Comparison Study of Static and Dynamic Plantar Foot Pressure between Chronic Low Back Pain Patients and Normal Adults (만성 요통 환자와 정상 성인의 정적, 동적 족저압 비교 연구)

  • Lee, Jeon-Hyeong;Kim, Gi-Chul;Seo, Hyun-Kyu;Park, Youn-Ki
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.1
    • /
    • pp.49-54
    • /
    • 2013
  • Background: The purposed of this study is to examine the static and dynamic plantar foot pressure in chronic low back pain patients and normal adults. Methods: The subjects were divided into a group of 30 patients with chronic low back pain and a control group of 30 healthy persons. While static posture and dynamic posture at comfortable walking speeds, the low back pain group and the control group measured their plantar foot pressure and the trajectory of their center of pressure (COP) using the Matscan(R) system. Independent t-tests were measured to compare differences in plantar foot pressure characteristics between the left side and right side of the low back pain group and the control group. Results: In the comparison of differences in plantar foot pressure characteristics between the left side and right side of the low back pain group and the control group, the anteroposterior (AP) displacement of COP showed significant differences (p<.05). Although the low back pain group and the control group did not show any significant differences in leg length, weight distribution, mediolateral (ML) displacement of COP, static contract area, dynamic contract areas (p>.05), increases in the contract area values were shown in the hind foot in general. Conclusion: In this study, it was shown that patients with chronic low back pain were walking with short AP displacement of the COP as a compensatory action to avoid pain.

  • PDF

Biometrics Based on Multi-View Features of Teeth Using Principal Component Analysis (주성분분석을 이용한 치아의 다면 특징 기반 생체식별)

  • Chang, Chan-Wuk;Kim, Myung-Su;Shin, Young-Suk
    • Korean Journal of Cognitive Science
    • /
    • v.18 no.4
    • /
    • pp.445-455
    • /
    • 2007
  • We present a new biometric identification system based on multi-view features of teeth using principal components analysis(PCA). The multi-view features of teeth consist of the frontal view, the left side view and the right side view. In this paper, we try to stan the foundations of a dental biometrics for secure access in real life environment. We took the pictures of the three views teeth in the experimental environment designed specially and 42 principal components as the features for individual identification were developed. The classification for individual identification based on the nearest neighbor(NN) algorithm is created with the distance between the multi-view teeth and the multi-view teeth rotated. The identification performance after rotating two degree of test data is 95.2% on the left side view teeth and 91.3% on the right side view teeth as the average values.

  • PDF

Human Spatial Cognition Using Visual and Auditory Stimulation

  • Yu, Mi;Piao, Yong-Jun;Kim, Yong-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.41-45
    • /
    • 2006
  • This paper deals with human spatial cognition using visual and auditory stimulation. More specially, this investigation is to observe the relationship between the head and the eye motor system for the localization of visual target direction in space and to try to describe what is the role of right-side versus left-side pinna. In the experiment of visual stimulation, nineteen red LEDs (Luminescent Diodes, Brightness: $210\;cd/^2$) arrayed in the horizontal plane of the surrounding panel are used. Here the LEDs are located 10 degrees apart from each other. Physiological parameters such as EOG (Electro-Oculography), head movement, and their synergic control are measured by BIOPAC system and 3SPACE FASTRAK. In the experiment of auditory stimulation, one side of the pinna function was distorted intentionally by inserting a short tube in the ear canal. The localization error caused by right and left side pinna distortion was investigated as well. Since a laser pointer showed much less error (0.5%) in localizing target position than FASTRAK (30%) that has been generally used, a laser pointer was used for the pointing task. It was found that harmonic components were not essential for auditory target localization. However, non-harmonic nearby frequency components was found to be more important in localizing the target direction of sound. We have found that the right pinna carries out one of the most important functions in localizing target direction and pure tone with only one frequency component is confusing to be localized. It was also found that the latency time is shorter in self moved tracking (SMT) than eye alone tracking (EAT) and eye hand tracking (EHT). These results can be used in further study on the characterization of human spatial cognition.

