A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray (진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석)

  • Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

Realization of single supply to reduce power on portable radiation detection device (소모전력 감소를 위한 단일 전원 휴대용 방사선 검출장치 구현)

  • Oh, Jae-Kyun;Nam, Hye-Jin;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.1024-1030
    • /
    • 2015
  • Safety and security system have been internationally enhanced in a field of shipping logistics. Accordingly, techniques for safety and security have been studied steadily. The need of portable radiation detection device is increasing by the search of the container is enhanced. In this paper, we propose a study to improve the life of the system and the realization of portable radiation detection device based on Cortex-A9. Configuration of a portable radiation detection device is configured largely to an analog board and the digital platform and the sensor module. The power used in each stage of the analog board is varied. Uses a switching regulator to use various power supply thereby to generate an error result and cause the switching noise. It is proposed to reduce the power consumption reducing technique for the study.

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF

The establishment of Digital Image Capture System(DICS) using conventional simulator (Conventional simulator를 이용한 Digital image capture system(DICS)의 구축)

  • Oh Taesung;Park Jongil;Byun Youngsik;Shin HyunKyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, flouroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and flouroscopic image. Methods and materials : We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record flouroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) Result : DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Conclusion : Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  • PDF

Entropy analysis in a cilia transport of nanofluid under the influence of magnetic field

  • Abrar, Muhammad N.;Haq, Rizwan Ul;Awais, Muhammad;Rashid, Irfan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1680-1688
    • /
    • 2017
  • In this study, analysis is performed on entropy generation during cilia transport of water based titanium dioxide nanoparticles in the presence of viscous dissipation. Moreover, thermal heat flux is considered at the surface of a channel with ciliated walls. Mathematical formulation is constructed in the form of nonlinear partial differential equations. Making use of suitable variables, the set of partial differential equations is reduced to coupled nonlinear ordinary differential equations. Closed form exact solutions are obtained for velocity, temperature, and pressure gradient. Graphical illustrations for emerging flow parameters, such as Hartmann number (Ha), Brinkmann number (Br), radiation parameter (Rn), and flow rate, have been prepared in order to capture the physical behavior of these parameters. The main goal (i.e., the minimizing of entropy generation) of the second law of thermodynamics can be achieved by decreasing the magnitude of Br, Ha and ${\Lambda}$ parameters.

Examining the qualification of copper magnetic nanocatalyst design and its application in piezoelectric sensor

  • Yufeng Pang;Xiaojuan Li
    • Structural Engineering and Mechanics
    • /
    • v.85 no.6
    • /
    • pp.743-753
    • /
    • 2023
  • Piezoelectricity is defined as the ability of certain materials to produce electric signals when mechanically stressed or to deform when an electrical potential is applied. Piezo technology is becoming increasingly crucial as intelligent devices use vibration sensors to detect vibrations in consumer electronics, the automotive industry, architectural design, and other applications. A wide range of applications is now possible with piezoelectric sensors, such as skin-attachable devices that monitor health and detect diseases. In this article, copper nanoparticles are used in the piezoelectric sensor as the driving agent of the magnetic field. Magnetic nanocatalysts containing copper nanoparticles are used due to their cheapness and availability. Considering that the increase of the electric field acting on the piezoelectric increases the damping (As a result, damping materials reduce radiation noise and increase material transfer losses by altering the natural vibration frequency of the vibrating surface). Among the advantages of this method are depreciating a significant amount of input energy using high energy absorption capacity and controlling slight vibrations in the sensors.

Development of Total Body Irradiation Program (전신방사선조사 프로그램 개발)

  • Choi Byung Ock;Jang Ji Sun;Kang Young Nam;Choi Ihl Bohng;Shin Sung Kyun
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.130-137
    • /
    • 2005
  • In total body irradiation (T81) for leukemia, we have a two methode. One is a AP (anterior-posterior) method and the other is a Lateral methode. Our hospital used lateral methode. T81 must consider about body contour, because of homogeneous dose distribution. For compensation about irregular body contour, we use compensator. For T81 treatment, we must be considered, accurate manufacture of compensator and accurate calculation of dose. We developed the automatic program for T81. This program accomplished for compensator design and dose calculation for irregular body. This program was developed for uses to use in a windows environment using the IDL language. In this program, it use energy data for each energy: TMR, output factor, inverse square law, spoiler, field size factor. This program reduces the error to happen due to the manual. As a development of program, we could decrease the time of treatment plan and care the patient accurately.

  • PDF

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

Error Investigation in use of Near-field Acoustic Holography in the Underwater Environment of Reflected Wave (수중반사파 환경에서의 근접음장 홀로그래피 적용에 대한 오차 고찰)

  • Yi, Jongju;Kang, Myunghwan;Han, Seungjin;Jeong, Hyunjoo;Bae, Sooryong;Jung, Woojin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.12
    • /
    • pp.969-976
    • /
    • 2014
  • Nowadays, it is required for naval ships to estimate 3D underwater radiated noise pattern in all direction at peak frequencies of hull vibration for the reduction of being detected and doing the effective operation. For this purpose, the numerical method has to be developed to calculate 3D underwater radiated noise pattern with experimental data. It is very difficult to obtain the experimental data for the real ship. Alternative to get the experimental results is to use NAH(near-field acoustic holography) in acoustic tank with experimental model. Application of NAH in acoustic tank for the experimental model needs some investigation of reflection wave from the wall of the acoustic tank and unmeasured zone of the experimental model due to the supporting structure for it. In this study, the effect of reflection wave in the acoustic tank and unmeasured area of the experimental model when using the NAH was investigated with experiment and numerical model. From these, it is known for the error due to reflection wave can be reduced when the distance between the measurement plane and source is being shorten. Also, unmeasured area of the experimental model gives rise to some error in the estimation of the far-field acoustic pressure.