and second molar were lost was used and the second premolar was prepared as primary abutment with RPI type retainer. Then 150N of compressive force was applied to central fossae of the first and second molars and von Mises stress and displacement were measured. The results were as follows 1. Model I and Model IV showed a similar stress distribution pattern and the stress was concentrated on the apex of the root of the abutment. 2. The stress was increased and concentrated on mesial side of the root of the abutment in Model II. The stress was concentrated on buccal and mesiobuccal side of the root of the abutment in Model IV. 3. In Model I, the root of the abutment displaced and twisted a little in clockwise. In Model IV, the root of the abutment displaced to distolingually at apical region of the root and mesiobuccally at cervical region of the root. 4. In Model II, the root of the abutment displaced to mesiolingually at apical region of the root and more displaced and twisted in counterclockwise at cervical region of the root. In Model III, the root of the abutment displaced to mesiobucally at apical region of the root and more displaced and twisted in clockwise at cervical region of the root.

  • PDF

THE REACTION OF BONE REGENERATE TO THE VARIOUS FORCE RATIO AND PERIODS ON DISTRACTION OSTEOGENESIS WITH COMBINED DISTRACTION FORCE AND COMPRESSION FORCE (수축력과 신장력을 병용한 골신장술에서의 다양한 힘의 비와 부여시기에 따른 신연골 반응)

  • Kim, Uk-Kyu;Shin, Sang-Hun;Chung, In-Kyo;Kim, Cheol-Hun;Huo, Jun;Yun, Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.5
    • /
    • pp.403-414
    • /
    • 2005
  • The purpose of this study was to identify the effectiveness of the modified distraction osteogenesis (DO) method with the concept of overdistraction and compression stimulation which have been previously suggested by the authors in 2002 and to explore the optimal distraction-compression ratio and appropriate latency period for the compression force application during consolidation. The experimental specimens were assessed with radiography, histologic findings, and dual energy x-ray absorptiometry (DEXA) after the conventional DO method and the modified DO technique had been applied on rat mandibles. Total 60 rats were used for the study. In experimental group of 54 adult rats, mandibular osteotomies between the first and second molar areas were performed and customized external distractors were applied. The surgeries on 6 rats of control group also were done with same osteotomy technique and DO device application. Final amount of distraction was set-up as 2 mm on both groups. But, in a experimental group of 54 rats, distraction osteogenesis with a compression force were performed with the different distraction-compression ratio and variant latency periods for compression. The three ratio-subgroups were made as distraction 4 mm group with compression 2 mm, distraction 3 mm group with compression 1 mm, and distraction 2.5 mm group with compression 0.5 mm. In addition, The three subgroups with 3, 7, 11 days latency period prior compression were allocated on each ratio-subgroups. Total 9 subgroups consisted of 6 rats on each subgroup. In control group of 6 rats, conventional distraction technique were routinely performed. The rats of control groups were sacrificed on postoperative 3, 6 weeks after 2 mm distraction. The rats in the experimental groups also were sacrificed on the same euthanasia days of control groups to compare the wound healing. Final available specimens were 55 rats except 5 due to osteomyelitis, device dislodgement. Distraction-compression combined group on 6 weeks generally had showed increased bone mineral density than the same period group of conventional distraction technique on the DEXA study. More matured lamellar bone state and extended trabecular pattern in the combined group than those of control group were also observed in the histologic findings on 6 weeks. In the distraction-compression combined groups, the bone density of 2.5 mm distraction subgroups with 0.5 mm compression showed the highest value on the DEXA study among various force ratio groups. In the distraction-compression combined groups, the bone density of 3 day latency period subgroups showed the highest value on the DEXA study among various latency period groups for the compression application. From this study, we could deduce that 1/5 force ratio for the compression versus distraction, 3 day latency period prior compression application would be the most effective condition if modified distraction osteogenesis technique might be applicable. The modified DO method with a compression force may improve the quality of bone regenerate and shorten total treatment period in comparison with conventional DO technique clinically.

