• Title/Summary/Keyword: test house

Search Result 755, Processing Time 0.038 seconds

Genernal Pharmacological and Acute/Subacute Toxicity Test of House Dust Mite Extract in Mice, Rats, and Guinea pigs (마우스, 랫트, 해명에서 집먼지 진드기 추출물의 일반 약리시험과 급성 및 아급성 독성에 관한 연구)

  • 노재열;김경환
    • Toxicological Research
    • /
    • v.14 no.2
    • /
    • pp.183-191
    • /
    • 1998
  • It has been reported that 50~70% of child asthma, bronchial asthma in adult, and allergic rhinitis are caused by house dust mite. The antigen extracted from house dust mite has been used for effective treatment against allergic diseases and for clinical test. This house dust mite antigen has been entirely imported from abroad. However, the composition and content of all the antigen imported vary from a brand to other brand. Thus, we need to standardize the composition and content of the antigen by developing it domestically. We proceeded pre-clinically general pharmacological test and toxicological test that are required for the eventual human use by utilizing the house dust mite cultured in Korea. In order to obtain information on general pharmacological tests such as its toxic signs in tissues or organs which are mainly affected, we examined the effect of house dust mite on the tensions of the isolated tissues and heart rates of cardiac muscle by recording with force displacement transducer of polygragh (Glass Model 7). We determined lethality of antigen extracted from house dust mite in mice and guinea pigs. We examined acute and subacute toxicity by administrating house dust mite extract of 500, 100, 20 times of the expected clinical dose. In male and female mice and guinea pigs, given a sigle intraperitoneal dose of antigen, $LD_{50}$ values were over 5.0 $\textrm{m}{\ell}$/kg, respectively. In animals administrated with house dust mite, there were no significant change of clinical symptom, body weight, food consumption, water consumption, eye examinations, urinalysis, blood biochemistry, and histopathological examinations in any animals tested. We found no toxic effect of this house dust mite. These results show that the house dust mite cultured by us could be used in the development of medicine against allergic diseases caused by the antigen of house dust mite.

  • PDF

Consistency Test in the House of Quality using Permutation Test (순열검정을 이용한 품질의 집의 일관성 검정)

  • Kim, Kyungmee O.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.1
    • /
    • pp.42-48
    • /
    • 2008
  • The house of quality (HOQ) involves subjective and ambiguous information typically through a likert scale, It isimportant to validate consistency of such input in the HOQ before rating the fmal importance of technicalrequirements, Previously, a methodology was developed to test the consistency of relationship strengths in theHOQ between roof matrix and relationship matrix. We described disadvantages of the previous method andpropose a new approach based on the permutation test. Advantages of the proposed method are illustrated withan example.

The Study on the New Traditional Korean-style house condition & Improvement Direction for Jeonnam region Rural Houses -Focus of Yeongam-gun & Yeosu region- (전남지역 신축 농촌한옥 현황 및 개선방향에 관한 연구 -영암군 및 여수 지역을 중심으로-)

  • Jo, Yeon-Jun;Jo, Giran
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.4
    • /
    • pp.45-52
    • /
    • 2010
  • The study has effected checking the traditional Korean-style house condition in Farm village and the resident preference test in jeonnam area for examination propriety of development a traditional Korean-style house. Also, it was checked over the problem and improvement direction of new building the Korean style house. The resident wanted living in the traditional Korean-style house if it is compromised problem of living equipment and cost of building. First. Jeonnam area Korean style house must keep the 'ㅡ' type plan. Second, the plan must construct compact and effective plan with the main floored room as the center for prevention against an indiscreet plan space extend of outside. Third, it has must need suitable material and construction for applying traditional exterior with effect. Fourth, it has must need actualization plan for the cost of construction is 3,500,000/py for construction.

A development of test and evaluation equipment for pulsed doppler radar (펄스도플러 레이더 시험장치 개발)

  • 신현익;이정욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.154-162
    • /
    • 1996
  • The test and evaluation is a integal part of the radar development process and it consists of two parts, field test and in-house test using a standard simulated signal. To take the in-house test, the test environment is needed to generate the critical signal that is used to determine the system design parameters and consists of general urpose measurement equipments, specialized boards and operating softwares. This paper presents the in-house test environment configuration and its function for radar system. Because this test environment genrates the simulated radar signal which has arbitrary flight path and target condition, the developed test environment makes easily to evaluate the function for radar system. The program ability of test parameters makes it possible to apply a test for 2D and 3D radar system.

