• 제목/요약/키워드: test procedures

검색결과 1,841건 처리시간 0.031초

골연하 결손부에서 조직유도재생술의 장기적 방사선학적 변화 관찰 (Long-term radiographic evaluation of GTR treatment in intrabony defect)

  • 최미혜;박진우;서조영;이재목
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.181-192
    • /
    • 2007
  • Periodontal surgery as part of the treatment of periodontal disease is mainly performed 1) to gain access to diseased areas for adequate cleaning; 2) to achieve pocket reduction or elimination; and 3) to restore the periodontal tissues lost through the disease; i.e., a new attachment formation of periodontal regeneration. To accomplish the latter, often referred to as the ultimate goal of periodontal therapy, a number of surgical procedures have been advocated throughout the years. Clinical studies have demonstrated that considerable gain of clinical attachment and bone can be achieved following guided tissue regeneration (GTR) therapy of intrabony defects. The aim of this study was to analyse the radiographic bone changes 2-year after GTR using a bone graft material and nonresorbable membrane. Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of intrabony defect(s), 33 sites of 30 patients aged 32 to 56 (mean age 45.6) were treated by GTR with a bone graft material and nonresorbable membrane. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. We observed $2.86{\pm}1,87mm$ of bone fill, $065{\pm}0.79mm$ of crestal resorption, $3.49{\pm}2.11mm$ of defect resolution, and $44.42{\pm}19.51%$ of percentage of defect resolution. Mandible, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. But no difference was observed between xenograft and allograft. Outcome of GTR as a therapy of intrabony defect was better than other therapy, but herein, good oral hygiene maintenance as a anti-infective treatment and periodic recall check of patients are essential.

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

  • Lee, Jungwon;Pyo, Se-Wook;Cho, Hyun-Jae;An, Jung-Sub;Lee, Jae-Hyun;Koo, Ki-Tae;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • 제50권1호
    • /
    • pp.56-66
    • /
    • 2020
  • Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

건축용 압출법 단열판(XPS)의 자기소화성에 대한 실험적 연구 및 제도적 관리에 관한 제언 (Experimental Study on the Self-extinguishing Performance of Extruded Polystyrene Insulation for Buildings and Suggestions on Institutional Management)

  • 강정기;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.141-149
    • /
    • 2020
  • 한국산업표준(KS)은 발포 플라스틱 제품에 대하여 소형화염에 의한 수평 연소성의 측정 방법 및 시험절차를 규정(KS M ISO 9772:2018)하고 측정 결과에 대한 압출법 단열판(이하 XPS)의 자기소화성과 관련한 성능 및 기준을 KS 규격(KS M 3808:2020)에서 규정하고 있다. KS 규격에 적합함을 인증 받은 제품은 연소성(이하 '자기소화성')을 가지고 있어야 함에도 공사현장에서 용접불티 등에 의해 착화 및 확산되어 대량의 인명과 재산 피해가 발생하고 있는 실정이다. 본 연구에서는 KS 인증을 받고 시중에 판매 중인 5개사의 XPS 단열재를 구입하여 공사현장에서 발생되는 용접불티에 의한 착화 및 확산 여부를 실험하였다. 실험결과, 5개사의 제품 중 3개사는 성능의 차이는 있으나 자기소화성이 있는 것으로 확인되었으나, 2개사는 쉽게 착화 및 확산되어 자기소화성이 있다고 보기 어려웠다. 동종의 제품에 대하여 KS 규정에 따른 실험결과, 용접불티에 의해 착화되었던 제품 2종을 포함한 총 3종의 제품이 KS M 3808에서 규정한 자기소화성이 없는 것으로 확인되었다.

RFID/USN 연동 시스템을 활용한 건설자원 실시간 모니터링 시스템 (Real-Time Construction Resource Monitoring using RFID/USN Inter-working System)

  • 류정필;김형관;김창윤;김창완;한승헌;김문겸
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2007년도 정기학술발표대회 논문집
    • /
    • pp.90-94
    • /
    • 2007
  • 건설 현장의 자재 위치 추적 기술은 건설 프로젝트의 생산성을 극대화시킬 수 있는 중요한 기술로서 현재 국내외적으로 많은 연구가 수행 중에 있다. 최근 들어 RFID(Radio Frequency Identification) 시스템을 이용하여 공급 사슬망 전반에 걸친 건설 자재에 대한 실시간 위치 추적에 대한 연구가 각광을 받고 있다. 그러나 짧은 인식거리, 저조한 인식율등의 문제로 바코드 대체 수준으로 그 활용이 미비한 상황이다. 본 논문에서는 인식거리르 보다 길게 하는 900MHz 대역의 RFID 시스템과 인식된 데이터를 무선 통신(Zigbee)을 사용하여 전달하는 RFID/USN 연동시스템 개발과 그 활용 방안을 제안한다. RFID/USN 연동 시스템을 건설현장의 자재관리에 시험적으로 적용, 실중 테스트를 수행함으로써 첨단 센싱 기술 및 전파식별 기술에 대한 현장 활용 가능 여부, 실증 테스트 시 발생하는 기술적 애로 사항 및 다양한 활용 방안을 도출하는 것을 목적으로 한다. 또한 원격지에 있는 현장 관리자를 위하여 기존 인프라네트워크를 이용하여 실시간 자재 및 장비의 위치 데이터를 관리자가 원할 경우 언제 어디서든 실시간으로 전달 가능하도록 이동통신망(CDMA: Code Division Multiple Access)과의 연동 시스템을 현장에서 적용 및 점검한다.

