• Title/Summary/Keyword: the bone mineral density

Search Result 911, Processing Time 0.036 seconds

The Study of Diagnostic Results Discordance Analysis on BMD Using DEXA (이중에너지 X선 흡수 계측법을 이용한 골밀도 검사 시 진단불일치에 대한 분석)

  • Park, Won-Kyu;Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • Purpose : This study was conducted to understand for the diagnostic discordance of bone mineral density(BMD) in DEXA(Dual Energy X-ray Absorptiometry). And the diagnostic difference between lumbar spine and femur neck, forearm was evaluated using T-score. Materials and Methods : We studied 220 females measured BMD on lumbar spine, and femur neck, forearm including ward's triangle and ultra digital(UD). We were distinguished T-score into normal, osteopenia, osteoporosis(WHO classification) and evaluated discordance rate according to age and degree of bone loss. Correlation analysis and chi-square test between L-spine, L-4, femur neck, Ward, Forearm, UD were carried out. Results : In the lumbar spine, the number of normal were in 57(25.9%), osteopenia in 86(39.1%), osteoporosis in 77(35.0%). In the L-4 and ward's triangle, the number of osteoporosis were in 78(35.5%), in 126(57.3%). There was significant correlation between lumbar, femur neck and forearm BMD in all cases. The discordance of BMD between lumbar and femur were 57%, lumbar and forearm 43%, forearm and femur 51%. The discordance rates of normal, osteopenic, osteoporotic groups were 39%, 64%, 43%, respectively, showing the highest discordance rate in osteopenia patients. In normal group of lumbar spine, the discordance rate was 25%, 23%, 11%, 65%, 86% in 30', 40', 50', 60', 70', respectively. In osteopenia, osteoporosis group of lumbar spine, the discordance rate was 62%, 55%, 36%, 20%, 9% in 30', 40', 50', 60', 70', respectively. Conclusion : It was different of the results of BMD with lumbar, femur and forearm site. The discordance rate was decreased with age in osteopenia, osteoporosis lumbar spine. In osteopenia group, the discordance rate was the highest. So, it is necessary that the BMD of lumbar, femur neck and forearm should be checked.

  • PDF

Effect of Types of Egg Shell Calcium Salts and Egg Shell Membrane on Calcium Metabolism in Rats (난각 칼슘염의 종류와 난막의 존재유무가 흰쥐의 칼슘대사에 미치는 영향)

  • Noh, Kyung-Hee;Lee, Sang-Hyun;Ma, Jie;Zhou, Yusi;Kim, Jae-Cherl;Kim, Myo-Jeong;Song, Young-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.7
    • /
    • pp.853-859
    • /
    • 2006
  • This study was carried out to investigate the effect of egg shell calcium salt types and egg shell membrane on calcium metabolism in rats. Sprague-Dawley male rats, 4 weeks of age, were fed on free-calcium diets for 2 weeks after adjustment period. Rats weighing approximately $247{\pm}2.3g$ were divided into 6 groups and were fed on the experimental diets containing 0.2% calcium for 4 weeks. Experimental groups were as follows; {ES(M+)} (egg shell powder diet with egg shell membrane), {ES(M-)} (egg shell powder diet without egg shell membrane), {AC(M+)} (egg shell calcium acetate diet with egg shell membrance), {AC(M-)} (egg shell calcium acetate diet without eg shell membrane), {GC(M+)} (egg shell calcium glucuronate diet with egg shell membrane) and {GC(M-)} (egg shell calcium glucuronate diet without egg shell membrane). Bone length of femur was significantly different by the types (p<0.05) of egg shell calcium salts. Bone mineral density of femur showed the highest level in AC(M-) group. Calcium content of femur and calcium absorption rate were higher in egg shell calcium salt groups than in eg shell powder groups. Calcium absorption rate and retention were significantly different (p<0.05) among the types of eg shell calcium salts and were higher in the AC(M-) group than in the other groups. Alkaline phosphatase activity, parathyroid hormone and osteocalcin levels of serum showed no significant difference among the experimental groups. From the above results, it is concluded that bioavailability of calcium is higher in groups of egg shell calcium salts compared to those in egg shell powder, even though egg shell membrane has no effect on calcium metabolism. Thus, these findings suggest the possibility of using egg shell calcium salts as a functional food material related to calcium metabolism.

A Comparative Study of Influencing BMD Factors in Postpartum and General Women in Their Twenties and Thirties ($20{\sim}30$대 여성의 골밀도 영향 인자에 대한 출산 후 여성과 일반여성과의 비교 연구)

  • Kim, Sun-Geun;Oh, Chan-Ho;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • This study is to evaluate the factors that affect to the bone mineral density(BMD) of postpartum women by comparing BMD between postpartum and general women who are ages from 20 to 39, and to identify correlation between various factors weight, height, body mass index(BMI), hemoglobin(Hb) and BMD. Study subjects were postpartum(n=159) and general(n=180) women. We checked the BMD of femoral neck and lumbar spine by using dual energy X-ray bone densitometry. The mean age was $30.69{\pm}3.32$ in postpartum care group and $31.22{\pm}5.66$ in general women group. In postpartum care group, the mean BMD of femoral neck and lumbar spine were -0.187 and -0.076. In general women group, the mean BMD of femoral neck and lumbar spine were -0.029, and -0.169. According to BMI level, each group was divided into two subgroups. One was 23 or more BMI subgroup, and the other was under 23 BMI subgroup. There was a significant difference in BMD of femoral neck and lumbar spine between two subgroups in general women group, but only a significant difference in BMD of lumbar spine is noted between two subgroups of postpartum group. According to Hb level, each group was divided into two subgroups. One was 11g/dl or more subgroup, and the other was under 11g/dl subgroup. There was not a statistically significant difference of BMD in all subgroups. BMD of femoral neck and lumbar spine showed a significant correlation with weight, height, BMI in both groups. There was a significant correlation between BMD and Hb level in postpartum care group, but a significant correlation was not noted in general women group. The postpartum women showed a significant correlation between BMD and various factors such as weight, height, BMI just like in general women. There was a significant correlation between BMD and Hb in postpartum women, but not in general women.

  • PDF

Genome-wide Association Study Identification of a New Genetic Locus with Susceptibility to Osteoporotic Fracture in the Korean Population

  • Hwang, Joo-Yeon;Lee, Seung-Hun;Go, Min-Jin;Kim, Beom-Jun;Kim, Young-Jin;Kim, Dong-Joon;Oh, Ji-Hee;Koo, Hee-Jo;Cha, My-Jung;Lee, Min-Hye;Yun, Ji-Young;Yoo, Hye-Sook;Kang, Young-Ah;Oh, Ki-Won;Kang, Moo-Il;Son, Ho-Young;Kim, Shin-Yoon;Kim, Ghi-Su;Han, Bok-Ghee;Cho, Yoon-Shin;Koh, Jung-Min;Lee, Jong-Young
    • Genomics & Informatics
    • /
    • v.9 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • Osteoporotic fracture (OF), along with bone mineral density (BMD), is an important diagnostic parameter and a clinical predictive risk factor in the assessment of osteoporosis in the elderly population. However, a genome-wide association study (GWAS) on OF has not yet been clarified sufficiently. To identify OF-associated genetic variants and candidate genes, we conducted a GWAS in a population-based cohort (Korean Association Resource [KARE], n=1,427 [case: 288 and control: 1139]) and performed a de novo replication study in hospital-based individuals (Asan and Catholic Medical Center [ACMC], n=1,082 [case: 272 and control: 810]). In a combined meta-analysis, a newly identified genetic locus in an intergenic region at 10p11.2 (near genes FZD8 and ANKRD30A ) showed the most significant association (odd ratio [OR] = 2.00, 95% confidence interval [CI] = 1.47~2.74, p=$1.27{\times}10^{-6}$) in the same direction. We provide the first evidence for a common genetic variant influencing OF and genetic information for further investigation in bone metabolism.

Studies on the Effects of Antler Extract in Osteoporosis-Induced Rats I. Effects of Antler Extract on Hormones, Ca, P and ALP Levels in Osteoporosis-Induced Rats (녹용 추출물 투여가 골다공증 유발 Rat 에 미치는 효과에 관한 연구 I. 녹용 추출물 투여가 골다공증 유발 Rat 의 혈청내 호르몬, Ca, P, ALP 수준에 미치는 영향)

  • Kim, S. K;Kim, S. W.;Kim, M. S.
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • The present study was carried out in order to investigate the effects of antler extract on hormone concentration, Ca, P and alkaline phosphatase (ALP) levels in ovariectomized rats. Rats were ovariectomized bilaterally and were fed up with Ca- and P-free diet in order to induce osteoporosis. Osteoporosis was determined by the extent of density of bone mineral and lowering the concentrations of serum Ca and P. Male or female antler extract were administrated for 5 weeks to elucidate the protective and therapeutic effects for osteoporosis. The serum concentrations of estradiol, progesterone, calcitonin, osteocalcin, Ca and P, and the activities of ALP of ovariectomized rats were examined for 5 weeks. 1. After administration of female or male antler extract to osteoporosis-induced rats at the doses of 625 mg/kg and 1,250 mg/kg, respectively, the levels of the serum estradiol of the ovariectomized rat significantly decreased from 40.50$\pm$3.34 pg/$m\ell$ to 20.80$\pm$1.86 pg/$m\ell$ for 5 weeks, the levels of serum estradiol were a signigicant lower than those of control group (49.50$\pm$2.70~50.80$\pm$3.l3 pg/$m\ell$). 2. After administration of female or male antler extract to osteoporosis-induced rats at the doses of 625 mg/kg and 1,250 mg/kg, respectively, the levels of serum progesterone were didn't show significant differences. 3. After administration of female or male antler extract to osteoporosis-induced rats at the doses of 625 mg/kg and 1,250 mg/kg, respectively, the levels of serum calcitonin were a little higher than those of control group (0.64$\pm$0.03 ~0.68$\pm$0.04 pg/$m\ell$). 4. After administration of female or male antler extract to osteoporosis-induced rats at the doses of 625 mg/kg and 1,250 mg/kg, respectively, the levels of serum osteocalcin were little higher than those of control groups (0.28$\pm$0.02~0.31$\pm$0.02 ng/$m\ell$). In addition, the levels of serum osteocalcin of female antler extract administered group were little higher than those of male antler extract administered group. 5. The levels of serum Ca and P in osteoporosisinduced rats, administered with male or female antler extract, were little higher than those of control group. However, the levels of serum Ca and P in ovariectomized rats were significantly higher than those of control group (p<0.05). 6. After administration of female or male antler extract to osteoporosis-induced rats, the activities of serum ALP increased compared with those of normal control group. There were significant differences between the serum ALP activities of FA 1,250 and 625 groups (p<0.05). These findings suggest a possible protective and therapeutic effects of female or male antler extract against bone loss in ovariectomized rats, associated with a significant increase of serum estradiol level.

  • PDF

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Prevalence of Osteoporosis among Male Adults with Apparently Radiolucent Lumbar Vertebral Bodies on the Plain Radiographs (단순 영상에서 요추체의 음영이 감소된 성인 남성에서의 골다공증 유병률)

  • Kim, Kook Jong;Lim, Sung Joon;Kim, Yong Min;Lee, Hyung Ki;Kim, Geon Jung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.491-497
    • /
    • 2021
  • Purpose: To investigate the prevalence of osteoporosis or osteopenia via dual-energy X-ray absorptiometry bone mineral density (DEXA BMD) in adult males who showed radiolucent lumbar vertebra on the plain radiographs. Materials and Methods: The DEXA BMD values of 98 adult males, who showed radiolucent vertebrae on plain X-rays, were compared with those of the control group (n=168) and osteoporosis-related fracture group (n=113) by statistical analysis. The World Health Organization (WHO) method (lower value between the mean lumbar and femur neck) and the Hansen's method (lowest lumbar vertebra) were used to determine osteoporosis. Results: The mean and standard deviation of the BMD value of each group was -1.4 (±1.2) in the suspicious group, -0.8 (±1.1) in the control group, and -2.4 (±1.0) in the fracture group, respectively; the difference was statistically significant. Using the WHO method, the prevalence ratio of osteoporosis was 17.3% in the suspicious group, 8.3% in the control group, and 45.1% in the fracture group, respectively. Osteopenia was observed in 40.8% of the suspicious group. Hansen's method (lowest lumbar vertebra) revealed the prevalence of osteoporosis in 30.6% of the suspicious group, 17.9% of the control group, and 62.0% of the fracture group. Conclusion: Approximately 17.3% of the suspicious group was diagnosed with osteoporosis, and 40.8% were osteopenic by a confirmative BMD study (WHO criteria) among the adult males showing apparent radiolucency on plain X-rays. The control group also showed an 8% prevalence of osteoporosis. These results suggest that males also are vulnerable to osteoporosis. Therefore, a BMD study should also be used for males, especially for the people showing lumbar vertebrae with radiolucent features.

