• 제목/요약/키워드: test fixture

검색결과 182건 처리시간 0.029초

조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구 (Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring)

  • 최충석
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

수직발사 유도탄의 진동시험에서 유도탄 장착방향의 영향에 대한 연구 (Study on the Effects of the Mounting Direction of Vertically-launched Missiles in Vibration Tests)

  • 이호준;김기언
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.218-225
    • /
    • 2013
  • Vertically-launched missiles are supported as erected vertically in the vertical launching system of warship, and they should be mounted in the same way when vibration-tested. However, mounting missiles vertically makes a fixture, which is a supporting structure, bulky and heavy so requiring a high-performance exciter. Mounting missiles as laid down horizontally in a vibration test is economical regarding fixture manufacturing and exciter performance, but it makes test results incorrect because the different mounting direction has effects on the test results. A bending moment due to missiles' weight happens to missiles, and resilient mounts, which support missiles in the vertical launch system, deflect differently from the real situation because of the static deflection of these mounts due to missiles' weight. If the resilient mounts supporting missiles have nonlinear force-deflection characteristics, vibration test results become more different from the true results. This paper proposes to support missiles with an additional resilient mount such as a bunge code in order to solve those problems coming from mounting vertically-launched missiles as laid down horizontally in vibration tests. The proposed approach enables to obtain the same test results as in their actual mounting condition even though vertically-launched missiles are mounted in a different direction.

복합재 적층판의 전단좌굴시험을 위한 치구 설계 및 검증 (Design and Verification of Shear Buckling Test Fixture for Composite Laminate)

  • 박성준;고명균;김동관;김상국;문창오;권진회;최진호
    • Composites Research
    • /
    • 제27권4호
    • /
    • pp.158-167
    • /
    • 2014
  • 본 연구의 궁극적 목표는 현장의 구조설계자들이 복합재 평판의 전단좌굴 설계허용치를 설정할 때 사용할 수 있는 환산계수(이론값과 실험값의 차이를 보정하는 계수)를 제공하는 것이다. 이를 위해서는 광범위한 시험과 해석이 필요하며, 본 연구에서는 일단계로, 복합재 평판의 전단좌굴시험을 위해 단축인장하중을 받는 프레임 형태의 치구를 설계하고, 시험과 해석을 수행하여 그 타당성을 검토하였다. 치구의 최종 형상은 시편의 크기, 치구의 치수, 체결볼트의 수 등의 변수들이 전단좌굴하중에 미치는 영향에 대한 인자연구를 통해 결정하였다. 시험 및 해석 결과, 설계된 프레임이 의도한대로 전단좌굴을 효과적으로 유도하는 것을 확인하였다. 그러나 시험에서는 시편이 치구에 고정되어야 하므로 시편의 크기가 달라지게 되어, 시험값과 해석값의 차이가 존재하였다. 특히 원공이 커질수록, 또한 단순지지 경계조건일 경우에는 그 차이가 더 크게 나타났다. 본 연구의 결과 고정지지 전단좌굴의 경우 설계된 프레임 형태 치구를 그대로 사용할 수 있을 것으로 보이지만, 단순지지 경계일 경우 경계조건 설정방법의 수정이 필요할 것으로 판단된다.

RF대역에서의 반도체 package 특성 측정에 관한 연구 (A Study on Measurement of Semiconductor Package in RF Regime)

  • 박현일;김기혁;황성우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.108-111
    • /
    • 2000
  • The electrical characteristics of MQFP packages have been measured in RF regime. The s-parameter of the lead frame has been measured using the test fixture on which the do-capped package was mounted. A simple lumped equivalent circuit modeling of the lead frame and the test fixture can provide reasonable model parameters up to the frequency of 200 MHz.

  • PDF

반공진 진동수 해석에 의한 치구 설계 변경 (Structural Dynamic Modification of Fixture using Antiresonance Frequency Analysis)

  • 김준엽;윤을재
    • 한국추진공학회지
    • /
    • 제1권2호
    • /
    • pp.48-57
    • /
    • 1997
  • 본 연구에서는 치구 설계단계에서 치구 위의 여러 시험물부착점들에서의 반공진 진동수들을 고려하여 그 감도를 계산하고, 치구의 구조변경을 수행하여 시험물부착점들에서의 반공진 진동수들을 일치시키므로서 종래의 진동시험제어시 나타나는 반공진 진동수에서의 문제점을 제거할 수 있고, 그 결과 시험물부착점들에서의 스펙트럼이 시험규격에 정해진 스펙트럼대로 진동시험이 수행될 수 있게 하는 데 있다. 그리고 충격가진실험을 통해 제안한 기법에 대한 실제 치구제작에 적용 가능성을 검증하였다.

  • PDF

랜덤진동제어에서 치구성능향상을 위한 기준스펙트럼의 최적화에 대한 연구 (A study on Optimization of Reference Spectrum for Improvement of Fixture Performance in Random Vibration Control)

  • 김준엽;정의봉
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.284-291
    • /
    • 1995
  • This paper proposes a method for determination of optimal reference spectrum in random vibration control. The least square method is used to minimize the spectrum deviation between the specified reference spectrum and spectra at the specimen-mounted points. This method needs only the measured FRF's at the control point and specimen-mounted points in pre-vibration test. Using the proposed method as reference spectrum, it is possible to easily predict spectra at the specimen-mounted points, and also to reduce overtest resulting from dynamic characteristics of shaker and fixture. This method is shown through theoretical and experimental results to be an effective method.

