• Title/Summary/Keyword: test strip

Search Result 444, Processing Time 0.035 seconds

Pullout Resistance Characteristics of Strip-type Reinforcement based on Extensibility (신장성에 따른 띠형 보강재의 인발저항 특성)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Kikwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes large scale pullout test results, in order to evaluate extensibility effect of strip-type reinforcement. The same test for ribbed steel strip reinforcement also is conducted to compare the friction resistance reinforcements' evaluation results. The pullout resistance of the ribbed steel strip reinforcement, which has a small cross sectional areas, was better than the friction resistance reinforcements' due to the bearing (passive) resistance. In case of friction resistance reinforcements, the pullout resistance of extensible reinforcement was better than inextensible reinforcement' even though they have a similar cross sectional areas.

Development of Rapid Immune-gold Strip Kit for On-Site Diagnosis of Tomato spotted wilt virus

  • Yoon, Ju-Yeon;Choi, Gug-Seoun;Cho, In-Sook;Choi, Seung-Kook
    • Research in Plant Disease
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • A rapid, user-friendly and simple immune-chromatographic dipstick kit named 'rapid immune-gold strip' (RIGS) kit was developed in a novel single strip format to detect on-site detection of Tomato spotted wilt virus (TSWV). Immunoglobulin G (IgG) from polyclonal antisera raised in rabbits against TSWV was purified through protein-A affinity chromatography and then the purified TSWV-IgG was conjugated to colloidal gold nano-particles which served as a test line on nitrocellulose membrane. Protein A that non-specifically binds to TSWV antibody was used as a control line on the same strip. The diagnosis process with the TSWV-RIGS involves simply grinding the suspect plant sample in a bag that contains the extraction buffer and inserting the strip the bag. Results can be seen in 2-5 minutes. The flow of the complexes of gold particles coated with TSWV-IgG and a crude sap from TSWV-infected pepper, tobacco and tomato plants resulted in intensive color formed on the test lines proportional to the concentrations of TSWV. The RIGS-TSWV kit did not show any cross-reactions against other tomato-infecting viruses unrelated to TSWV. These results indicate that the TSWV-RIGS kit is highly sensitive and is not required for laboratory training and experience prior to testing. The TSWV-RIGS kit is suitable for on-site detection of suspect TSWV-infected plants as well as for laboratory diagnosis.

A Review on Lateral Flow Test Strip for Food Safety

  • Kim, Giyoung;Lim, Jongguk;Mo, Changyeun
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.277-283
    • /
    • 2015
  • Background: Foodborne disease outbreaks from various food sources are a major health concern worldwide. Current methods for detection of foodborne pathogens are both expensive and time-consuming. Purpose: This review aims to present the current information available on the use of lateral flow test strips to detect pathogens in food products to enhance food safety. Results: Frequent foodborne disease outbreaks from various food sources have increased the need for rapid and easy methods for routine analysis of foodborne pathogens. Present detection methods for foodborne pathogens require expensive instruments, experts, and long time for sample analysis. Lateral flow test strips have drawn attention in recent years because of their ability to detect analytes quickly and easily. This review focuses on the principle of the lateral flow test, the various formats of lateral flow test strips, recognition elements, labeling tags, and reading instruments. In addition, this review also discusses the future prospects for the lateral flow test strips.

A Comparative Study on the Shear-Strengthening Effect of RC Beams Strengthened by FRP (FRP로 보강된 RC보의 전단보강효과 비교연구)

  • 심종성;김규선
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.101-111
    • /
    • 1998
  • This study presents test results of RC beams strengthened by carbon fiber sheet(CFS), carbon fiber reinforced plastics(CFRP) or glass fiber reinforced plastics(GFRP) for increasing shear resistance. Nineteen specimens were tested, and the test was performed with different parameters including the type of strengthening materials(CFS, GFRP, CFRP), shear-strengthening methods(wing type, jacket type, strip type), strip-spacing, strengthening direction of FRP. The test results show that shear-damaged RC beams strengthened by FRP(CFS, GFRP, CFRP) have more improved the shear capacity. The mathematical model based on plastic theory was also developed to predict shear strength of shear-damaged RC beams strengthened by FRP. The predictions using the mathematical model. are agreed with the observations from the observed shear strengths for 19 test beams.