  • PDF

Experimental and computational study of acoustic performance of the aircraft hush house (항공기 소음 저감시설의 음향 성능 관련 실험 및 예측에 관한 연구)

  • Jung, Hwan-Ik;Kim, Kwan-Ju;Park, Jin-Kyu;Kim, Sang-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.754-757
    • /
    • 2005
  • Aircraft noise is the serious problem for inhabitants near an air force base. Noise by ground test of aircraft, however, can be minimized through test room construction. In this study, environmental effects of the noise by aircraft ground test were investigated by experiments under the standard act and by performance, prediction of the Hush house, constructed for the noise reduction.

  • PDF

A Study on Development of Work Wear for the Plastic House Workers (비닐 하우스용 작업복 개발에 관한 연구)

  • Myung, Ji Young;Shim, Huen Sup;Choi, Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.1
    • /
    • pp.19-35
    • /
    • 1993
  • This study was designed to devise work wear for plastic house worker. It was carried out (1) research on the clothing actual condition through interviewings with plastic house worker and observations, (2) thermal manikin test to measure thermal resistance of experimental clothes and (3) clothing comparing test in the laboratory and in the plastic house. In the laboratory experiment, it was choosen general type (A) and new devised types (B, C) made of microporous fabric for experimental clothes. Experimental clothes were made of 6 combinations including 3 type work wears (A, B, C) and 2 type underwears (1, 2). In the plastic house experiment, it was choosen general types of A (without rest place) and B (with rest place), and devised type C (with rest place), which was appeared good effect in the laboratory experiment. The results were as followings. 1. Work environment of the plastic house in summer and winter was very different from the outer environment. Work motion in the plastic house was burden to the plastic house workers. 2. Plastic house workers had on the general type's work wear. 3. As a result of thermal manikin test, thermal resistance was appeared B1>B2>C2>C1>A1>A2 in orders. 4. In the laboratory experiment, experimental clothes A was appeared smaller burden than B, C. Effect of mesh underwear was not appeared in this study condition. In subjective sensation, experimental clothes C was lower vote than A. Therefore experimental clothes C was superior to A in subjective wearing sensation. 5. In the plastic house experiment, the experimental conditions with rest place were appeared smaller burden than without rest place. General type B was appeared more positive physiological reactions than devised type C but significances between two types was not appeared.

  • PDF

A Full-scale Fire Test of an Apartment House (공동주택 실물화재 실험)

  • Kim, Myung-Bae;Han, Yong-Shik;Choi, Byung-Il;Do, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2009
  • To research about the fire spread in Korean apartment house, a full-scale fire test in a four-story apartment was executed. The fire started at the third floor, and originated from overheated cooking oil in the kitchen. The apartment included all combustibles in general house. Through measuring temperature, measuring the concentration of oxygen and observing, we investigated the fire spread inside the apartment house. As a result, we got the data of the time needed for the initiation of fire, the time for fire to spread into each area in the house, and the time required until flash-over was seen. Also we grasped the understanding of the fire spread to the upper floor.

Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions (기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성)

  • Song, ChangSeob;Jang, UngHee;Choi, DookHo;Kim, JungChul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.

Seismic performance evaluations of modular house having 4-clip fastening method (4-클립 체결방식을 갖는 모듈러 하우스의 내진성능평가)

  • Lim, Hyeon-jin;Cho, Chang-Geun;Shin, Jung-Kang;Lee, Sun-Joo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.41-48
    • /
    • 2022
  • The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.

A Test on the Aseismic Capacity of a Traditional Three-bay-straw-roof House(I) : Rock Site Condition (전통 초가삼간 가옥의 내진성능 평가 실험(I) : 암반지반 조건)

  • 서정문;최인길;전영선;이종림;신재철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.11-20
    • /
    • 1997
  • The aseismic capacity of a traditional three-bay-straw-roof wooden house for rock site condition is quantitatively estimated. One 1/4 scale model was tested for the Nahanni Earthquake with peak ground accelerations from 0.1g to 0.6g. The natural frequency of the wooden house in elastic range is 1.66 Hz and 2.15 Hz in longitudinal and transversal direction, respectively. Damping ratio of the house in elastic range is 7%. The horizontal acceleration response of the house is significantly reduced compared with the input motion due to the nonlinear inelastic characteristics of the Sagae-machum joint of the frame. The traditional wooden house has high aseismic capacity in the rock site condition where high frequency contents of motion are predominant.

  • PDF