Fixture를 이용한 토양 절연파괴 실험 (Soil Breakdown Test using Fixture)

  • 이현구;하태현;정동학;하윤철;김대경;배정효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

EFFICIENT DESIGN OF CAPACITOR DISCHARGE IMPULSE MAGNETIZER SYSTEM FOR 8-POLE MAGNET

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.828-832
    • /
    • 1995
  • This paper describes the efficient design, analysis method and experimental verification of capacitor discharge impulse magnetizer system. A capacitor discharge magnetizer system is used to produce a high current impulse of short duration in this magnetizing fixture. The parasitic resistance and parasitic inductance of the capacitor discharge impulse magnetizer system have been estimated using known air-core test coil. Finite element analysis (using MAXWELL 2-D field simulator) and magnetizing circuit analysis (using SPICE) are also used as part of the design and analysis process of the capacitor discharge impulse magnetizer system. Application study for a magnetizing fixture design is shown. 8-pole magnetizing fixture has been designed and analyzed using finite element analysis. The fixture design for 8-pole magnet are presented along with the experimental results. The experimental results have been achieved using a high-voltage, high-energy capacitor discharge impulse magnetizer and 8-pole iron core fixtures (charging voltage : 2000[V], capacitor bank : 4000[$\mu\textrm{F}$]).

  • PDF

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

반복하중에 따른 수종 임플란트의 피로파절에 관한 연구 (Fatigue fracture of different dental implant system under cyclic loading)

  • 박원주;조인호
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.424-434
    • /
    • 2009
  • 연구목적: 임플란트는 수직교합 하중에는 비교적 잘 견디나 측방하중에 대해서는 약한 역학적 성질을 갖고 있으므로 임플란트의 재료 특성과 기하학적 형태에 따른 응력 분석 연구의 필요성이 제기되고 있다. 연구재료 및 방법: 외부육각구조를 갖는 28개의 임플란트를 7개씩 4군으로 나누어 그 제품에 적합한 UCLA gold abutment를 이용해, 제3형 금합금으로 보철 물을 제작하였고, A군 (3i, FULL $OSSEOTITE^{(R)}$-Implant), B군 (Nobelbiocare, Branemark $System^{(R)}$Mk III Groovy RP), C군 (Neobiotec, $SinusQuick^{(TM)}$ EB), D군 (Osstem, US-II)으로 분류하였다. 고정체와 지대주나사, 지대주를 연결한 후 수직적으로 절단하여 연마한 후 미세경도계를 이용하여 10군데에서 경도측정을 실시하였고, 동적하중 피로시험기를 이용하여 60-600 N범위로 파절시까지 동적 하중을 가하였다. 주사전자현미경을 이용하여 지대주나사 및 고정체의 파절 양상과 파절 위치 등을 관찰하였고, 유한요소분석을 통해 고정체와 지대주 나사에 나타나는 응력 분포와 파절면을 비교 분석하였다. 결과: 1.고정체 경도는 A, B, C, D군에서 각각 245.3, 289.7, 281.3, 300.4 Hv로 D군이 가장 높았고, A군이 가장 낮았다. 지대주 나사의 경도는 A, B, C, D군에서 각각 340.00, 317.62, 306.5, 306.2 Hv로 A군이 가장 높고, D군이 가장 낮았다. 2. 모든 실험군에서 임플란트 고정체의 파절은 응력이 집중되는 고정체 3-4번째 나사산 홈 (valley) 부위 또는 내면의 사공간부와 일치하는 부위에서 발생되었고, 피로수명은 A, B, C, D군에서 각각 31585, 47311, 30141, 105371로 D군이 가장 높았으며, A, B, C군과는 유의한 차이가 있었다(P<.05). 3. 파절양상은 B군과D군에서는 고정체와 나사 모두에서 수직 (longitudinal)파절과 수평 (transverse)파절이 동시에 일어나는 복합 (complex mode) 파절이 관찰 되었고, A와 C군에서는 고정체에서 수평 (transverse mode) 파절만이 관찰되었다. 4. 유한요소분석 결과 인장응력이 가장 높은 고정체 표면부에서 피로 균열이 시발되어 압축응력이 가장 높은 반대편 부위로 피로균열이 전파되었으며, 최대 유효 응력값은 C군이 가장 높았고, B군에서 가장 낮았다. 결론: 피질골 높이와 일치하는 임플란트 고정체 부위에서 최대 인장 주응력이 발생되며, 고정체 사공간부 (dead space)가 최대 인장 주응력이 작용하는 지그 표면과 일치할 때 피로파절이 발생되었다. 따라서 악골에 식립된 임플란트의 신뢰성을 향상시키고 수명을 증대시키기 위해서는 가능한 임플란트 주위의 골소실이 일어나지 않도록 해야 할 것이나 골흡수가 일어나 사공간부 수준까지 진행된다면 임플란트의 파절 빈도가 증가될 수 있으므로 이에 대한 대처가 필요할 것으로 사료된다.