• Title/Summary/Keyword: the fire prevention design

Search Result 201, Processing Time 0.029 seconds

Analysis on the Implementation Status of Domestic PBD (Performance Based Design) - Focusing on the Fire Scenario and Simulation (국내 성능위주설계의 시행현황 분석 - 화재시나리오 및 시뮬레이션을 중심으로)

  • An, Sung-Ho;Mun, Sun-Yeo;Ryu, Ill-Hyun;Choi, Jun-Ho;Hwang, Cheol-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.32-40
    • /
    • 2017
  • The current status of Performance-Based Design (PBD) implemented in 4 wide areas (Seoul, Gyeonggi, Incheon and Busan) over the past 5 years was reviewed with regard to the number of PBD implementation and target buildings. Then, detailed status related to fire scenarios, input information for fire simulation, and grid size were analyzed with the pre-review for the PBD. As a result, the domestic PBD was mainly applied to the mixed occupancy. In the fire simulations performed on the identical fire scenario and fire space, the maximum heat release rate (HRR) varied significantly depending on the PBD designer. Various combustibles were also considered for the identical fire source, and their combustion properties also showed considerable uncertainty. In addition, the applicability of accurate input information for predictive models of heat and smoke detectors was examined. Finally, the average grid size for the fire simulation using Fire Dynamics Simulator (FDS) was analyzed, and the improvement of PBD to minimize designer dependency was proposed.

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1) (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1))

  • Han, Su-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

A Study on Platform Development of Fire Detector applying IoT (화재감지기에 사물인터넷을 적용한 플랫폼 개발에 관한 연구)

  • Lee, Hae-Keon;Kwak, Dong-Kurl;Lee, Bong-Seob;Jung, Do-Young
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.1-3
    • /
    • 2018
  • When a fire is detected by a sensor of a fire detector, the fire is notified to the manager through the siren. However, if the manager is not indoors, prompt action may not be taken in the event of a fire. In this study, we would like to propose a platform system for fire prevention applying IoT to prevent problems that arise when building manager is absent. This paper presents the structure and operation principle of fire prevention platform system design using IoT, describes the overall system design through fire detector H/W design, micom S/W design and Android application development, and is expected to develop a system that can respond a little faster in case of fire.

  • PDF

Countermeasure against Fire Disaster in Regional Heritage Villages on the Concept of ICT-Based Disaster Prevention Design

  • Park, Sun-Gyu;Mishima, Nobuo;Noh, Hwang-Woo;Yoo, Jae-Soo;Oh, Sang-Hoon;Min, Byung-Won;Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.11 no.1
    • /
    • pp.62-68
    • /
    • 2015
  • Many severe earthquakes have occurred along the main fault lines in the world. In recent years, there has been a high incidence of small- and large-scale earthquakes in our country. These occurrences of earthquakes have become increasingly serious, owing to a degrading earth environment. An earthquake, in general, causes far more serious damages like disruptions in electricity or gas facilities, and fire disasters from its annexed effects than by its vibrations or the shock itself. In this paper, we present a countermeasure and its necessity in safeguarding against fire disasters in regional heritage villages such as "Asan Oeam," "Jeonju Hanok," and "Andong Hahoe." A more systematic and effective strategy for prevention systems against severe fire disasters is proposed after performing various related investigations and analyses of existing domestic and international systems. We investigated the existing fire security systems and their historical records with the tendency of earthquake occurrences in these three folk villages. In this proposal, we present a strategic approach for safeguarding against fire damages in our regional heritage villages derived from ICT (information communication technology)-based DPD (disaster prevention design), after examining the laws and regulations of fire-prevention strategies in Japan, America, and Europe.

Design Proposal for Usability Enlargement of a household Fire Extinguisher (주거용 소화기의 사용성 증대를 위한 디자인 제안)

  • Kang, Byeong-Hwane;Kim, Duek-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.70-79
    • /
    • 2014
  • This paper is on a new design of a household fire extinguisher with an increased initial responsiveness in case of fire. A public survey was taken prior to the new design and 133 faithfully answered surveys among the respondents were used as the research material. The survey was divided into the contents on the recognition of the fire extinguisher, the general requirements and improvement, and it was carried out to be classified on the basis of the results. Design summaries based on the results of surveys conducted are: First, the distance of fire distinguishing material to reach was made to be controlled for more responsiveness in terms of functionality. Second, the head of the fire extinguisher is in red and the spray button is in luminous paint to glow in the dark in terms of visibility. Third, it is made smaller and added a separate handle for bigger sized fire extinguishers in terms of mobility. Fourth, it is made in an aerosol type and has a friendly character on it in terms of approachability. Finally, colors of vivid tones, harmonious pastel tones or light greyish tones were used in terms of aesthetics. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

Simulation of Fire Evacuation Induction System Using Smartphone Navigation Application

  • Shin, Dongmin;Jeon, Seongman;Lee, SungPil;Cho, Byungjun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.243-251
    • /
    • 2020
  • This study is intended to verify the efficiency of the information system by using the navigation application in case of fire. In the demonstration scenario simulation, it was assumed that a fire occurred 6th floor in Korea Institute of Industrial Design Promotion located in C city, K province. Eighty juniors students from K University's department of paramedics of science participated. As a result of the experiment, the demonstration simulation using the navigation application showed that the evacuation time was faster than the case of evacuation guidance in a fire situation. The need for a fire prevention system and fire prevention awareness before and after the implementation of the demonstration scenario simulation increased the need for a fire prevention system and fire prevention awareness score after the experiment.

DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow (천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축)

  • Yoon, Ga-Yeong;Han, Ho-Sik;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.35-42
    • /
    • 2020
  • The accurate prediction of fire detector activation time is required to ensure the reliability of fire modeling during the safety assessment of performance-based fire safety design. The main objective of this study is to determine the activation temperature and the response time index (RTI) of a fixed heat detector, which are the main input factors of a fixed-temperature heat detector applied to the fire dynamics simulator (FDS), a typical fire model. Therefore, a fire detector evaluator, which is a fire detector experimental apparatus, was applied, and 10 types of domestic fixed-temperature heat detectors were selected through a product recognition survey. It was found that there were significant differences in the activation temperature and RTI among the detectors. Additionally, the detector activation time of the FDS with the measured DB can be predicted more accurately. Finally, the DB of the activation temperature and RTI of the fixed-temperature heat detectors with reliability was provided.

The Study on the Legal Improvement for Fire Protection in Wooden Architectural Heritage (목조건축 문화재의 화재방호를 위한 법규 개선에 관한 연구)

  • Kim, Dong Cheol;Roh, Sam Kew;Ham, Eun Gu
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2015
  • This study covers securing legal systems and institutions regarding the standards for installing fire prevention facilities to prevent fire on wooden architectural heritage. Conflicts among relevant laws were revealed and problems related to fire prevention performance, technical standards, responsibilities, etc. in the process of establishing legal fire prevention equipment and the equipment for self-extinguishing were identified through pondering over current legal systems of fire prevention facilities. To resolve the problems, at least the principle to preserve original shapes of wooden architectural heritage should be secured even though fire prevention facilities are installed and the installation process should be regulated by laws considering features of fire on wooden architectural heritage so that fire prevention performance can be guaranteed. The directions to improve installing system through legalization of design, construction, and audit review institutions and legalization of the technical standards for fire prevention facilities were suggested to guarantee performance when establishing fire prevention facilities for wooden architectural heritage.