A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path (하악운동 회전량과 과로의 형태에 관한 연구)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF

8-Straight Line Directions Recognition Algorithm for Hand Gestures Using Coordinate Information (좌표 정보를 이용한 손동작 직선 8 방향 인식 알고리즘)

  • SODGEREL, BYAMBASUREN;Kim, Yong-Ki;Kim, Mi-Hye
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.259-267
    • /
    • 2015
  • In this paper, we proposed the straight line determination method and the algorithm for 8 directions determination of straight line using the coordinate information and the property of trigonometric function. We conduct an experiment that is 8 hand gestures are carried out 100 times each, a total of 800 times. And the accuracy for the 8 derection determination algorithm is showed the diagonal direction to the left upper side shows the highest accuracy as 92%, and the direction to the left side, the diagonal direction to the right upper side and the diagonal direction to the right bottom side show the lowest accuracy as 82%. This method with coordinate information through image processing than the existing recognizer and the recognition through learning process is possible using a hand gesture recognition gesture.

A comparison study of vessel twisting by different microsurgical suture techniques in a chicken wing artery side to side bypass training model

  • Junho Jung;Donghwan Jeong
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.3
    • /
    • pp.260-266
    • /
    • 2023
  • Objective: Microvascular anastomosis, particularly side-to-side (STS) bypass, is a complex surgical procedure. While several suture techniques exist, none of them is superior to the others. We assessed the association between various STS bypass techniques and vessel twisting using chicken wing training models. Methods: Three suture techniques were compared over an anterior wall suture procedure. The unidirectional continuous suture (UCS) group used a downward "right-to-left" continuous suture. The reverse continuous suture (RCS) group used a downward "left-to-right" continuous suture. The interrupted suture (IS) group used the standard interrupted suture. The number of samples in each of the three groups was 30 (n=90). We compared the incidence of vessel twisting and rotation angles across groups. Results: Vessel twisting occurred in 96.7%, 56.7%, and 0% of the cases in the UCS, IS, and RCS groups, respectively. The incidence of vessel twisting differed significantly in all 3 groups (p<0.001), with an apparent trend (p=0.002). The mean rotation angles were 201°±90.6°, 102°±107.6°, and 0° in the UCS, IS, and RCS groups, respectively, which were significantly different (p<0.001). On excluding cases without twisting, the rotation angles of twisted vessels in the UCS and IS groups were 207.9°±83.7° and 180°±77.9°, respectively, which yielded a significant difference between these groups (p<0.001). Conclusions: We found that the incidence and trend of vessel twisting differed significantly across suture techniques. The RCS technique may aid in preventing vessel twisting in the STS bypass procedure.

A Study on Arterial Characterization by using Up-stroke Time of Photoplethysmogram (용적맥파 상승시간에 의한 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.108-116
    • /
    • 2007
  • This paper proposed an analyzable parameter and its analytic method to provide more accurate information than currently employed 4 channels system which uses pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels for the characterization of arterial vessel. In order to verify the volume pulse waves on 4 sites were simultaneously acquired subjects aged from 12 to 81 years old. and the proposed parameters were extracted from time (UT) was then compared with blood pressure. Then, the regression analyses were done relationships among the proposed parameter and others, such as aging, pulse transit time pressure (BP). The followings are the results of linear regression analysis of the proposed parameter for total 50 normal subjects. We selected any two subjects (58 years and 27 years) and measured PPG (photoplethysmogram) and BP of before and after exercise. The coefficient of correlations between BP and UT observed was -0.928 for 50 years subject, and -0.922 for 20 years subject. For total 50 normal subjects, in case of correlation between the pulse transit time and BP, the result showed -0.170 on left side and -0.233 on right side, and the coefficient value of correlation between the pulse transit time and UT was -0.607 on left side and -0.510 on right side. UI is strongly correlated with the pulse transit time than BP. Hence, we believe that the proposed parameter is related with the index of arterial stiffness.

  • PDF

Characteristics and Severity of Side Right-Angle Collisions at Signalized Intersections (신호교차로의 측면직각 층돌사고 특성과 심각도)

  • Park, Jeong-Soon;Park, Gil-Soo;Kim, Tae-Young;Park, Byung-Ho
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.199-211
    • /
    • 2008
  • This study deals with the side right-angle collisions of 4-legged signalized intersections in Cheongju. The goals are to analyze the characteristics of accidents and to find out the accident factors that affect severity using ordered probit model. In pursuing the above, the study uses the data of 580 side right-angle collisions occurred at the 181 intersections(2004-2005). The analyses show that more accidents were occurred in the nighttime and in going straight. The main cause was analyzed to be the red-light violation. Also, the main results of modeling are the following, First, the likelihood ratio index is 0.094 and t-ratio values that explain goodness of fit are significant. Second, minor road traffic volumes, minor road lanes, major road left-turn lanes, major road left-turn signal, major road yellow signal time, cross angle, major and minor road speed limits are significant factors affecting crash severities at signalized intersections.

