• Title/Summary/Keyword: the amount left

Search Result 492, Processing Time 0.032 seconds

Texture Characteristics of Seokibyung as affected by ingredients (석이병의 재료배합비에 따른 Texture특성)

  • 황미경;이효지
    • Korean journal of food and cookery science
    • /
    • v.9 no.3
    • /
    • pp.198-203
    • /
    • 1993
  • The objective of this study was to evaluate the effect the Seokibyung, when the ingrdients were changed in a variety aspects ; the amount of Seoki flour to rice flour, and several kinds of sweeteners such as sugar, honey and syrup and condition of water. The evaluation of these result were as followings ; 1. According to sensory evaluation, the, flavor, grain, softness, moistness, chewiness, sweetness, overalquality of Seokibyung were the most excellent the mixture of 60g sugar, 280g rice flour, 70g glutious rice flour and 10.5g seoki flour mixed in 90$m\ell$ boiled water. 2. According to Instron evaluation that the higer level resulted to the left to the right treatment that Hardness : syrup, honey, sugar Cohesiveness : honey, syrup, sugar, Adhesiveness : syrup, honey, sugar Gumminess : honey, syrup, sugar Springness : honey, sugar, syrup, Chewiness : honey, syrup, sugar. there was no significant difference among the three treatment groups in each experimental group. 3. The Color & color difference evaluation_that Overall color difference was sugar, honey, syrup in turn. 4. percentages of moisture of honey-added, sugar-added and syrup-added Seokibyung were 42.49%, 41.45% and 36.73% respectively.

  • PDF

The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique (이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구)

  • Ryeom Hun-Kyu;Lee Jongmin;Kim Yong-Sun;Lee Sang-Kwon;Suh Kyung-Jin;Bae Sung-Jin;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Purpose : To investigate the signal enhancement ratio by NOE effect on in vivo $^{31}P$ MRS in human heart muscle and liver. we also evaluated the enhancement ratios of different phosphorus metabolites, which are important in 31P MRS for each organ. Materials and Methods : Ten normal subjects (M:F = 8:2, age range = 24-32 yrs) were included for in vivo $^{31}P$ MRS measurements on a 1.5 T whole-body MRI/MRS system using $^1H-^{31}P$ dual tuned surface coil. Two-dimensional Chemical Shift Imaging (2D CSI) pulse sequence for $^{31}P$ MRS was employed in all $^{31}P$ MRS measurements. First, $^{31}P$ MRS performed without NOE effect and then the same 2D CSI data acquisitions were repeated with NOE effect. After postprocessing the MRS raw data in the time domain, the signal enhancements in percent were estimated from the major metabolites. Results : The calculated NOE enhancement for liver $^{31}P$ MRS were $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%)$ and $PME\;(31\%)$. Because there is no creatine kinase activity in liver, PCr signal is absent. For cardiac $^{31}P$ MRS, whole body coil gave better scout images and thus better localization than surface coil. In $^{31}P$cardiac multi-voxel spectra, DPG signal increased from left to right according to the amount of blood included. The calculated enhancement for cardiac $^{31}P$ MRS were : $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;(PDE)\;(51\%),\;and\;DPG\;(72\%)$. Conclusion : Our results revealed that the NOE effect was more pronounced in heart muscle than in liver with different coupling to 1H spin system and thus different heteronuclear cross-relaxation.

  • PDF

The Comparison of Clinical Study of Off Pump and On Pump CABG (On Pump-CABG와 Off Pump-CABG의 임상적 고찰에 관한 비교연구)

