1 |
Albrektsson T, Branemark PI, Hansson HA, Lindstro J. Osseointegrated titanium implants.: Requirements for ensuring a long lasting, direct bone anchorage in man. Acta Orthop Scand 1981;52:155-170
DOI
PUBMED
ScienceOn
|
2 |
Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25
PUBMED
|
3 |
Pjetursson BE, Tan K, Lang NP, Bragger U, Egger M, Zwahlen M. A systemic review of the survival and complication rates of fixed partial dentures(FPDs) after an observation period of at least 5 years. I. Implant-supported FPDs. Clin Oral Impl Res 2004;15:625-642
DOI
|
4 |
Robinson HBG, Lefkowitz W. Operative dentistry and the pulp. J Prosthet Dent 1962;12:985-1001
DOI
|
5 |
Pauletto N, Lahiffe BJ, Walton JN. Complications associated with excess cement around crowns on osseointegrated implants: a clinical report. Int J Oral Maxillofac Implants 1999:14:865-868
|
6 |
Gross M, Laufer BZ, Ormianar Z. An investigation on heat transfer to the implantbone interface due to abutment prreparation with high-speed cutting instruments. Int J Oral Maxillofac Implants 1995;10:207- 212
|
7 |
Guichet DL, Caputo AA, Choi H, Sorensen JA. Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000;15:239-246
|
8 |
Schuchard A, Watkins C. Temperature response to increased rotational speeds. J Prosthet Dent 1961;11:313-317
DOI
|
9 |
Goodis HE, Schein B, Stauffer P. Temperature changes measured in vivo at the dentoenamel junction and pulpodentin junction during cavity preparation in the Macaca fascicularis monkey. J Endod 1988;14:336-339
DOI
ScienceOn
|
10 |
Bachus KN, Rondina MT, Hutchinson DT. The effects of drilling force on cortical temperatures and their duration: an in vitro study. Med Eng Phys 2000;22:685-691
DOI
ScienceOn
|
11 |
Lockard MW. A retrospective study of pulpal response in vital adult teeth prrepared for complete coverage restorations at ultrahigh speed using only air coolant. J Prosthet Dent 2002;88:473-478
DOI
ScienceOn
|
12 |
Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit. J Prosthet Dent 1983;50:101-107
DOI
ScienceOn
|
13 |
Bragger U, Wermuth W, Torok E. Heat generated during preparation of titanium implants of the ITI dental implant system: an in vitro study. Clin Oral Impl Res 1995; 6:254-259
DOI
ScienceOn
|
14 |
Hur JK, Kay KS, Chung CH. Finite element stress analysis of implant prosthesis according to connection types of implant-abutment. The Journal of Korean Academy of Prosthodontics 2005;43:545-561
|
15 |
Schenk R, Hunziker EB. Histologic and ultrastructural features of fracture healing. In: Bone formation and repair. Rosemont, IL: American Academy of Orthopaedic Surgeons. 1994:117-146
|
16 |
Lee JW, Kim CW, Jang KS, Lim YJ. The effect of preparation procedure on implant abutment joint stability. The Journal of Korean Academy of Prosthodontics 2005;43:662-670
|
17 |
Stanley HR, Swerdlow H. Biological effects of various cutting methods in cavity preparation: the part pressure plays in pulpal response. J Am Dent Assoc 1960;61:450- 456
DOI
|
18 |
Esposito M, Thomsen P, Ericson LE, Sennerby L, Lekholm U. Histopathologic observations on late oral implant failures. Clin Implant Dent Relat Res. 2000;2:18-32
DOI
ScienceOn
|
19 |
Maeda Y, Satoh T, Sogo M. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. J Oral Rehabil 2006;33:75-78
DOI
ScienceOn
|
20 |
Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. Eur J Oral Sci 1998;106:527-551
DOI
ScienceOn
|
21 |
Roberts WE. Bone tissue interface. J Dent Educ 1988:52;804-809
PUBMED
|
22 |
Brunski JB. In vivo bone response to biomechanical loading at the bone/dentalimplant interface. Adv Dent Res 1999: 13;99-119
DOI
ScienceOn
|
23 |
Taylor TD, Agar JR. Twenty years of progress in implant prosthodontics. J Prosthet Dent 2002;88:89-95
DOI
PUBMED
|
24 |
Kim YL, Cho HW, Lee JB. Threedimensional finite element analysis of internally connected implant systems. The Journal of Korean Academy of Prosthodontics 2006;44:85-102
과학기술학회마을
|