  • PDF

흉총창에 의한 심방파열 치험 2례

  • Lee, Doo-Yun;Kwack, Sang-Ryong
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.60-65
    • /
    • 1980
  • We have experienced 2 cases of the hunshot wound sof the chest involving cardiac injuries at department of the thoracic surgery, Capital Armed Forces General Hospital during I year from April I 1979 to Jan. 1980. In one case of two patients , he was a 22 years old man who was transported to this emergency room 4 hour 10 minutes after having gunshot wound of the left chest by helicopter. Physical examination showed small inlet in left 3rd ICS and left parasternal border, large outlet in left 8th ICS and left scapular line, no breath sound on left side and distant heart sound. chest roentgenography demonstrated marked pleural effusion in left side and mediastinum shifted to right. As soon as chest X-ray was taken, the bleeding through penetrating wound became profuse and cardiac arrest ensued. Closed chest cardiac massage was started and vigorous transfusion continued, but no effective cardiac activity could not be obtained. The patient was pronounced dead due to exsanguinating hemorrhage from wuwpected cardiac wounds. In this critically injured patient with evidence of intrathoracic hemorrhage and suspected cardiac penetration, only emergency thoracic exploration and immediate surgical control of bleeding points might offer the maximum possibility of survival. The other case was a 23 years old man who was transferred to the emergency room 4 hours 50 minutes after having kmultiple communicated fractures of sternum and linear fracture of right mandible by a missile. Examination revealed about 30% skin loss of the anterior chest wall, weak pulse of 96 beats/min., distant heart sound and decreased breath sounds bilaterally. finding on the chest X-ray films showed multiple sternal fractures, marked pericardial effusion indicating hemopericardium. So, the patient was moved immediately to the operation room where, after endotracheal tube inserted, a median sternotomy was performced. A hemorrhagic congestion of the right upper lobe and marked bulging pericardium were disclosed. The pericardium was opened anterior to right phrenic nerve and exsanguinating hemorrhage ensued from the 0.5cm lacerated wound in the auricle of right atrium. The rupture site of right atrium was occluded with non-crushing vascular clamps and then was over sewn with interrupted sutures. It was thought to be highly possible that he was alive long enough to have cardiorrhaphy because of cardiac tamponade, which prevented exsanguinating hemorrhage. He was taken closed reduction for linear fracture of right mandible 2 weeks after repair of ruptured right auricle in dental clinic. This patient's post-operative course was not eventful.

  • PDF

Inter-observer reliability in cone-beam computed tomography assessment of the retromolar canal: A practical plan to improve diagnostic imaging

  • Igarashi, Chinami;Theramballi, Yeshoda Ganesh;Kobayashi, Kaoru
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Purpose: This study aimed to investigate inter-observer reliability among observers with different levels of proficiency and the diagnostic imaging reliability of cone-beam computed tomography (CBCT) images of the retromolar canal. Materials and Methods: CBCT images of 307 patients were assessed for the presence of retromolar canals(RMCs) by 3 observers independently. Diagnoses were made twice by each observer at intervals of more than 3 weeks. Interobserver reliability was assessed using the kappa coefficient. One observer had no experience in diagnosis using CBCT images. Therefore, a specialist in diagnostic imaging explained the CBCT images for interpretation and practiced diagnostic imaging together with this observer, while the other observer interpreted the images independently. Thereafter, the observers re-evaluated the images. Results: The interobserver kappa coefficients (including bilateral RMCs) calculated at the first reading were low, ranging from 0.21 to 0.61. Their values ranged from 0.95 (right side) to 1.00 (left side) after one-on-one practice with a diagnostic imaging specialist, while the values ranged from 0.65 (right side) to 0.66 (left side) without one-on-one practice. Conclusion: Diagnostic accuracy was improved through diagnostic imaging practice. To improve the anatomical interpretation of images, it is important to practice diagnostic imaging with a specialist in diagnostic imaging. One-on-one instruction about diagnostic imaging was an effective method of training.