  • PDF

유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가 (Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation)

  • 심수영;유호석;김한별;정재훈;이상준;김성민;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

H.323 트래픽 분석 시스템의 개발 (Implementation of Analysis System for H.323 Traffic)

  • 이선헌;정광수
    • 정보처리학회논문지C
    • /
    • 제13C권4호
    • /
    • pp.471-480
    • /
    • 2006
  • 최근 다양한 네트워크 환경이 고속으로 발전하면서 화상회의나 VoIP와 같은 고품질의 서비스들이 빠르게 보편화 되어 가고 있다. 오디오, 비디오와 같은 멀티미디어 화상회의 데이터를 인터넷을 통해 전송하기 위한 국제표준인, H.323은 가장 많이 개발되어 상용화된 프로토콜로 다양한 환경을 지원하면서도 성능이 뛰어난 것으로 인식되고 있다. 이러한 환경에서 사용자에게 제공하는 H.323 기반 서비스에 문제가 생기게 될 경우, H.323 을 구성하는 프로토콜들의 문제인지, 네트워크 자체의 문제인지를 제대로 분석하는 것이 매우 중요한 기술적 이슈로 대두되고 있다. 이러한 정확한 원인 분석은 H.323 기반의 서비스를 제공하는 네트워크 운영자뿐만 아니라 종단간의 사용자에게도 매우 중요한 서비스 품질의 판단 기준이 되며, 향후 H.323 기반 서비스의 유지 보수에도 많은 도움이 될 것으로 기대할 수 있다. 본 논문은 다양한 네트워크 환경에서의 H.323 기반의 영상 서비스를 가정할 때, H.323 프로토콜의 주요 하위 표준들인 H.245, H.225.0, RTP, RTCP등의 프로토콜을 정확히 분석할 수 있는 통합 분석 시스템인 H.323 Sniffer 개발을 목적으로 한다. 간단한 기능 실험과 성능 분석을 통해 본 논문에서 제안하고, 구현한 분석 시스템이 실제 네트워크 환경에서 서비스되는 H.323 기반 서비스의 상태를 성공적으로 분석하고 이를 통해 발생가능한 문제점의 원인을 판단할 수 있음을 검증하였다.

레진 인레이 합착시 지각과민처리제의 사용이 상아질 결합강도에 미치는 영향 (EFFECT OF A DESENSITIZER ON DENTINAL BOND STRENGTH IN CEMENTATION OF COMPOSITE RESIN INLAY)

  • 한세희;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제34권3호
    • /
    • pp.223-231
    • /
    • 2009
  • 본 연구는 인레이 와동에서 인상을 채득하기 전 지각과민처리제 (Isodan)과 2단계 전부식 접착시스템 (One-Step)과 단일단계 자가부식 접착시스템 (All-Bond SE)으로 처리한 후, 복합레진 인레이를 자가 접착형 레진시멘트인 BisCem으로 합착시키는 경우 레진 인레이의 상아질에 대한 미세인장결합강도와 주사현미경적인 분석을 통하여 비교하였다. 본 연구의 결과, 지각과민처리제인 Isodan만을 사용하는 경우 레진 인레이의 결합강도를 감소시킬 수 있으므로 단독 사용보다는 단일 단계 자가부식 시스템 (All-Bond SE)과 같이 사용하는 것이 추천된다.

이동통신 네트워크 트래픽 모델을 위한 도시 지역 이동통신 트래픽 특성 분석 (Analysis of Network Traffic with Urban Area Characteristics for Mobile Network Traffic Model)

  • 윤영현
    • 정보처리학회논문지C
    • /
    • 제10C권4호
    • /
    • pp.471-478
    • /
    • 2003
  • 오래 전부터 이동통신 서비스를 위한 통신 프로토콜이나 기능 요소들의 성능을 평가하기 위해서는 분석적 방법, 시뮬레이션 및 평가적 방법이 이용되어 왔다. 이중 시뮬레이션을 통한 평가 방법은 시스템 내부 구성 요소들의 연관 관계가 매우 복잡한 시스템을 테스트하는데 유용하게 사용되고 있으며, 이를 위해서는 이동통신 통화 특성을 반영하는 텔레트래픽 모델을 제시하고 있어야 한다. 텔레트래픽 모델은 일반적으로 트래픽 소스 모델과 네트워크 트랙픽 모델로 구성되어 있으며, 본 네트워크 트래픽 모델을 정의하기 위해 요구되는 실제 기지국 통화량 자료를 수집하고 분석한 결과를 제공하기 위한 것이다. 본 논문에서는 서울시를 상업, 주거, 준공업, 그리고 녹지 지역으로 되어 있는 도시계획 용도지역으로 구분하고, 여기에 설치되어 있는 기지국으로부터 실제 데이터를 시간대별로 수집하였다. 수집된 자료를 이용하여 각 지역별 기지국의 시간대별 통화량 분포와 최대 및 최소 발생 호 수 등을 제시하였다. 분석 결과는 보다 더 정확한 이동통신 네트워크 트래픽 모델을 정의하거나, 기존 이동통신 시뮬레이션 과정에서의 입력 자료로 사용할 수 있다.

