• Title/Summary/Keyword: thallium 201

Search Result 69, Processing Time 0.034 seconds

A Study on Optimal Myocardium Perfusion SPECT According to Possible Myocardial Infarct Sites (8) 예측성 경색 부위별 최적의 심근관류 단층촬영술 시행에 관한 연구)

  • Song Jae Beom;Lee Wan Kyu;Shu Myung Duk;Jang Sang Sup
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.234-252
    • /
    • 1999
  • Purpose : Physical properties of radiophamaceuticals of technetium($^{99m}Tc$) and thallium($^{201}Tl$) have early been used for clinical diagnostics. The studies of those radiophamaceuticals have been contributed to the efficient to

  • PDF

Protocols of Myocardial Perfusion SPECT (심장관류SPECT 검사 프로토콜)

  • Kim, Seong-Min
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.82-86
    • /
    • 2005
  • In myocardial perfusion scintigraphy, the results of this evalution now confront the practitioner of nuclear medicing with methodologic options. Most nuclear cardiologic studies are performed using thallium-201, Tc-99m sestamibi and Tc-99m tetrofosmin. Some part of these studies use some form of pharmacologic stress test. While tailoring each test to the individual is ideal, this may be impractical for a busy department. Accordingly, established protocols to be used for patients with similar clinical presentations will be helpful. The following review presents methodology of various imaging protocols mainly according to the guidelines of nuclear cardiology procedures in American Society of Nuclear Cardiology.

The Role of Scintimammography in the Diagnosis of Breast Cancer (유방암 진단에서 유방스캔의 역할)

  • Kim, In-Ju
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.213-223
    • /
    • 2001
  • Breast cancer accounts for the higher proportion of cancer related deaths among women, and the incidence of this malignant disease is still increasing. The commonly used screening method is mammography. However, mammography has the drawback of low specificity in differentiating malignant and benign breast diseases. To overcome this low specificity of mammography, scintimammography using various radiopharmaceuticals such as Thallium-201, Tc-99m MIBI, Tc-99m tetrofosmin and Tc-99m MDP was introduced and now actively under the investigation. Several studios have shown that high sensitivity and specificity in detection of primary breast cancer and axillary lymph node metastases using these radiopharmaceuticals. Scintimammography may play important roles in the diagnosis of primary breast cancer, evaluation of the patients with high risk, determining axillary lymph node metastasis, evaluation of the response to chemotherapy, determining the extent of disease, and surveillance of local recurrence. In the future, we should investigate the prognostic role of scintimammography after treatment of breast cancer patients and cost-effectiveness of scintimammography in the detection of primary breast cancer.

  • PDF

The Study on the drug pharmacokinetics according to the progression of liver disease

  • Sohn, Soo-Jung;Choi, Hong-Serck;Ahn, Mee-Ryung;Chung, Hye-Joo;Yoo, Tae-Moo;Lee, Min-Ho;Park, Moon-Seung;Shin, In-Chul;Kim, Ju-ll
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.308.1-308.1
    • /
    • 2003
  • We underwent this study to know correlation between the amount of portosysternic shunt/hepatic fibrosis and bioavailability parameters such as AUC, Cmax, Tmax and t1 /2 of high extraction ratio drug, propranolol, in CCl4-induced liver cirrhosis model of rats. This study describes the bioavaility study of propranolol(5 mg/kg), Shunt Index using thallium-201 per rectum scintigraphy to to measure the amount of portosystemic shunt indirectly and intrahepatic hydroxyproline content performed in the CCl4-induced liver cirrhosis model of rats. (omitted)

  • PDF

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Thallium-201 Perfusion Scan in Peripheral Arterial Disease (말초성 동맥 질환에 있어서 $^{201}T1$을 이용한 말초혈관 관류스캔의 유용성)

