• Title/Summary/Keyword: test methods

Search Result 27,418, Processing Time 0.071 seconds

Aircraft Lightning Test Methods (항공기 낙뢰시험)

  • Choi, I.S.;Kim, S.S.;Han, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1790-1792
    • /
    • 2004
  • This paper deals with the lightning test methods on aircraft. It shows lightning current and voltage test waveforms referred to SAE ARP 5412. According to this standard, to test lightning effects, mixes appropriately 5 waves for current and 4 waves for voltage depend on structure and comparison information.

  • PDF

Relationship of Test Methods of Impact Absorbing Effect of Floors from a viewpoint of Safety in Accidental Collisions (인체충돌시 바닥의 안전성에 관한 시험방법간 연관성 분석)

  • Kim, Sang-Heon;Ji, Suk-Won;Yoon, Jung-Sik;Choi, Soo-Kyug;Seo, Chee-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • Since the study of building performance design was first undertaken by Building Research Station in 1930s, the results of such study has been reported from many parts of the world, building construction codes and standards have been revised based on performance in advanced nations as well in Korea, and various performance certification systems are in operation. The purpose of this study is to build a database of performance certification systems to investigate the co-relationship of various test methods related to the same test items. As test methods for case study, we selected test methods involving collision of the human body. Through analysis of Critical fall height test of EN 1177 and Head Model test of JIS A 6519 about 8 species of floor test-bodies, it was found that there are limits of application in terms of the depth and strength of cushion. Furthermore, although the measured physical parameters are the same, when the co-relationship between test methods is uncertain, the various physical parameters may not be compatible with the results.

Fundamentals of Ecotoxicity Evaluation Methods using Domestic Aquatic Organisms in Korea : (I) Fish (국내 생물종을 이용한 생태독성평가 기반연구 : (I) 어류)

  • Nam, Sun-Hwa;Yang, Chang-Yong;An, Youn-Joo;Lee, Jae-Kwan
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.173-183
    • /
    • 2007
  • The Ministry of Environment plans to introduce the Whole Effluent Toxicity (WET) system in Korea. The WET test is well established in developed countries with recognizing of the limitations of physicochemical analysis method and potential risk of chemicals in water medium. Therefore, it is essential to build the ecotoxicity infrastructure for the induction of WET test. In this study, we extensively collected the domestic and foreign toxicity test methods which employ native test species to Korea. And we suggested that the domestic ecotoxicity test methods with domestic test species in Korea through extracting the range of test conditions. Five domestic fish species selected were Carassiu auratus (Crucian carp), Cyprinus carpio(Common carp), Gasterosteus aculeatus (Three spine stickleback), Misgurnus anguillicaudatus (Oriental weather fish) and Oryzias latipes (Japanese medaka), The toxicity test methods with native test species to Korea were collected from the standard methods (OECD, U.S. EPA, ASTM), government reports, SCI papers and domestic papers. We collected the 32 test methods, and suggested the suitable aquatic toxicity test methods for fish. It is expected that this study could prove a useful information to establish the ecotoxicity test methods with domestic aquatic organisms in Korea henceforth.

The Analysis of Factors Affecting Test and Evaluation in Domestic Purchase Program (국내 구매사업 시험평가에 미치는 영향요인 분석)

  • Park, Jong Wan
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.222-232
    • /
    • 2015
  • Purpose : The purpose of this study is to analyse affecting factors of Test and Evaluation and to improve the institution of Test and Evaluation in the Domestic purchase program. Methods : The domestic acquisition program is currently small in terms of size, but it is gradually increasing every year. Still, the domestic purchase program has insufficient regulations and procedures compared to the other procurement methods including research & development. Various problems are likely to occur between test and evaluation group, and defense industries regarding the regulations during Test & Evaluation. Therefore, the regulations and methods need to be amended to upgrade the current domestic purchase program into an effective and flawless one. In this paper, six variables have been chosen by the help of experts working in Ministry of National Defense (MND), Joint Chiefs of Staff (JCS), Army Headquarters and DAPA. Results : The six variables are effectiveness of proposal evaluation, fairness of test and evaluation, sufficiency of operational capabilities, seasonal period of test and evaluation, fulfillment in Integrated Logistics Support (ILS) of the industries, and guaranteeing appropriate environment for related enterprises' participation. Conclusion : This paper can help defense industries to enhance their development capabilities, and to perform tests more fairly and effectively considering the key factors identified in this research.

Accelerated Tensile Creep Test Method of Geosynthetics for Soil Reinforcement (보강용 지오신세틱스의 가속 인장 크리프 시험방법)

  • Koo, Hyun-Jin;Cho, Hang-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.196-203
    • /
    • 2008
  • Durability of geosynthetics for soil reinforcement is accounted for creep and creep rupture, installation damage and weathering, chemical and biological degradation. Among these, the long-term creep properties have been considered as the most important factors which are directly related to the failure of geosynthetic-reinforced soil(GRS). However, the creep test methods and strain limits are too various to compare the test results with each other. The most widely used test methods are conventional creep test, time-temperature superposition and stepped isothermal method as accelerated creep tests. Recently developed design guidelines recommend that creep-rupture curve be used to determine the creep reduction factor($RF_{CR}$) which is a conservative approach. In this study, the different creep test methods were compared and the creep reduction factors were estimated at different creep strain limits of 10% of total creep strain and creep rupture. In order to minimize the impact of creep strain to the GRS structures, the various creep reduction factors using different creep test methods should be investigated and then the most appropriated one should be selected for incorporating into the design.

