• Title/Summary/Keyword: the indoor air pollutant

Search Result 125, Processing Time 0.018 seconds

Source Proximity and Meteorological Effects on Residential Ambient Concentrations of PM2.5, Organic Carbon, Elemental Carbon, and p-PAHs in Houston and Los Angeles, USA

  • Kwon, Jaymin;Weisel, Clifford P.;Morandi, Maria T.;Stock, Thomas H.;Turpin, Barbara
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1349-1368
    • /
    • 2016
  • Concentrations of fine particulate matter ($PM_{2.5}$) and several of its particle constituents measured outside homes in Houston, Texas, and Los Angeles, California, were characterized using multiple regression analysis with proximity to point and mobile sources and meteorological factors as the independent variables. $PM_{2.5}$ mass and the concentrations of organic carbon (OC), elemental carbon (EC), benzo-[a]-pyrene (BaP), perylene (Per), benzo-[g,h,i]-perylene (BghiP), and coronene (Cor) were examined. Negative associations of wind speed with concentrations demonstrated the effect of dilution by high wind speed. Atmospheric stability increase was associated with concentration increase. Petrochemical source proximity was included in the EC model in Houston. Area source proximity was not selected for any of the $PM_{2.5}$ constituents' regression models. When the median values of the meteorological factors were used and the proximity to sources varied, the air concentrations calculated using the models for the eleven $PM_{2.5}$ constituents outside the homes closest to influential highways were 1.5-15.8 fold higher than those outside homes furthest from the highway emission sources. When the median distance to the sources was used in the models, the concentrations of the $PM_{2.5}$ constituents varied 2 to 82 fold, as the meteorological conditions varied over the observed range. We found different relationships between the two urban areas, illustrating the unique nature of urban sources and suggesting that localized sources need to be evaluated carefully to understand their potential contributions to $PM_{2.5}$ mass and its particle constituents concentrations near residences, which influence baseline indoor air concentrations and personal exposures. The results of this study could assist in the appropriate design of monitoring networks for community-level sampling and help improve the accuracy of exposure models linking emission sources with estimated pollutant concentrations at the residential level.

Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

Research on the Actual State of Environmental Disease and Health Education at Middle and High School Students (일 지역 중.고등학생들의 환경성 질환 및 보건교육 실태 조사)

  • Jung, Jong-Hyeon;Moon, Ki-Nai;Seo, Bo-Soon;Kim, Chang-Tae;Lee, Jae-Hong
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.12 no.3
    • /
    • pp.65-87
    • /
    • 2011
  • Objectives: The purpose of this study was to perform basic study on environmental and respiratory diseases in Ulsan and vicinities. Also, this study evaluated the actual state of environmental disease and health education at middle and high schools in Ulsan and surroundings. Methods: For this study, we conducted a survey on the health of the general public, environmental effects, and investigated the characteristics of environmental disease, health and hygiene education, etc. The populations of this study were middle and high school students in Ulsan, Korea. This study investigated the knowledge of environmental disease and health education at schools in Ulsan and vicinities from November 2009 to December 2009. All statistical calculations were performed with Statistical Package for Social Sciences (SPSS) for Windows, and gained the following results by implementing Frequency Analysis, Cross-tabulation Analysis and ANOVA. Results: As more and more environmental diseases are increased, the interest of the people has been increasing on this. The incidence rates of asthma and atopy were represented the top 25% of the country in Korea. The source of heavy metal, PAHs and VOCs in Ulsan includes the Petrochemical Complex at Nam-gu and Ulju-gun, the Nonferrous Metal Industrial Complex at Onsan-eup, Ulju-gun, and the Heavy Industrial Complex at Dong-gu and Buk-gu. Especially, there are a number of fossil fuel combustion facilities such as waste incineration plants and boilers at Nam-gu and the Onsan Industrial Complex. It may help greatly to investigate the characteristics of environmental pollutants such as environmental air pollutant and indoor contaminant to better manage the local student's health. Conclusions: It has been revealed that the hazardous chemicals and environmental contaminants are main substances of cause for asthma, atopy, dermatitis, and allergy disease. Therefore, through with collecting basic data such as environmental disease of inhabitants, health education, conscious and knowledgeable level in parents of students and students, We have to exert to improve knowledge and prevention with health life in school through development of health education program systematically for preventing of environmental disease.

  • PDF

Risk Assessment of Nitrogen Dioxide for Hematological and Biochemical Parameter in Mice (Mice를 이용한 혈액 및 생화학적 특성에 대한 Nitrogen Dioxide의 위해성 평가)

  • Jeong, Seong-Wook;Han, Yong-Soo;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.665-670
    • /
    • 2007
  • In this study, we evaluated the property change and relationship between hematological and biochemical parameters in exposure group and control group by multiple inhalation exposure, of $NO_2$. In case of leukocyte, change of hematological property increased significantly in statistics (p<0.05) in mice experiment. in case of hematocrit of exposure group, it was of decreased significantly in statistics. the tendency of hemoglobin and hematocrit was similar to all for three case. in case of methmoglobin that of the exposure group in mice experiment was meaning increased(p<0.05). For the $NO_2$ influence in biochemical property, total protein and triglyceride was decreased but not significant in statistics, albumin was decreased in the exposure group in the animal experiments, blood urea nitrogen and creatinine increased significantly in statistics in the animal experiments. uric acid and lactate dehydrogenase in serum increased significantly in the exposure group. We have to evaluate risk assessment for the $NO_2$ of indoor air pollutant in low concentration and long time.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.