• Title/Summary/Keyword: test fixture

Search Result 182, Processing Time 0.023 seconds

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.

THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION (구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교)

  • Huh, Jung-Bo;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY (임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향)

  • Oh, Gap-Yong;Park, Sung-Hwa;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

Displacement of scan body during screw tightening: A comparative in vitro study

  • Kim, JungHan;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.307-315
    • /
    • 2020
  • PURPOSE. The purpose of this study was to evaluate the occurrence of displacement while tightening the screw of scan bodies, which were compared according to the material type. MATERIALS AND METHODS. Three types of scan bodies whose base regions were made up of polyether ether ketone (PEEK) material [Straumann Group, Dentium Group, and Myfit (PEEK) Group] and another scan body whose base region was made up of titanium material [Myfit (Metal) Group] were used (15 per group). The reference model was fabricated by aligning the scan body library on the central axis of the implant, and moving this position by the resin model. The screws of the scan bodies were tightened to the implant fixture with torques of 5 Ncm, 10 Ncm, and a hand tightening torque. After the application of the torque, the scan bodies were scanned using a laboratory scanner. To evaluate the vertical, horizontal, and 3-dimensional (3D) displacements, a 3D inspection software program was used. To examine the difference among groups, one-way analysis of variance and Tukey's HSD post hoc test were used (α=.05). RESULTS. There were significant differences in 3D, vertical, and horizontal displacements among the different types of scan bodies (P<.001). There was a significantly lower displacement in the Straumann group than in the Myfit (PEEK) and Dentium groups (P<.05). CONCLUSION. The horizontal displacement in all groups was less than 10 ㎛. With the hand tightening torque, a high vertical displacement of over 100 ㎛ occurred in PEEK scan bodies (Myfit and Dentium). Therefore, it is recommended to apply a tightening torque of 5 Ncm instead of a hand tightening torque.

A COMPARATIVE ANALYSIS WITH RESONANCE FREQUENCY ACCORDING TO VARIOUS SIMULATED BONE DEFECTS (다양한 가상 골 결함에 따른 공진 주파수의 비교 분석)

  • Kim Sang-Mi;Park Chan-Jin;Yi Yang-Jin;Chang Beom-Seok;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.487-497
    • /
    • 2005
  • Purpose: Resonance frequency analysis (RFA) , a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitro study evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined self-tapping implant future were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc $Sch\`{e}ffe'$ test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-$360^{\circ}$ group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion : Although the simulated defect type was different from each other, the ISQ value was similar among groups.

High Speed Tensile Tests of Steel Sheets for an Auto-body at the Intermediate Strain Rate (중변형률 속도에서의 차체용 강판의 고속 인장실험)

  • Lim, Ji-Ho;Kim, Seok-Bong;Kim, Jin-Sung;Huh, Hoon;Lim, Jong-Dae;Park, Sung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.127-134
    • /
    • 2005
  • This paper introduces a newly developed high speed material testing apparatus for tensile tests at the strain rate up to 500/sec. The tensile properties of sheet metals are indispensable for the accurate crashworthiness analysis of auto-bodies since the local strain rate reaches to 500/sec in the car crash. An appropriate experimental method has to be developed to acquire the tensile properties at the intermediate strain rate ranged from 0.003/sec to 200/sec. Tensile tests of various different steel sheets for an auto-body were perform ed to obtain the dynamic properties with respect to the strain rate. The dimensions of specimens that can provide the reasonable results were determined by the finite element analysis. A special jig fixture of a load cell is designed to reduce the load ringing phenomenon induced by unstable stress propagation at the high strain rate. Stress-strain curves were acquired for each steel sheet from the dynamic tensile test and utilized to obtain the relationship of the stress to the strain rate.

SURVIVAL RATE OF THE DENTAL IMPLANTS PLACED IN POSTERIOR MAXILLA WITHOUT SINUS AUGMENTATION (상악동 골이식술 없이 상악 구치부에 식립된 임프란트의 생존율)

  • Park, Hye-Won;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.3
    • /
    • pp.170-175
    • /
    • 2009
  • Purpose : The purpose of this study is to evaluate 7-year survival rate of implants placed without bone graft in posterior maxilla and compare the survival rate by the age and gender of patient, length and diameter of implant, region of implant placement, bicortical engagement of fixture, and connection of prosthesis. Material and methods : 78 patients (170 implants) who visited our institution from 2002 to 2007 and were followed up with panoramic view and medical records. Kaplan-Meier survival analysis and Log Rank (Mantel-Cox) test were used. Results and conclusions : A 7-year cumulative survival rate for implants placed in posterior maxilla without sinus graft was 95.3%. The survival rate in men was 91.8%, significantly lower than 98.8% in woman.(p<0.05). However, the survival rate by the length of the implants did not show any significant differences.(p>0.05), while the wide platform implant resulted in 85% survival rate which was statistically lower than 98.5% in regular platform. The posterior maxillary implants engaged bicortically showed 97.6% of 7-year Survival rate, comparing 88.6% in not engaged implants. The survival rate of the single implant was 91.2%, while 98.5% in splinted prosthesis. Therefore, the bicortical engagement of the fixtures and splinted prosthesis may be recommended to get a long-term survival rate in posterior maxilla.

