• 제목/요약/키워드: test fixture

검색결과 182건 처리시간 0.03초

$\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구 (Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report)

  • 장진화;류경호;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구 (Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model)

  • 권택가;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.128-137
    • /
    • 2011
  • 연구 목적: 자기공명주파수 분석, 페리오테스트, 풀림 토크는 임플란트의 안정성을 측정하기 위한 방법으로 알려져 있다. 이 방법들은 골 상태와 임플란트 형태에 영향을 받는다. 본 연구에서는 골유착이 재현된 아크릴 레진 실험 모델에서 임플란트가 결합된 골의 양을 변화하고 경부의 골 상실양이 증가하였을 경우, 자기공명주파수 분석, 페리오테스트, 풀림 토크 측정에 어떠한 영향을 주는지 알아보고 이들 상호간의 관계를 알아보고자 하였다. 연구 재료 및 방법: 골 유착을 재현하기 위하여 임플란트를 알루미늄 틀에 나사로 고정한 후 자가중합형 아크릴릭 레진의 가루와 용액을 틀 안에 부어서 중합을 시켰다. 임플란트와 결합된 레진의 두께를 조정하여 골 결합 두께를 각각 1, 3, 5, 10 mm인 경우로 재현하였다. 그 후 임플란트 주변 경부 골 상실 양이 1, 3, 5 mm인 경우를 재현하였다. 각각의 재현된 골 조건에서는 4 mm 직경의 직선형 임플란트, 같은 직경의 tapered 형 임플란트, 5 mm 직경의 tapered 형의 3가지 임플란트가 각각 5개씩 사용되었다. 모든 골 조건에서 자기공명주파수 분석과 페리오테스트 측정이 이루어졌으며 골 결합 두께 1, 3 mm 시편에서는 풀림 토크가 측정되었다. 결과: 골 결합 두께가 증가하거나 임플란트 직경이 증가할수록 통계적으로 유의하게 ISQ 값은 증가하였고, 페리오테스트 값은 감소하였다 (P<.001, P<.001). 임플란트 경부에 주위 골 상실 양이 커질수록 ISQ 값은 감소하였고, 페리오테스트 값은 증가하였다 (P<.001). ISQ 값과 페리오테스트 t값은 매우 강한 상관관계를 나타냈다 (r = -0.99, P<.001). ISQ값과 풀림토크는 약한 상관관계를 나타냈으며 (r = 0.52, P<.001), 페리오테스트 값과 풀림 토크도 약한 상관관계를 나타냈다 (r = -0.52, P<.001). 결론: 레진으로 재현한 골의 양이 증가할수록, 임플란트의 직경이 증가할수록, 경부의 골 상실양이 적을수록 임플란트 안정성이 증가함을 확인할 수 있었다. 또한 본 연구에서는 ISQ 값과 페리오테스트 값의 강한 상관관계를 밝힐 수 있었다.

하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가 (Bone density around the fixture after function of implant molar prosthesis using CBCT)

  • 정재현;황인택;정병현;김재덕;강동완
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

하악 부분 무치악 환자의 골유착성 임플랜트 주위 연조직에 관한 연구 (The study of the peri-inplant soft tissue around osseointegrated implants in partial edentulous patients)

  • 정근식;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제27권3호
    • /
    • pp.561-573
    • /
    • 1997
  • The keratinized mucosa around the implant is an important key in health of soft tissue and hard tissue. The purpose of this study is showed that the keratinized mucosa is associated with the keratinized mucosa index, plaque index, gingival index, probing depth. which is investigated to observing the peri-implant mucosa of mandibular partial edentulous patuent using periodontal parameter by previously published paper. It was estimated 6 site with regard to 80 fixture for 28 person, and the average age is 46.8. Each estimation is the order of less trauma, that is, plaque index, keratinized mucosa index, gingival index and probing depth. In this study, statstically analyzed treatment is used for Spss V 7.0 for Windows(Spss Inc, USA). The Kruskal Walis Test is used to compare the amount of the keratinized mucosa is into the $0{\sim}3$ index, with plaque index, gingival index and probing depth. Mann-whitney Test is used to interpreate the relation of plaque index and probing depth, which is showed significant difference. The Result are as follows 1. The kertinized mucosa index 3 amounts to 47.7%, which is much higher than the other indices and the index order is followed 3, 1, 2 and O. 2. The plaque index 1 amounts to 61.7%, which is much higher than the other indices and the index order is followed 1, 2, 3 and O. The plaque index 0 is significant to each of index(P<0.05). The plaque index is decrease as the keratinized mucosa index is increased. 3. The probing depth for 2mm, 1mm, 3mm is 48.9%, 23.5%, 16.8% respectively, which is most occupied. The probing depth 2mm and 3mm for the keratinized mucosa index is significant(P<0.05). The probing index is decreased as the keratinized mucosa index is increased. 4. The gingival index 0 amounts to 58.0%, which is much higher than the other indices and the index order is followed 0, 1, 2 and 3.

  • PDF

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

Piezo Sensor Signal에 의한 수면의 질 Algorithm에 관한 연구 (A Study on Sleep Quality Algorithm by Piezo Sensor Signal)

  • 변재령;조위덕;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.324-326
    • /
    • 2011
  • 수면 중 생체 신호를 측정하는 것은 수면 장애 진단 및 치료의 중요한 부분을 차지하며, 전반적인 수면의 질을 판단하는 방법으로 사용되고 있다. 현재 수면다원검사와 같이 수면중 생체 신호를 측정하는 방법은 몸에 전극을 부착하는 접촉식 방법이 사용되고 있다. 이는 수면 중 움직임에 제약을 받고, 매 측정 시 마다 탈부착을 해야 하는 번거러움과 고통을 유발하게 된다. 이러한 필요성으로 인해 무구속적 방식으로 생체 정보를 획득하려는 연구가 활발히 진행되고 있는 상태이다. 따라서 본 논문에서는 필름 타입의 압력센서인 피에조 (Piezo)를 침대에 설치하여 직접적인 접촉과 구속감이 없이 분당 심박 수를 산출하고, 호흡의 유무를 판단하는 방법에 대해 제안하였다.