Rapid Nutrient Diagnosis of Tomato by Test Strips and a Chlorophyll Meter (Test strip과 chlorophyll meter를 이용한 토마토의 신속한 영양진단)

  • Kim, Kwon-Rae;Jeoung, Han-Ul;Kim, Kye-Hoon
    • Applied Biological Chemistry
    • /
    • v.46 no.2
    • /
    • pp.140-143
    • /
    • 2003
  • This study was performed to develop a more rapid and simple nutrient diagnosis method of plants than the conventional leaf analysis method. tomato (Lycopersicon esculentum Mill. cv. super momotaro) was planted in the mixed media produced by mixing perlite and rock wool at 1 . 1 (v/v) ratio. The Yamazakki nutrient solutions for cucumber and tomato were supplied to the media using the micro-drip irrigation system. Experimental plots produced consisted of no fertilization, deficient fertilization, adequate fertilization and surplus fertilization for N, P and K, respectively. Each experimental plot was replicated four times. Specific color different sensor values (SCDSV) measured by the chlorophyll meter were closely related to total-N concentrations in the leaves measured by the conventional method. Nitrate, $PO_4$ and K concentrations in petiole sap measured by test strips #(Reflectoquant^{\circledR},\;Merck,\;Germany)$ showed a significant relationship with total-N, p and K concentrations in leaves. The linear regression equations between $NO_3,\;PO_4$ and K concentrations in petiole sap and total-N, p and K concentrations in the leaves were prepared. The optimum levels of $NO_3,\;PO_4$ and K in petiole sap were obtained by plugging the optimum concentrations of total-N, p and K in the leaves by other researchers into the equations. In conclusion, the SCDSV by the chlorophyll meter and concentrations of NO3, p and K in petiole sap measured by the test strips would be suitable for rapid estimation of plant nutrient status.

Pullout Resistance by Horizontal Spacing of Geosynthetic Strip (띠형 섬유보강재의 설치간격에 따른 인발저항 특성에 관한 연구)

  • Han, Jung-Geun;Yoon, Won-Il;Hong, Ki-Kwon;Lee, Kwang-Wu;Kim, Ju-Hyong;Cho, Sam-Deok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.315-324
    • /
    • 2010
  • In this study, the pullout tests are conducted to evaluate the pullout resistance of the geosynthetic strip with or without bearing resistance zone. The test results are indicated that the pullout resistance of the geosynthetic strip without bearing resistance zone is not affected by horizontal spacing. However, the horizontal spacing of reinforcement with bearing resistance zone affects the bearing resistance. In other words, it is indicated that the bearing resistance at spacing of 210mm is larger than that at spacing of 260mm. This means that the pullout strength at spacing of 210mm is larger than that at spacing of 260mm. Therefore.

  • PDF

Pullout Resistance of Steel Strip Reinforcement with Transverse Members using Large-scale Pullout Tests (대형인발시험을 이용한 수동지지저항 부재가 설치된 강재스트립 보강재의 인발저항 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • In this study, the large-scale pullout tests are conducted to evaluate pullout resistance of steel strip reinforcement with transverse members. The test results clearly showed the passive effect by normal stress. This suggests that both friction resistance and passive resistance by normal stress should be taken into account in the evaluation of pullout resistance for design. Therefore, The evaluation results confirmed that the developed steel strip reinforcement with transverse members depend heavily on passive resistance by normal stress.

  • PDF

Development of New Back-Up Roll for Strip Shape Control (형상제어를 위한 새로운 보강롤의 개발)

  • Lee, Won-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.327-333
    • /
    • 2003
  • Most of shape defects in steel strip are originated from the structure of rolling mill itself. For instance, strip crown occurs when the work roll is deformed by the bending moment induced on roll chocks. To get rids of the shape defects, it is necessary to increase the stiffness of rolling mill. The structure change of back-up roll is one of alternative ways to increase the mill stiffness without facility revamping from 4 high mill to 6 high mill. In this research work, the new back-up roll was developed and can be used in any type of 4 high mill to reduce the strip shape defects. The developed back-up roll consists of sleeve, arbor and phase angle adjusting system for arbor. The circumference of arbor is specially machined to adapt the strip width change during rolling. The experimental cold rolling test was done to prove the effectiveness of newly developed back-up roll. The experimental rolling results show that the new back-up roll has more powerful performance in reducing the shape defects than conventional back-up roll. It was also found that the new back-up roll has higher stability for shape control. In addition to, the only sleeve surface needs to be reground and changed in most cases, so that the maintenance cost can be greatly reduced.

