• Title/Summary/Keyword: the effect of underground water

Search Result 252, Processing Time 0.032 seconds

A Study on the Analysis of Slope Stability in Consideration of Rainfall Infiltration Effect (강우침투에 따른 사면안정 해석에 관한 연구)

  • Ahn, Jong-Pil;Oh, Hee-Ju;Kim, Jin-Taek;Park, Yong-Hoon;Shim, Tae-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.904-909
    • /
    • 2008
  • Most of current slope safety analysis consider only the effect of the rise of underground water level. However, because the infiltration of surface water into the ground is believed to have signification effect on slope stability, the present study performed slope safety analysis in case of the rise of underground water level, infiltration of surface water, and both resulting from rainfall, and examined their effect.

  • PDF

A Study on the Construction Management in Apartment Housing's Underground Parking Lot for Reduction of Water Leakage (공동주택 지하주차장 누수저감을 위한 시공관리에 관한 연구)

  • Lee, Jae-Hyun;Choi, Il-Ho;Bang, Jung-Seok;Kim, Hyo-Rak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.181-183
    • /
    • 2011
  • This study was carried out about construction management plan to reduce water leakage of underground parking lot in the apartment housing. To minimize effect of upper working load, installation position of jack support and paving with rubble on the top of underground parking lot were studied. By calculation shrinkage strain of underground parking lot scale, water leakage risk in design of level difference was studied. In this study, the basic data about construction management was provided to reduce water leakage of underground parking lot in the apartment housing.

  • PDF

Effect of Underground Dam for the Prevention of Seawater Intrusion at the Seom-jin River (지하댐 설치 시 섬진강 하류 염수침입 방지 효과의 모델기반 분석)

  • Kim, Sungyun;Kim, Gyoobum;Park, Joonhyeong;Shin, Seonho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.8
    • /
    • pp.51-57
    • /
    • 2011
  • Surface water at the lower part of the Seom-jin river has a high salinity because the erosion at river bottom has made sea water move upstream continuously since 1978. The effect of underground dam on the prevention of sea water intrusion was modelled in this study. Present chloride concentration in surface water decreases exponentially along a river and in groundwater is about one-tenth of surface water's. The finite element method model, FEFLOW, was conducted on the assumption that the underground dam with a height of 25m over a bedrock is located under a water surface at the site of 4.6km from an estuary. The result shows that the position with chloride concentration of 0.25psu moves downstream from the sites of 25km to 22km, if an enough sedimentation with 5m thickness happens in the upper reservoir of underground dam. On the other side, the underground dam is little effective for the prevention of sea water intrusion in case of non-sedimentation.

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.

Numerical Analysis of the Effect of Ground Source Heat Pump Systems on the Underground Temperature (지열 시스템의 도입이 지중온도환경에 미치는 영향에 대한 해석적 검토)

  • Nam, Yujin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.427-431
    • /
    • 2013
  • Ground heat pump systems utilize the annually stable underground temperature to supply heat for space heating and cooling. The underground temperature affects not only the underground ecosystem, but also the performance of these systems. However, in spite of the widespread use of these systems, there have been few researches on the effect of the systems on underground temperature. In this research, case studies with numerical simulation have been conducted, in order to estimate the effect of ground heat pump systems on underground temperature. The simulation was coupled with the ground water-ground heat transfer model and the ground surface heat transfer model. In the result, it was found that the underground change depends on the heat transfer from the ground surface, the heat exchange rate, and the heat conductivity of soil.

The effect of blast-induced vibration on the stability of underground water-sealed gas storage caverns

  • Zhou, Yuchun;Wu, Li;Li, Jialong;Yuan, Qing
    • Geosystem Engineering
    • /
    • v.21 no.6
    • /
    • pp.326-334
    • /
    • 2018
  • Underground water-sealed gas storage caverns have become the primary method for strategic storage of LPG. Previous studies of excavation blasting effects on large-scale underground water-sealed gas storage caverns are rare at home and abroad. In this paper, the blasting excavation for underground water-sealed propane storage caverns in Yantai was introduced and field tests of blasting vibration were carried out. Field test data showed that the horizontal radial velocity had a major controlling effect in the blasting vibration and frequencies would not cause the vibration velocity concentration effects. In terms of the influence of blasting vibration on adjacent caverns, the dynamic finite element model in LS-DYNA soft was established, whose reliability was verified by field test data. The numerical results indicated the near-blasting side was primary zone for the structural failure and tensile failure tended to occur in the middle of the curved wall on the near-blasting side. Meanwhile, the safety criterions for adjacent caverns based on stress wave theory and according to statistic relationship between peak effective tensile stress and peak particle velocities were obtained, respectively. Finally, with Safety Regulations for Blasting in China (GB6722-2014) taken into account, a final safety criterion was proposed.

Ground Movement Analysis by Field Measurements (현장계측에 의한 지반거동 분석)

  • Chon, Yong-Back;Cho, Sang-Wan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.3
    • /
    • pp.161-168
    • /
    • 2005
  • This study is analysis for adjacent structures and ground movement by deep excavation work. Underground Inclinometer has shown that deformation of increment is minor within to allowable limit. According to the measurements result of slope and crack for adjacent structures, a detached house showed bigger than hospital structure to deformation of increment. Variation of underground water level didn't effect so much to ground and adjacent structures movement because underground water flows in rock and didn't give the water press to propped walls. Measurement data of strut variation is within tolerance limit. Because excavation site's wall was strengthened suitably. This study will contribute in establishment of measurement standard and information-oriented construction during deep excavation in multi-layered ground including rock masses.

  • PDF

Artificial Groundwater Recharge by Underground piping method (지하매관에 의한 지하수함양 연구)

  • 안상진;이종형
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1990.07a
    • /
    • pp.61-79
    • /
    • 1990
  • The method for artificial groundwater recharge can be categorized into two groups, one is well method and the other one is scattering method. Underground piping method belongs to the latter group and it is to infiltrate water from porous pipes buried underground. This paper shows the result of indoor experiment and numerical analysis concerning this method. The purpose of the study is to make the infiltration aspects and groundwater recharge in underground piping method. We have fround that the recharge height is effect by the difference of water level and a distance of pipe laying.

  • PDF

Artificial Groundwater Recharge by Underground Piping Method (지하관리에 의한 지하수함양 연구)

  • 안상진;이종형
    • Water for future
    • /
    • v.23 no.2
    • /
    • pp.239-250
    • /
    • 1990
  • The method for artificial grondwater recharge can be categorized into two groups, one is well method and the other one is scattering method. Underground piping method belongs to the latter group and it is to infiltrate water from porous pipes buried underground. This paper shows the result of indoor experiment and numerical analysis concerning this method. The purpose of the study is to maky the infiltration aspects and groundwater recharge in underground piping method. We have found that the recharge height is effect by the difference of water level and a distance of pipe laying.

  • PDF

A framework for modelling mechanical behavior of surrounding rocks of underground openings under seismic load

  • Zhang, Yuting;Ding, Xiuli;Huang, Shuling;Pei, Qitao;Wu, Yongjin
    • Earthquakes and Structures
    • /
    • v.13 no.6
    • /
    • pp.519-529
    • /
    • 2017
  • The surrounding rocks of underground openings are natural materials and their mechanical behavior under seismic load is different from traditional man-made materials. This paper proposes a framework to comprehensively model the mechanical behavior of surrounding rocks. Firstly, the effects of seismic load on the surrounding rocks are summarized. Three mechanical effects and the mechanism, including the strengthening effect, the degradation effect, and the relaxation effect, are detailed, respectively. Then, the framework for modelling the mechanical behavior of surrounding rocks are outlined. The strain-dependent characteristics of rocks under seismic load is considered to model the strengthening effect. The damage concept under cyclic load is introduced to model the degradation effect. The quantitative relationship between the damage coefficient and the relaxation zone is established to model the relaxation effect. The major effects caused by seismic load, in this way, are all considered in the proposed framework. Afterwards, an independently developed 3D dynamic FEM analysis code is adopted to include the algorithms and models of the framework. Finally, the proposed framework is illustrated with its application to an underground opening subjected to earthquake impact. The calculation results and post-earthquake survey conclusions are seen to agree well, indicating the effectiveness of the proposed framework. Based on the numerical calculation results, post-earthquake reinforcement measures are suggested.