  • 유경종;임상현;송석원;김치영;홍유선;장병철
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.261-266
    • /
    • 2002
  • In an attempt to avoid the adverse effects of the cardiopulmonary bypass, off pump coronary artery bypass grafting(Off pump CABG) that has recently been rediscovered and refined. We compared the preoperative risk factors and in-hospital outcomes of patients done Off pump with those done On pump CABG. Material na Method: One hundred seventy eight patients was underwent CABG between January 2001 and July 2001 12 patients whom underwent associated valvular or left ventricular volume reduction surgery were excluded in this study Data were collected for 52 Off pump CABG and 114 On pump CABG for patient and disease risk factors, extent of coronary disease, and in-hospital outcomes. Result: Off pump CABG and On pump CABG groups did not show any differences in their patient and disease risk factors, and extent of coronary disease. Off pump CABG group had significantly lower mean operation time(234 $\pm$ 37 min vs 290 $\pm$ 48 min, p<0.001), lower mean CK-MB level(10.1 $\pm$ 13.5 IU/L vs 33.1 $\pm$ 18.2 IU/L, p<0.001) and mean ventilation time(14.8 $\pm$ 3.5 hours vs 16.2 $\pm$ 4.9 hours, p=0.048) than On pump CABG groups. On pump CABG group had significantly more distal grafts(3.4 $\pm$ 0.9 vs 2.6 $\pm$ 0.8, p<0.001) than Off pump CABG groups. There were no operative mortality in two groups. Off pump) CABG and On pump CABG groups did not show any differences in their postoperative complications and outcomes including perioperative myocardial infarction, stroke, respiratory failure, renal failure, reoperation, the amount of bleeding, the need of intraaortic balloon pump, the need of inotropics, and the stay of intensive care unit and hospital. Two patients were converted to On pump CABG. Conclusion: This study showed that patients having Off pump CABG are not exposed to a greater risks of adverse outcomes and also provided evidence that patients having Off pump CABG have significantly lower operation time, CK-MB, ventilation time and less distal grafts. Although there may be potential benefits to Off pump CABG, further studies must be directed to determine those patients who would benefit from Off pump CABG.

Surgical Outcome of Patients with Ischemic Cardiomyopathy Selected by the Results of Myocardial Viability by Preoperative F-18 FDG PET (F-18 FDG 양전자단층촬영을 이용한 생존심근 평가 후 수술한 허혈성 심근병증 환자의 수술 결과)

  • Kim, Jae-Sung;Lee, Dong-Soo;Hong, Suk-Keun;Lee, Young-Tak;Kim, Yu-Kyeong;Kim, Youn-Jung;Moon, Keon-Sik;Won, Tae-Kyoung;Hwang, Hweung-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • Purpose: We investigated the operative outcome after bypass surgery in patients selected using viability criteria on F-18 FDG PET. Materials and Methods: Rest-24hr delay redistribution imaging of Tl-201 SPECT and F-18 FDG PET were performed in 11 patients. Seven of these 11 patients (6 men, 1 woman) were evaluated to have viable myocardium by F-18 FDG PET. Changes in symptoms and left ventricular ejection fraction (LVEF) after operation were evaluated. Results: In seven of 11 patients, a significant amount of viable myocardium was found on F-18 FDG PET and Tl-201 SPECT. Severity of both chest pain and dyspnea improved markedly in all patients. Mean LVEF improved from 22% to 32%. Conclusion: F-18 FDG PET could be used to select the patients who will benefit from coronary artery bypass surgery.

  • PDF

A Store Recommendation Procedure in Ubiquitous Market for User Privacy (U-마켓에서의 사용자 정보보호를 위한 매장 추천방법)