Effect of High Calcium Diet on the Zinc and Copper Balance in Korean Female Adolescents (청소년기 여자에서 고칼슘 섭취가 아연과 구리 평형에 미치는 영향)

  • 최보영;남혜경;황용주;김선희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.894-899
    • /
    • 2001
  • Intakes and excretions of zinc and copper were determined for 8 female adolescents (aged 16.4$\pm$0.5 y; body mass index 20.4$\pm$1.3kg/$m^2$; body fat 33.3$\pm$2.5%; bone mineral density of lumbar spine in L2-L4; 0.96$\pm$0.08g/$\textrm{cm}^2$) when they consumed diets basal and high in calcium for 6 days each. All subjects consumed a basal Ca diet containing 800 mg, Korean RDA level of the subjects, and a high Ca diet containing 1200mg, RDA plus 2 SDs of calcium intake. The diets provided 58% of energy intake as carbohydrate, 25% as fat, and 17% as protein. Food, urine and fecal samples were collected during the last 3 days of each feeding period and were assayed. Mean daily intakes on the basal and high calcium diets, respectively, were 6.57 and 6.37 mg for zinc and 910 and 812 $\mu\textrm{g}$for copper. Fecal excretion of copper and zinc in relation to intake was significantly greater on the high calcium than on the basal calcium diet. Hence, apparent absorption rate was significantly lowered from 98.7% on the basal calcium diet to 97.9% on the high calcium diet for zinc from 66.3% to 56.4% for copper, respectively. Urinary loss of copper was not detectable but that of zinc was 0.38mg on the basal diet and 0.47mg on the high calcium diet. Copper retention was 899$\pm$105$\mu\textrm{g}$/day on the basal calcium diet and 792$\pm$20.8$\mu\textrm{g}$/day on the high calcium diet, and zinc retention was 3.95$\pm$0.91mg/day and 3.11$\pm$0.89mg/day. Thus, copper and zinc retention was significantly decreased on the high calcium diet (p<0.05). Summarizing the results, apparent absorption and retention of zinc and copper were significantly decreased by calcium supplementation. Therefore, it is suggested that interactions among minerals should be considered in determining RDA.

  • PDF

The Effect of Distal Hooks in Thoracolumbar Fusion Using a Pedicle Screw in Elderly Patients (척추경 나사못을 이용한 고령 환자의 흉요추부 유합에서 원위부 갈고리의 효과)

  • Lee, Dong-Hyun;Kim, Sung-Soo;Kim, Jung-Hoon;Lim, Dong-Ju;Choi, Byung-Wan;Kim, Jin-Hwan;Kim, Jin-Hyok;Park, Byung-Ook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.83-91
    • /
    • 2017
  • Purpose: To investigate the clinical outcomes of distal hook augmentation using a pedicle screw in thoracolumbar fusion in elderly patients. Materials and Methods: This retrospective multicenter study recruited 20 patients aged 65 years or older, who underwent anterior support and long level posterior fusion in the thoracolumbar junction with a follow-up of one year. To assess the effect of distal hook augmentation, the patients were divided into two groups; the pedicle screw with hook group (PH group, n=10) and the pedicle screw alone group (PA group, n=10). Results: The average age was 72.4 years (65-83 years). The average fusion segment was 4.6 segments (3-6 segments). There were no significant differences in age, sex, causative diseases, bone mineral density of lumbar and proximal femur, number of patients with osteoporosis, and number of fused segments between the two groups (p≥0.05). At 1 year follow-up after surgery, parameters related with distal screw pullout were significantly worse in the PA group. No patients in the PH group had distal screw pullout. However, six patients (60%, 6/10) in the PA group had distal screw pullout. There were no significant differences in the progression of distal junctional kyphosis between the two groups. Conclusion: Distal hook augmentation is an effective procedure in protecting distal pedicle screws against the pullout when long level thoracolumbar fusion was performed in elderly patients aged 65 years or older.