  • Nah, Jung-Il;Woo, In-Sook;Kim, Deog-Yoon;Koh, Eun-Mi;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.192-199
    • /
    • 1991
  • Peripheral arterial disease, because of it's significant and prolonged morbidity and related mortality is a major medical and surgical problem. Contrast angiogram remains the essential standard for the anatomic demonstration of disease. It does not, however, provide data suitable for quantification or any evaluation of the microcirculation. For these reasons, radionuclide studies are playing an increasingly important role by not only confirming the diagnosis and offering objective data on the physiologic significance of anatomic lesions, but by offering prognosis of healing and prediction of therapeutic results. In addition, radionuclide procedures offer means to safely and repeatedly monitor response to therapy and long term follow up. The object of this study was to evaluate the clinical availability of $^{201}T1$ perfusion scan in patients with peripheral arterial diseases. We performed $^{201}T1$ perfusion scans in patients with five Buerger' s disease (10 legs), six DM gangrenes (12 legs) and classified three perfusion pattern groups. Finally we compared treatment modalities among each groups and compaired T1-201 perfusion scan findings with angiographic findings in six patients with Buerger's disease. The results were as follows: 1) Seven legs showed increased perfusion in stress image and normal or increased perfusion in resting image (type 1). Six legs showed decreased perfusion in stress image and improved in resting image (type II). Of total 13 legs, only 1 leg needed to amputation. 2) Three legs showed decreased perfusion in stress and resting image (type III), and subsequently all cases were received surgical amputation. 3) In six Buerger's disease patients, there were disagreements in two patients (2 legs) between $^{201}T1$ scan and angiography, in which angiograms were normal but $^{201}T1$ scans showed 'type II' perfusion patterns.

  • PDF

T1-201 Per Rectum Scintigraphy in Chronic Liver Disease: Assessment of T1-201 Uptake Indices (만성 간질환에서의 T1-201 경직장 문맥 신티그라피: T1-201 섭취 지표의 평가)

  • Moon, Won-Jin;Choi, Yun-Young;Cho, Suk-Shin;Lee, Min-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.49-56
    • /
    • 1999
  • Purpose: Heart to liver ratio on T1-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed T1-201 uptake pattern and early liver/heart uptake rate of T1-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Materials and Methods: Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent T1-201 per rectum scintigraphy after instillation of 18.5 MBq of T1-201 into the upper rectum. We evaluated hepatic uptake (type 1 : homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 min) and shunt index (heart to liver uptake ratio). T1-201 uptake pattern and early liver/heart uptake rate of T1-201 was correlated with the pathologic diagnosis and shunt index. Results: Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC. 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH ($0.110{\pm}0.111$) was significantly higher than that of LC ($0.014{\pm}0.090$)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Conclusion: Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on T1-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease.

  • PDF

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

TI-201 Redistribution SPECT and N-13 Ammonia PET Images in Patients with Old Myocardial Infarction and Left Ventricular Dysfunction: Segmental Comparison and Discordance Analysis (좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 TI-201 재분포 SPECT와 휴식기 N-13 Ammonia PET: 분절 비교 및 불일치 분석)

  • Choi, Joon-Young;Lee, Kyung-Han;Kim, Young-Hwan;Lee, Eun-Jeong;Chung, Hyun-Woo;Lee, Su-Jin;Lee, Sang-Hoon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.218-224
    • /
    • 2004
  • We compared rest perfusion PET with redistribution perfusion SPECT to investigate the concordant rate between PET and SPECT images and analyze the discordant pattern. Materials and Methods: Rest N-13 ammonia and F-18 FDG PET were performed on 18 patients with old myocardial infarction and left ventricular dysfunction whose dipyridamole - 4hr redistribution TI-201 SPECT showed one or more severe fixed defects. Regional perfusion and metabolism were evaluated visually and quantitatively with 5-segment myocardial model. Results: There were high concordant rate in uptake pattern (80/90 segments, 88.9%) and high correlation coefficient on quantitative analysis (R=0.81, p<0.001) between redistribution TI-201 SPECT and N-13 ammonia PET images. Nine of 18 patients had SPECT-PET concordant pattern (Group I). Ten segments (9 in inferior wall, 1 in apex) from the remaining 9 patients showed SPECT-PET discordant pattern with abnormal TI-201 defect and near normal N-13 ammonia uptake (Group II). The diastolic and systolic left ventricular dimensions were significantly increased in Group II compared to those of Group I. When attenuation uncorrected N-13 ammonia PET images were reconstructed in Group II, it resulted in PET images with severe inferior wall defects nearly identical to those seen in redistribution TI-201 SPECT images. Conclusion: Redistribution TI-201 SPECT images showed high concordant rate and correlation with rest N-13 ammonia PET images. Most of discordant segments had fixed thallium defects in inferior wall with nearly normal N-13 ammonia uptake, which may result from severe left ventricular dilatation and attenuation by the left hemidiaphragm and cardiac blood pool.