  • Kim, Jae-Kyeong;Chae, Kyung-Hee;Gu, Ja-Chul
    • Asia pacific journal of information systems
    • /
    • v.18 no.3
    • /
    • pp.123-145
    • /
    • 2008
  • Recently, as the information communication technology develops, the discussion regarding the ubiquitous environment is occurring in diverse perspectives. Ubiquitous environment is an environment that could transfer data through networks regardless of the physical space, virtual space, time or location. In order to realize the ubiquitous environment, the Pervasive Sensing technology that enables the recognition of users' data without the border between physical and virtual space is required. In addition, the latest and diversified technologies such as Context-Awareness technology are necessary to construct the context around the user by sharing the data accessed through the Pervasive Sensing technology and linkage technology that is to prevent information loss through the wired, wireless networking and database. Especially, Pervasive Sensing technology is taken as an essential technology that enables user oriented services by recognizing the needs of the users even before the users inquire. There are lots of characteristics of ubiquitous environment through the technologies mentioned above such as ubiquity, abundance of data, mutuality, high information density, individualization and customization. Among them, information density directs the accessible amount and quality of the information and it is stored in bulk with ensured quality through Pervasive Sensing technology. Using this, in the companies, the personalized contents(or information) providing became possible for a target customer. Most of all, there are an increasing number of researches with respect to recommender systems that provide what customers need even when the customers do not explicitly ask something for their needs. Recommender systems are well renowned for its affirmative effect that enlarges the selling opportunities and reduces the searching cost of customers since it finds and provides information according to the customers' traits and preference in advance, in a commerce environment. Recommender systems have proved its usability through several methodologies and experiments conducted upon many different fields from the mid-1990s. Most of the researches related with the recommender systems until now take the products or information of internet or mobile context as its object, but there is not enough research concerned with recommending adequate store to customers in a ubiquitous environment. It is possible to track customers' behaviors in a ubiquitous environment, the same way it is implemented in an online market space even when customers are purchasing in an offline marketplace. Unlike existing internet space, in ubiquitous environment, the interest toward the stores is increasing that provides information according to the traffic line of the customers. In other words, the same product can be purchased in several different stores and the preferred store can be different from the customers by personal preference such as traffic line between stores, location, atmosphere, quality, and price. Krulwich(1997) has developed Lifestyle Finder which recommends a product and a store by using the demographical information and purchasing information generated in the internet commerce. Also, Fano(1998) has created a Shopper's Eye which is an information proving system. The information regarding the closest store from the customers' present location is shown when the customer has sent a to-buy list, Sadeh(2003) developed MyCampus that recommends appropriate information and a store in accordance with the schedule saved in a customers' mobile. Moreover, Keegan and O'Hare(2004) came up with EasiShop that provides the suitable tore information including price, after service, and accessibility after analyzing the to-buy list and the current location of customers. However, Krulwich(1997) does not indicate the characteristics of physical space based on the online commerce context and Keegan and O'Hare(2004) only provides information about store related to a product, while Fano(1998) does not fully consider the relationship between the preference toward the stores and the store itself. The most recent research by Sedah(2003), experimented on campus by suggesting recommender systems that reflect situation and preference information besides the characteristics of the physical space. Yet, there is a potential problem since the researches are based on location and preference information of customers which is connected to the invasion of privacy. The primary beginning point of controversy is an invasion of privacy and individual information in a ubiquitous environment according to researches conducted by Al-Muhtadi(2002), Beresford and Stajano(2003), and Ren(2006). Additionally, individuals want to be left anonymous to protect their own personal information, mentioned in Srivastava(2000). Therefore, in this paper, we suggest a methodology to recommend stores in U-market on the basis of ubiquitous environment not using personal information in order to protect individual information and privacy. The main idea behind our suggested methodology is based on Feature Matrices model (FM model, Shahabi and Banaei-Kashani, 2003) that uses clusters of customers' similar transaction data, which is similar to the Collaborative Filtering. However unlike Collaborative Filtering, this methodology overcomes the problems of personal information and privacy since it is not aware of the customer, exactly who they are, The methodology is compared with single trait model(vector model) such as visitor logs, while looking at the actual improvements of the recommendation when the context information is used. It is not easy to find real U-market data, so we experimented with factual data from a real department store with context information. The recommendation procedure of U-market proposed in this paper is divided into four major phases. First phase is collecting and preprocessing data for analysis of shopping patterns of customers. The traits of shopping patterns are expressed as feature matrices of N dimension. On second phase, the similar shopping patterns are grouped into clusters and the representative pattern of each cluster is derived. The distance between shopping patterns is calculated by Projected Pure Euclidean Distance (Shahabi and Banaei-Kashani, 2003). Third phase finds a representative pattern that is similar to a target customer, and at the same time, the shopping information of the customer is traced and saved dynamically. Fourth, the next store is recommended based on the physical distance between stores of representative patterns and the present location of target customer. In this research, we have evaluated the accuracy of recommendation method based on a factual data derived from a department store. There are technological difficulties of tracking on a real-time basis so we extracted purchasing related information and we added on context information on each transaction. As a result, recommendation based on FM model that applies purchasing and context information is more stable and accurate compared to that of vector model. Additionally, we could find more precise recommendation result as more shopping information is accumulated. Realistically, because of the limitation of ubiquitous environment realization, we were not able to reflect on all different kinds of context but more explicit analysis is expected to be attainable in the future after practical system is embodied.