  • PDF

미소 표면변형 관찰을 통한 가스배관 부재의 항복특성 평가 (Assessment of Yield Characteristics of Gas Pipeline Materials by Observing Surface-Local Deformation)

  • 이윤희;백운봉;정인현;남승훈;이상혁
    • 한국가스학회지
    • /
    • 제12권2호
    • /
    • pp.92-98
    • /
    • 2008
  • 가스배관 열화부재의 실시간 역학물성 측정기술로 계장화 압입과 압입흔적 입체측정의 융합이 시도되었다. 압입하중-변위곡선을 계장화 압입시험으로 획득한 후 반사식 레이저 스캔너를 이용하여 압입흔적을 3차원으로 관찰하였다. 압흔 단면프로파일로부터 소성역 크기와 실제 접촉경계를 분석할 수 있었고, 두 값을 이용하여 소재의 항복강도와 경도를 계산하였다. 항복강도는 단축 인장시험에서 얻어진 값과 유사한 경향을 나타내었고, 경도는 재료쌓임 영향으로 압입곡선에서 계산된 값에 비해 $20{\sim}30%$ 낮은 값을 나타내었으나 최대 인장강도와 정량적인 관련성이 있음을 확인할 수 있었다. 덧붙여 압입하중 인가부의 형태를 수정하여 압입시험과 동시에 압흔주변 형상변화를 측정하기 위한 시스템도 고안되었다.

  • PDF

Transfer learning in a deep convolutional neural network for implant fixture classification: A pilot study

  • Kim, Hak-Sun;Ha, Eun-Gyu;Kim, Young Hyun;Jeon, Kug Jin;Lee, Chena;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.219-224
    • /
    • 2022
  • Purpose: This study aimed to evaluate the performance of transfer learning in a deep convolutional neural network for classifying implant fixtures. Materials and Methods: Periapical radiographs of implant fixtures obtained using the Superline (Dentium Co. Ltd., Seoul, Korea), TS III(Osstem Implant Co. Ltd., Seoul, Korea), and Bone Level Implant(Institut Straumann AG, Basel, Switzerland) systems were selected from patients who underwent dental implant treatment. All 355 implant fixtures comprised the total dataset and were annotated with the name of the system. The total dataset was split into a training dataset and a test dataset at a ratio of 8 to 2, respectively. YOLOv3 (You Only Look Once version 3, available at https://pjreddie.com/darknet/yolo/), a deep convolutional neural network that has been pretrained with a large image dataset of objects, was used to train the model to classify fixtures in periapical images, in a process called transfer learning. This network was trained with the training dataset for 100, 200, and 300 epochs. Using the test dataset, the performance of the network was evaluated in terms of sensitivity, specificity, and accuracy. Results: When YOLOv3 was trained for 200 epochs, the sensitivity, specificity, accuracy, and confidence score were the highest for all systems, with overall results of 94.4%, 97.9%, 96.7%, and 0.75, respectively. The network showed the best performance in classifying Bone Level Implant fixtures, with 100.0% sensitivity, specificity, and accuracy. Conclusion: Through transfer learning, high performance could be achieved with YOLOv3, even using a small amount of data.

기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교 (A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment)

  • 김종욱;허유리;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.276-283
    • /
    • 2013
  • 연구 목적: 본 연구에서는 기성 지대주와 맞춤형CAD-CAM 지대주의 적합성 및 나사 사이의 안정성 대해 알아보고자 한다. 연구 재료 및 방법: 오스템 임플란트 시스템을 이용하였다. 동일회사에서 제작된 기성 지대주(Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea) 및 맞춤형CAD-CAM 지대주(CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea)와 국내 외주 제작된 맞춤형CAD-CAM 지대주(Myplant, Raphabio Co., Seoul, Korea)를 5개씩 선택, 제작하였으며 나사는 각 회사에서 제공되는 것을 사용하였다. 제조사의 지시에 따라 고정체와 지대주를 30 Ncm으로 조인 후 초기 풀림 토크를 3회 반복 측정한 후 통계 분석하였다(${\alpha}=.05$). 고정체-지대주 연결체를 에폭시 레진에 매몰 후 습식 절삭 및 연마하여 계면 사이의 적합성을 FE-SEM으로 관찰하였다. 결과: 지대주의 초기 풀림 토크 값은 각각 기성 지대주(Transfer abutment)에서 $26.0{\pm}0.30Ncm$, 동일 회사에서 제작된 맞춤형CAD-CAM 지대주(CustomFit abutment)에서 $26.3{\pm}0.32Ncm$, 외주로 제작된 맞춤형CAD-CAM 지대주(Myplant abutment)에서 $24.7{\pm}0.67Ncm$였다. 국내 외주 제작된 맞춤형CAD-CAM 지대주에서 유의적으로 낮은 초기 풀림 토크 값을 보였으며(P=.027), 고정체-지대주 계면에서 변연 간극이 관찰되었다. 결론: 본 실험의 한계 내에서 국내 외주 제작된 맞춤형CAD-CAM 지대주는 동일 회사에서 제작된 기성 지대주나 맞춤형CAD-CAM 지대주에 비해 더 낮은 나사 안정성 및 적합성을 보인다고 볼 수 있다.