국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구 (The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards)

  • 하태성;안철;정평환;조정희;이종석;이혜남;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.387-394
    • /
    • 2010
  • 보건의료 분야에서 방사선은 의료기기 등의 멸균을 목적으로 빠르게 기존 방법을 대체하고 있으며 국제적으로, 정립된 엄격한 품질기준을 적용하고 있다. 방사선 멸균의 품질관리는 조사된 제품의 흡수선량이 요구 조건 및 기준에 부합하고 있음을 보증하는 것인데, $Co^{60}$ 동위원소를 이용하는 감마선 조사와는 달리 기계 전기적 방법에 따른 전자빔 조사는 더욱 많은 공정인자에 대해 기술적인 접근 방법이 필요하다. 국내에서는 2000년대 초반부터 전자빔 가속기의 보급이 시작되어 연구 및 산업분야에 이용되고 있으나 국제적 품질체계에 부합한 흡수선량의 품질에 관련된 연구는 매우 미흡한 실정이다. 서울방사선서비스는 2008년 10 MeV, 8 kW 사양의 대단위 전자빔 조사시설을 설치, 운영하기 시작하였는데, 전자빔 가속기, 제품운송장치, 안전장치, 기록관리 및 하위 구성장치가 통합시스템을 구성하여 우수제조기준에서 요구하는 공정품질 및 제품추적이 가능하도록 설계되었다. EN ISO11137로 대표되는 국제 표준의 이행을 위해서는 표준이 의도하는 바를 정확히 이해하고 장치의 설계기준부터 운영단계 별로 요구되는 품질시험을 정해진 절차 및 기준에 부합하도록 수행하여야 한다. 본 연구에 사용된 조사시설의 설계 시방을 제시하고 이를 구현하는데 필요한 핵심 장치의 설계 기준 및 특징에 대해 소개하였다. 또한 흡수선량 품질보증이라는 목적을 달성하기 위해 다양한 공정인자에 대한 품질시험결과를 제시하고 제시된 기준과 비교, 평가하였다.

Immediate breast reconstruction following nipple-sparing mastectomy in an Asian population: Aesthetic outcomes and mitigating nipple-areolar complex necrosis

  • Pek, Wan-Sze;Tan, Bien-Keem;Ng, Yvonne Ying Ru;Tan, Veronique Kiak Mien;Rasheed, Mohamed Zulfikar;Tan, Benita Kiat Tee;Ong, Kong Wee;Ong, Yee Siang
    • Archives of Plastic Surgery
    • /
    • 제45권3호
    • /
    • pp.229-238
    • /
    • 2018
  • Background Nipple-sparing mastectomies (NSMs) are increasingly performed to obtain the best aesthetic and psychological outcomes in breast cancer treatment. However, merely preserving the nipple-areolar complex (NAC) does not guarantee a good outcome. Darkly pigmented NACs and a tendency for poor scarring outcomes are particular challenges when treating Asian patients. Herein, we review the reconstructive outcomes following NSM at Singapore General Hospital. Methods All breasts reconstructed following NSM over an 11-year period from 2005 to 2015 were reviewed. Information was collected from the patients' records on mastectomy indications, operative details, and complications. Patient satisfaction, breast sensation, and aesthetic outcomes were evaluated in 15 patients. Sensation was quantified using the Semmes-Weinstein monofilament test. Results A total of 142 NSMs were performed in 133 patients for breast cancer (n=122, 85.9%) or risk reduction (n=20, 14.1%). Of the procedures, 114 (80.2%) were autologous reconstructions, while 27 (19.0%) were reconstructions with implants. Complications occurred in 28 breasts (19.7%), with the most common complication being NAC necrosis, which occurred in 17 breasts (12.0%). Four breasts (2.8%) had total NAC necrosis. The overall mean patient satisfaction score was 3.0 (good). The sensation scores were significantly diminished in the skin envelope, areola, and nipple of breasts that had undergone NSM compared to non-operated breasts (P<0.05). Half of the subset of 15 patients in whom aesthetic outcomes were evaluated had reduced nipple projection. Conclusions Immediate reconstruction after NSM was performed with a low complication rate in this series, predominantly through autologous reconstruction. Patients should be informed of potential drawbacks, including NAC necrosis, reduced nipple projection, and diminished sensation.