On the wing venation and scales of Dendrolimus spectabilis Butler (I) (솔나방의 시맥(翅脈)과 인편(鱗片)에 관(關)한 연구(硏究) (I))

  • Yun, Jeong Koo
    • Journal of Korean Society of Forest Science
    • /
    • v.2 no.1
    • /
    • pp.59-65
    • /
    • 1962
  • The objects of this experiment are to find out the local variation of the Dendrolimus Spectabilis Butler, of which sample was first collecteted 15 bodies of male and 35 bodies of female adult at Suwon area. the wing veins and the scale shape have been observed through the microscope (100) and the scale size (from the bottom of the scale to the top of the lobe) has also been measured by the micrometer. The results of this experiment are as follows: 1. There is nodifference between the venation of the male body and that of the female body. Also we can not find any differences between the right and the left wing, and between each body. The fore wings consit of 13 longitudinal veins and the only one "V" shape cross vein which is between the 5th and 6th vein. The hind wings consist of 9 longitudinal veins and the only one "V" shape cross vein which is mentioned above. 2. The scale types are divided into 4 Groups in its shape. (A) The scales of I Group are short and the lower parts of them almost look like a circle, having a small projection at their bottom. The upper parts of them have 2 or 10 lobes. We can find the lobes with fine hairs or the lobes without them at the top of the scales. (B) The scales of II Group are longer than that of I Group. The shape of the lower parts of the scales is similar to that of I Group. The upper parts of the scales have 2 or 10 lobes. (C) The scales of III Group are long and almost alike in a long wedgeshape. The upper parts of the scales have 2 Or IO lobes and we can find long fine hairs at the top of each lobe. (D) The scales of IV Group are long and the shape of the lower parts of the scales is similar to that of III Group. The lobes are short and not sharp. We can find 2 or 9 lobes. 3. The scales of I Group and II Group are distributed on the whole surface except on the outer margin. The most scales of III Group are distributed on the wing base. The scales of IV Group are distributed on the outer margin only. The scales with 4 or 5 lobes are most widely distributed not considering their Group or distributing parts. 4. In I Group the variation of the scale length become gradually greater as the number of the lobes are increasing. In II, III, IV Group, however, the variation of the scale length is in direct opposition to the above mentioned. The variation of the scale width becomes pretty small in any Groups and the scale width become wider as the number of the lobes are increasing. 5. The source of the wing colouration is pigmnetal colour, and the wing colouration is expressed by the amount of brown and white scales.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Conservation Status, Construction Type and Stability Considerations for Fortress Wall in Hongjuupseong (Town Wall) of Hongseong, Korea (홍성 홍주읍성 성벽의 보존상태 및 축성유형과 안정성 고찰)

  • Park, Junhyoung;Lee, Chanhee
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.3
    • /
    • pp.4-31
    • /
    • 2018
  • It is difficult to ascertain exactly when the Hongjuupseong (Town Wall) was first constructed, due to it had undergone several times of repair and maintenance works since it was piled up newly in 1415, when the first year of the reign of King Munjong (the 5th King of the Joseon Dynasty). Parts of its walls were demolished during the Japanese occupation, leaving the wall as it is today. Hongseong region is also susceptible to historical earthquakes for geological reasons. There have been records of earthquakes, such as the ones in 1978 and 1979 having magnitudes of 5.0 and 4.0, respectively, which left part of the walls collapsed. Again, in 2010, heavy rainfall destroyed another part of the wall. The fortress walls of the Hongjuupseong comprise various rocks, types of facing, building methods, and filling materials, according to sections. Moreover, the remaining wall parts were reused in repair works, and characteristics of each period are reflected vertically in the wall. Therefore, based on the vertical distribution of the walls, the Hongjuupseong was divided into type I, type II, and type III, according to building types. The walls consist mainly of coarse-grained granites, but, clearly different types of rocks were used for varying types of walls. The bottom of the wall shows a mixed variety of rocks and natural and split stones, whereas the center is made up mostly of coarse-grained granites. For repairs, pink feldspar granites was used, but it was different from the rock variety utilized for Suguji and Joyangmun Gate. Deterioration types to the wall can be categorized into bulging, protrusion of stones, missing stones at the basement, separation of framework, fissure and fragmentation, basement instability, and structural deformation. Manually and light-wave measurements were used to check the amount and direction of behavior of the fortress walls. A manual measurement revealed the sections that were undergoing structural deformation. Compared with the result of the light-wave measurement, the two monitoring methods proved correlational. As a result, the two measuring methods can be used complementarily for the long-term conservation and management of the wall. Additionally, the measurement system must be maintained, managed, and improved for the stability of the Hongjuupseong. The measurement of Nammunji indicated continuing changes in behavior due to collapse and rainfall. It can be greatly presumed that accumulated changes over the long period reached the threshold due to concentrated rainfall and subsequent behavioral irregularities, leading to the walls' collapse. Based on the findings, suggestions of the six grades of management from 0 to 5 have been made, to manage the Hongjuupseong more effectively. The applied suggested grade system of 501.9 m (61.10%) was assessed to grade 1, 29.5 m (3.77%) to grade 2, 10.4 m (1.33%) to grade 3, 241.2 m (30.80%) and grade 4. The sections with grade 4 concentrated around the west of Honghwamun Gate and the east of the battlement, which must be monitored regularly in preparation for a potential emergency. The six-staged management grade system is cyclical, where after performing repair and maintenance works through a comprehensive stability review, the section returned to grade 0. It is necessary to monitor thoroughly and evaluate grades on a regular basis.