CLINICAL AND MICROBIOLOGICAL EFFECT OF MINOCYCLINE-LOADED POLYCAPROLACTONE FILM ON RAPIDLY PROGRESSIVE PERIODONTITIS (급속진행형 치주염에서 Minocycline을 함유한 Polycaprolactone film의 임상 및 미생물학적 효과에 관한 연구)

  • Choi, Hyun-Soon;Um, Heung-Sik;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.421-432
    • /
    • 1994
  • The local route of antibiotic administration can accomplish higher therapeutic doses in subgingival sites than those possible by systemic therapy. This investigation assessed on the clinical and microbiological effect of 30% Minocycline loaded polycaprolactone film (Mino-strip) on rapidly progressive periodontitis. Mino-strip was applied in the periodontal pockets of 15 patients with clinically diagnosed as a rapidly progressive periodontitis. 8sites for each patient with a 5mm probing pocket depth were selected in split mouth design and were assigned into group. i.e., placebo(group 1), supragingival scaling and R/P(group 2), Mino-strip applied only(group 3), R/P and Mino-strip applied(group 4). Supragingival scaling and oral hygiene instruction were performed 1 wk before experiment. Mino-strip was applied weekly on day 0 and 7. Clinical and microbiological test were performed on day 0, 7, 14, 28, 56. In R/P and Mino-strip applied group, Gingival index, GCF volume, probing depth and loss of attachment level were significantly reduced after the first weeks following treatment. In R/P and Mino-strip applied group, the relative proportions of spirochetes and motile rods were significantly reduced and the proportions of cocci and non motile rod were correspondingly increased for eight weeks following treatment. In R/P and Mino-strip treated group, total anaerobic and aerobic bacterial count were significantly decreased for the first two weeks following treatment and streptococcus count was decreased for eight weeks following treatment. In R/P and Mino-strip applied group, P. gingivalis, P. intermedius, B. forsythus, A. actinomycetemcomitans, F. nucleatum, E. corrodens, C. rectus counts were significantly reduced after the first week following treatment. According to this study, it is appeared that 30% Minocycline-loaded polycaprolacton film was effective in the treatment on rapidly progressive periodontitis.

  • PDF

Effects of Alloying Elements and Heat Treatments on the Microstructures and Mechanical Properties of Ductile Cast Iron by Strip Casting (스트립캐스팅한 구상흑연주철박판의 합금원소 및 열처리에 따른 미세조직과 기계적 성질의 변화)

  • Lee, Gi-Rak;Ra, Hyung-Yong
    • Journal of Korea Foundry Society
    • /
    • v.20 no.2
    • /
    • pp.122-128
    • /
    • 2000
  • Strip casting process is a new technology that makes a near net shape thin strip directly from molten metal. With this process, a large amount of energy and casting cost could be decreased from the abbreviation of reheating and/or hot rolling process. Ductile cast iron which has spheroidal graphite in the matrix is the most commercial and industrial material, because of its supreme strength, toughness, and wear resistance etc. But it cannot be produced to the thin strip owing to difficulty in rolling of ductile cast iron. In this study, ductile cast iron strips are produced by the twin roll strip caster, with different chemical compositions of C, Si, and Mn contents. And then heat-treated, microstructures and mechanical properties are examined. The microstructures of as-cast strip are that of white cast iron which consists of the mixture of cementite and pearlite, but the equiaxed crystal zone of the pearlite or segregation zone of cementite exists in the center region of the strip thickness, which cannot be observed in the rapidly solidified metallic mold cast specimens. This structure is supposed to be formed from the thermal distribution of strip and the rolling force. Comparing with the structures of each strips after heat treatment, increasing Si content makes smaller spheroidal graphite and more compact in the matrix, furthermore the less of Mn content makes the ferrite matrix be obtained clearer and easier. As a result of the tensile test of graphitization heat-treated strips, the yield strengths are about 250 MPa, the tensile strengths are about $430{\sim}500$ MPa, and the elongations are about $10{\sim}13%$. In the case of the strip which has the smaller and more compact spheroidal graphite in the ferrite matrix, the higher tensile strength and better drawability could be obtained.

  • PDF