Variation of Characteristics of Solenoid-Type RF Chip Inductors on Inductor Size (인덕터 크기에 따른 솔레노이드 형 RF 칩 인덕터 특성 변화)

  • Yun, Eui-Jung;Kim, Jae-Wook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.7
    • /
    • pp.339-343
    • /
    • 2006
  • In this study, the variations of the important characteristics of solenoid-type RF chip inductors utilizing a low-loss A1203 core material on inductor dimensions were investigated systematically. Four dimensions of the chip inductors fabricated in this work were $1.0\times0.5\times0.5mm^3,\;1.5\times1.0\times0.7mm^3,\;2.1\times1.5\times1.0mm^3,\;and\;2.4\times2.0\times1.4mm^3$ and copper (Cu) wire with $40{\mu}m$ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors as a function of inductor dimensions were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 6 have the inductance (L) of 12 to 82 nH and exhibit the self-resonant frequency (SRE) of 3.6 to 1.2 GHz. The SRF of inductors decreases with increasing the inductor size while the L increases with the inductor size. The smallest inductors of $1.0\times0.5\times0.5mm^3$ exhibited the L of 12 nH, SRF of 3.6 GHz, and the quality factor of 67 near the frequency of 1.1 GHz. The calculated data predicted the high-frequency data of the L, and Q of the developed inductors well.

A Study of Postural Sway and Dynamic Standing Balance with Low Back Pain (요통환자의 자세동요와 동적기립균형에 관한 연구)

  • Yang, Dae-Jung;Song, Tae-Ho;Lim, Ho-Yong;Ahn, Yeon-Jun;Park, Seung-Kyu;Kim, Yeong-Rok
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.2
    • /
    • pp.18-26
    • /
    • 2004
  • The purpose of this study was to compare difference of the static and dynamic balance in normal subject and LBP subject and recognizes about postural sway. The subjects of this study included 30 normal subjects and 30 LBP subjects. By using Active balance system, the static balance was measured by unit path length, circumference area, weight bearing, stabilometry length, while the dynamic balance was measured by step evaluation. Statistically analyzed using independent t-test to search static balance and dynamic balance difference in two groups. Postural sway appeared greatly in patient group than normal group in analysis result of static balance and postural sway was big in patient group of when closed eye and normal group and patient group did show statistical significance in unit path length, circumference area. Weight support of normal group was shared equally in weight bearing rate, but weight support of patient group stewed less to pain side. Anterior step time and Task achieve time of dynamic balance were spent more in patient group than normal group. Desire to be used to useful information to lay treatment policy about set-up and action of when quantification result of valued postural balance treats low back pain patient by objective tool, in the fixture, more researches in postural estimation desire that is enforced abuzz.

  • PDF

Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits

  • Kim, Jong-Ryoul;Kim, Sung-Hee;Kim, In-Ryoung;Park, Bong-Soo;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.2-8
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the effects of low-level laser therapy (LLLT) with a diode gallium-aluminum-arsenide (Ga-Al-As) low-level laser device on the healing and attachment of titanium implants in bone. Materials and Methods: Thirteen New Zealand white male rabbits weighing $3.0{\pm}0.5kg$ were used for this study. Dental titanium implants (3.75 mm in diameter and 8.5 mm in length, US II RBM plus fixture; Osstem, Seoul, Korea) were implanted into both femurs of each rabbit. The rabbits were randomly divided into a LLLT group and a control group. The LLLT was initiated immediately after surgery and then repeated daily for 7 consecutive days in the LLLT group. Six weeks and 12 weeks after implantation, we evaluated and compared the osseointegration of the LLLT group and control group, using histomorphometric analysis, removal torque testing, and resonance frequency analysis (RFA). The results were statistically significant when the level of probability was 0.05 or less based on a non-parametric Mann-Whitney U-test. Results: The implant survival rate was about 96%. Histologically and histomorphometrically, we observed that the titanium implants were more strongly attached in LLLT group than in control group. However, there was no significant difference between the LLLT group and control group in removal torque or RFA. Conclusion: Histologically, LLLT might promote cell-level osseointegration of titanium implants, but there was no statistically significant effects.