A Study of Changes of Pulmonary Artery Size after Bidirectional Cavopulmonary Shunt (양방향성 상대정맥-폐동맥 단락술 후의 폐동맥 크기 변화에 관한 연구)

  • 지현근;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.495-503
    • /
    • 1996
  • The bidirectional cavopulmonary shunt may be useful as an intermediate procedure before Fontal oper- ation in high-risk patients, because it provides adequate relief of cyanosis and relief of ventricular volume overload. But there are no established theory about the effects of bidirectional cavopulmonary shunt on pulmonary arterial development. The purpose of this article is a study of changes of pulmonary artery size after bidirectional cavopulmonary shunt. Ca diac catheterization and angiography procedures were done on 19 patients who underwent bidirectional cavopulmonary shunt from February 1992 to July 1994, their results were reviewed. Preoperative cardiac catheterization and angiography procedures were performed at a mean interval of ).8 $\pm$4.8($\pm$SEM) months before surgery and following catheterization at a mean postoperative interval of 19.6 $\pm$4.8 months. Pulmonary arterial sixte measurement were standardized for body surface area(Pulmon- arty artery index), and for diameter of descending thoracic aorta(McGoon ratio). Patient's age, body stir- face area, pulmonary angioplasty, preoperative McGoon ratio and follow-up intervals were considered as variables. Before bidirectional cavopulmonary shunt, patient's mean age, body surface area, arterial 02 saturation, diameter of right pulmonary artery, diameter of left pulmonary artery, pulmonary artery Index, McGoon ratio were 13.7$\pm$15.6 months, 0.40$\pm$0.12m2, 71.4$\pm$12.4m2, 7.1$\pm$1.7mm, 6.2$\pm$1 , 191.8$\pm$82.7mm21m2, 1.73 $\pm$0.49, respectively. After bidirectional cavopulmonary shunt, the values were changed to 39.9 $\pm$ 16.2 months, 0.58$\pm$0.07 m2, 83.0$\pm$3.8m2, 9.0$\pm$ 1.5 mm, 7.7$\pm$2.0, 197.3$\pm$57.1 mm2/m2, 1.76$\pm$0.32, respect- ively With patients'development (age, body surf'ace area), diameters of pulmonary arteries were increased, but pulmonary artery indices and McGoon ratios were not changed. And there were no effects of age, body surf'ace area, amount of increased 02 saturation, pulmonary angiography and follow-up duration on the increment of pulmonary ar- tery size. But when the McGoon ratio was as low as 1.2, there were significant increase in postoperative pulmonary artery sizes. There was a significant correlation between preoperative pulmonary artery index (PAI) and McGoon ratio (MGR) ; PAI : MGRxl18.0-12.4 In conclusion, bidirectional cavopulmonary shunt provides adequate increment of arterial 02 saturation and does not increase the pulmonary artery size. Further investi ation is mandatory to evaluate the effect of pulsatile bidirectional cavopulmonary shunt on pulmonary artery growth.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF