• Title/Summary/Keyword: the coincidence method

Search Result 157, Processing Time 0.021 seconds

Forest Vegetation of Mt. Baek-Hwa -A Phytosociological Study- (백화산(白華山) 삼림식생(森林植生) -식물사회학적(植物社會學的) 연구(硏究)-)

  • Cho, Hyun Je;Lee, Youn Won;Lee, Dong Sub;Hong, Sung Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.1
    • /
    • pp.42-53
    • /
    • 1991
  • 1. The forest vegetation of the Mt. Baek-Hwa situated in the northwestern Kyungsangpookdo of Korea, on $36^{\circ}16^{\prime}00^{{\prime}{\prime}}{\sim}36^{\circ}19^{\prime}20^{{\prime}{\prime}}N$ and 127 53'20"~127 56'30"E was studied by the method of Zurich-Montpellier School. In the present time, the original vegetation have almost been dominated by substitutional communities such as secondary forests of Pinus, Quercus, Zelkova, Acer or Fraxinus and Pinus rzgida plantations. Some secondary forests developing along the ravine and in northwestern part of slope are, however, maintained in natural condition, and contain some species of the original climax vegetation. They are classified as follows : I. Quercus mongolica-Fraxinus siebol diana community(Mountain forests), I-A. Acer pseudo-sieboldianum -Carex okamotoi group, I-B. Pinus densiflora group, I-B-a. Typical subgroup, I-B-b. Rhododendron schlippenbachii subgroup, II. Fraxinus rhynclzophylla-Acer mono community(Valley Forests), II-A. Acer pseudo-sieboldianum group, II-B. Zelkova serrata group, II-B-a. Typical subgroup, II-B-b. Lindera erythrocarpa subgroup, II-C. Querczrs serrata-Platycarya strobilacea group, II-C-a. Typical subgroup, II-C-b. Lindera erythrocarpa subgroup. 2. Judging from the coincidence method, the structure and distribution of the forest communities was more related to topography than altitude. 3. Considering the actual vegetation, relict species, occurrence of natural seedlings and saplings, climate, successional trends of trees and topographic or edaphic climax conditions, it seems that potential natural vegetation of the area mainly composed of Quercus mongolica, Carpinus laxiflora, Zelkova serrata, Fraxinus rhynchophylla. 4. The flora of the vascular plants collected from this area consists of 108 families, 371 genera, 613 species, 2 subspecies, 88 varieties, 6 forms and 709 taxa in total.

  • PDF

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

The Analysis of Forest Vegetation in Mt. Kumjeong (금정산(金井山) 일대(-帶)의 삼림식생분석(森林植生分析))

  • Yun, Chung Weon;Bae, Kwan Ho;Hong, Sung Cheon
    • Current Research on Agriculture and Life Sciences
    • /
    • v.13
    • /
    • pp.31-44
    • /
    • 1995
  • Mt. Kumjeong is located in south-eastern part of the Korean Peninsular($129^{\circ}$01' to $129^{\circ}$05' E, $35^{\circ}$03' to $35^{\circ}$17' N) and the altitude of the summit is 802 meter. In order to find out the vegetation units which made it possible to classify subtropical forest and south-temperate forest, Mt. Kumjeong (which is located in a border of between subtropical forest and south-temperate forest) was selected as a study area. The primary result of actual vegetation analysis in Mt. Kumjeong based upon the vegetation community analysis methods by the ZM-school, and the relationships between vegetation community and two parameters(altitude, topography) analyzed by using coincidence analysis method were summarized as followings. 1. Based upon analytic methods of the vegetation community by the ZM-schools, the primary analytic result of the analysis of vegetation community in Mt. Kumjeong was divided into 10 communities, 9 groups, 2 subgroups. 2. Eurya japonica group of Pinus densiflora community out of 16 vegetation units was thought as a indicator vegetation group which made it possible to border subtropical forest and south-temperate forest. 3. Natural regeneration of Stewartia koreana group was thought to be difficult because seedling and sapling was rarely showed, 4. In relationship between vegetation units and altitude, Carpinus tschonoskii community, Quercus variabilis community, Quercus serrata community, Wisteria floribunda community,. Eurya japonica group of Pinus densiflora community, Pinus thunbergii community mainly distributed below altitude 500 meter, and Quercus mongolica community, Typical group of Pinus densiflora community, Quercus dentata community, Carpinus coreana community, Quercus acutissima community mainly distributed above altitude 500 meter. 5. In relationship between vegetation units and topography, Carpinus tschonoskii community, Quercus variabilis community, Quercus serrata community, Wisteria floribunda community,. Eurya japonica group of Pinus densiflora community distributed below middle slope, Quercus mongolica community, Typical group of Pinus densifiora community, Quercus dentata community, Carpinus coreana community, Pinus thunbergii community Quercus acutissima communily clistributed above midclle slope.

  • PDF

Relationships between Community Unit and Environment Factor in Forest Vegetation of Mt. Dutasan, Pyeongchang-gun (평창 두타산 산림식생의 군집유형과 입지환경요인의 상관관계)

  • Lee, Jeong Eun;Shin, Jae Kwon;Kim, Dong Gap;Yun, Chung Weon
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.3
    • /
    • pp.275-287
    • /
    • 2017
  • The purpose of this study was to analyze forest vegetation type classification and relationships between the type and environment factor in Mt. Dutasan. Data were collected by total of forty six plots using Z-M phytosociological method from June to October, 2016, and analyzed by vegetation classification, canopy layer structure and relationships between vegetation unit and environment factor using coincidence methods. As a result of vegetation type classification, Quercus mongolica community group was classified at a top level of vegetation hierarchy that was classified into Rhododendron schlippenbachii community and Betula costata community. R. schlippenbachii community was divided into Lychnis cognata group and R. schlippenbachii typical group. L. cognata group was subdivided into Veratrum oxysepalum subgroup and L. cognata typical subgroup. B. costata community was divided into Fraxinus mandshurica group and Betula schmidtii group. F. mandshurica group was subdivided into Weigela subsessilis subgroup and Cimicifuga heracleifolia subgroup. Therefore the forest vegetation was composed of six vegetation units with two kinds of bisected species groups and fourteen species groups. As the result of an analysis of canopy layer structure, there were two kinds of structures with monotonous structures V. oxysepalum subgroup (vegetation units 1), L. cognata typical subgroup (vegetation units 2), W. subsessilis subgroup (vegetation units 4) and complicated structures R. schlippenbachii typical group (vegetation units 3), C. heracleifolia subgroup (vegetation units 5), Betula schmidtii group (vegetation units 6). The vertical layer structure of vegetation unit 5 was the most developed and vegetation unit 6 had the lowest coverage of herb layer. According to the correlation between vegetation unit and environmental factor, R. schlippenbachii community (vegetation units 1~3) and B. costata community (vegetation units 4~6) were classified based on 1,100 m of altitude, middle slope, twenty of slope degree, twenty percents of bare rock and thirty centimeters of DBH in tree layer. R. schlippenbachii community (vegetation units 1~3) showed positive correlation with altitude, topography and B. costata community (vegetation units 4~6) showed negative correlation tendency with them.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.