  • PDF

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

A Comparative Study on Methods of Jury Test used for Sound Preferences (소리 선호도 조사에 사용하는 청음평가법의 비교 연구)

  • Jo, Hyeonho;Seong, Wonchan;Kim, Seonghyeon;Park, Dongchul;Kang, Yeonjune
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.165-170
    • /
    • 2014
  • Quantifying the perception of human is of great interest for the optimal characterization of the interaction of persons with their environment. The direct approach to such measurements is based on jury-test methods. In this study we considered which jury-test method is more efficient and exact way to measure the preferences for operating sound of car. Moreover we needed to research selection criteria of jury-test methods in accordance with the properties of sound samples. We choose two sample sounds; door locks which generate simple impact sounds and window lifts which are consisted of long and complex sound. For each sound sample we conducted two jury-test methods respectively and discussed about the results.

  • PDF

Critical Pitting Temperature of 2205 Duplex Stainless Steels Using Immersion and Electrochemical Polarization Test Methods (침지시험법 및 전기화학적 분극법에 의한 2205 이상 스테인리스강의 임계공식온도 측정 비교)

  • Shin Jae-Ho;Lee Jae-Bong
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.1
    • /
    • pp.18-24
    • /
    • 2006
  • Although stainless steels have the excellent corrosion resistance by passive film, they are susceptible to pitting corrosion in the environment containing halogen elements such as chloride ions. The resistance to pitting corrosion can be evaluated by measuring the critical pitting temperature (CPT). CPT values can be obtained using immersion, potentiodynamic and potentiostatic polarization test methods. Results on duplex 2205 stainless steels showed that CPT values were measured as $50^{\circ}C,\;55^{\circ}C\;and\;61^{\circ}C$, respectively for immersion, potentiodynamic and potentiostatic polarization test methods, depending upon the different test methods, even though the difference between CPT values are not much.

Pregnancy Diagnosis for Improvement of Reproductive Efficiency in Farm Animals (가축번식효율 증진을 위한 임부진단방법)

  • 정영채
    • Korean Journal of Animal Reproduction
    • /
    • v.7 no.2
    • /
    • pp.8-26
    • /
    • 1983
  • Various early pregnancy diagnostic methods have been developed in order to improve the reproductive efficiency in cow, mare, mule, sow, sheep, goat, dog, cat, rabbit, buffalo, camel, elephant, monkey, deer, lion, coipus and guinea pig. These methods include abdominal swelling, abdominal palpation, esturs cylce detection, Lupin test, gonadotropin assay, colostrum injection test, sperm motility assessment, cervical mucus viscosity test, Kaber chromagens method, estrogen test, A Scheim-Zond다 test, spectrophotometric detection of estrogen in urine and feces, boric acid crystraline formation test in urine, oxytocin injection test, diamino-oxidase test, PMSG HA test, behaviour test, Simolus iodine detection test, detection of tryptophane in urine, x-ray method, Cuboni and Lunaas method, vaginal biopsy method, Friedmann Schneider diagnostic method, electrode method, barium chloride detection method, ECG, Doptone method, ultrasound method, ultrasound scanning method, LDH method, rectal palpation method, CL palpation method, radioautography, serum creatine test, serum globulin test, chlormadine method, CAP method, Medata Do, pp.ers method, body fluid test, Plasma oCS detection method, ERIA, LHRH method, negative latex cogulation test and oestrone sulphate detection method. The most reliable methods with high a, pp.icability to farm animals such as sheep, mare, sow and cow are rectal palpation, ultrasound method and hormonal assay in blood and milk. However, they require complicated laboratory works for the early diagnosis of pregnancy and in most cases, the simple and economical methods which are described up to now need a long period of time after conception. Generally, it is possible to detect pregnancy after one estrus cycle, even though it varies depending on the species of animals. For improvement of the reproductive efficiency, it is required to develop a more accurate, economical, simple and early detectable method. It is anticipated that the result of a study on the detection method of EPF(early pregnancy factor) would be a, pp.icable to various animals within 6 hours after conception.

  • PDF

Reliability of Three Methods for Measuring Length of Iliotibial Tract (엉덩정강근막띠의 길이 평가를 위한 세 가지 측정방법들의 신뢰도 비교)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • The purpose of this study was to compare the intra-rater and inter-rater reliability of three methods for measuring iliotibial tract length in 40 knees of 20 subjects. The measurements were performed by two examiners and one assistant. The length of the iliotibial tract was measured using three methods: the first used a modified Ober test with an inclinometer, the second used a modified Ober test with a marker, and the third used active adduction test with a marker in the supine position. Each examiner used the three methods in two sessions. For the first method, the inclinometer value was recorded manually. For the second and third methods, Image J analysis software was used to analyze the photographs taken. The intra-rater and inter-rater reliability of the measured value was assessed by means of intra-class correlation coefficients [ICC (3,1)] and the standard error of measurement. The intra-rater reliabilities of the three methods were excellent (ICC=.97, .95, and .94, respectively), and the inter-rater reliabilities of the first and second methods were fair to good (ICC=.64 and .65, respectively). The inter-rater reliability of the third method was excellent (ICC=.88). Our results suggest that the active adduction test is an objective and qualitative measurement method for measuring iliotibial tract length. We recommend that the active adduction test be used for measuring iliotibial tract length in the clinical setting.