Comparison of the effect of removing artificial dental plaque depending on various interdental cleaning products on the interdental surface of zirconia crowns (치간 세정 용품에 따른 지르코니아 크라운 인접면의 인공 치면 세균막 제거 효과)

  • Kim, Hyun-Wook;Song, Ha-Kyung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose. The purpose of this study is to compare five interdental cleansing products' effectiveness on removing artificial dental plaque on the interdental space of zirconia crowns. Materials and methods. A model with abutments on the right mandibular second premolar and first molar were prepared. 10 zirconia crowns for each abutment were fabricated. After applying artificial dental plaque between the zirconia crowns, a single clinician attempted to remove the plaque with five products: interdental toothbrush, end-tuft toothbrush, dental floss, Easypick, Water pik. They were conducted 10 times per group. The aspect and area of removed surfaces were analyzed using images taken with a digital camera. One factor analysis of variance was performed as a statistical analysis, and a post-hoc test was performed using the Scheffé method (P < .05). Results. There were differences in the area and the pattern according to the characteristics of the products. The largest area, including the marginal portion, was removed in the dental floss group. Interdental toothbrush group was the most effective in removing the dental plaque at the marginal portion. Easypick was less effective than the interdental toothbrush. The end-tuft toothbrush showed better results than other products in cleansing mesiobuccal and distobuccal area, but could not cleanse the area directly below the contact point. In Water pik group, artificial dental plaque was scarcely removed. The removal rate of artificial dental plaque was in the order of floss (69.47%), end-tuft toothbrush (49.36%), interdental toothbrush (44.20%), Easy pick (13.04%), and Water pik (0.59%). Conclusion. Dental floss showed the highest removal rate in the interdental space restored with zirconia crowns, while interdental toothbrush was the most effective in removing the dental plaque at the marginal portion.

Evaluation of the stress distribution in the external hexagon implant system with different hexagon height by FEM-3D (임플란트 hexagon 높이에 따른 임플란트와 주위 조직의 응력분포 평가)

  • Park, Seong-Jae;Kim, Joo-Hyeun;Kim, So-Yeun;Yun, Mi-Jung;Ko, Sok-Min;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.36-43
    • /
    • 2012
  • Purpose: To analyze the stress distribution of the implant and its supporting structures through 3D finite elements analysis for implants with different hexagon heights and to make the assessment of the mechanical stability and the effect of the elements. Materials and methods: Infinite elements modeling with CAD data was designed. The modeling was done as follows; an external connection type ${\phi}4.0mm{\times}11.5mm$ Osstem$^{(R)}$ USII (Osstem Co., Pusan, Korea) implant system was used, the implant was planted in the mandibular first molar region with appropriate prosthetic restoration, the hexagon (implant fixture's external connection) height of 0.0, 0.7, 1.2, and 1.5 mm were applied. ABAQUS 6.4 (ABAQUS, Inc., Providence, USA) was used to calculate the stress value. The force distribution via color distribution on each experimental group's implant fixture and titanium screw was studied based on the equivalent stress (von Mises stress). The maximum stress level of each element (crown, implant screw, implant fixture, cortical bone and cancellous bone) was compared. Results: The hexagonal height of the implant with external connection had an influence on the stress distribution of the fixture, screw and upper prosthesis and the surrounding supporting bone. As the hexagon height increased, the stress was well distributed and there was a decrease in the maximum stress value. If the height of the hexagon reached over 1.2mm, there was no significant influence on the stress distribution. Conclusion: For implants with external connections, a hexagon is vital for stress distribution. As the height of the hexagon increased, the more effective stress distribution was observed.

Three-dimensional finite element analysis for the effect of retentive groove design on joint strength of casting connection (유지구 설계가 주조연결강도에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Kim, Jung-Woo;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.29-38
    • /
    • 2009
  • Statement of problem: A casting connection technique is widely used for repair, correction and addition to base metal framework. However, a casting connection technique may increase the risk of failure in clinical situations when high stresses exist. Purpose: The purpose of this study was to investigate the mechanical retentive groove design comparatively to increase the joint strength by using the three-dimensional finite element analysis model of a 3-unit fixed partial denture. Material and methods: Ten finite element models were constructed. (Model A: One retentive groove, Model B: Two retentive grooves, Model C: Three retentive grooves, Model D: Four retentive grooves, Model E: One horizontal groove and two vertical grooves, Model F: Two horizontal grooves and one vertical groove, Model G: One groove with the enlarged dimension, Model H: Two grooves with the enlarged dimension, Model I: One groove with the increased height, Model J: One groove with the increased width of base). The vertical force was applied to the mesial and the distal fossa to the casting connection of mandibular first molar. Results: The main factors, affecting joint strength of casting connection were both the retention between the primary cast and the secondary cast and the thickness of the primary cast remaining after preparing retentive groove. The increase of retentive force, according to the numbers and the dimension of retentive groove had an effect on distributing stress. However, in some cases, the increase of retentive force resulted in the increase of stress by reducing thickness of the primary cast in the connection area. Conclusion: The design of retentive groove that limits number of retentive groove for metal thickness and increases the depth of retentive groove for retention is highly recommended.

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.