• 제목/요약/키워드: test conditions

검색결과 10,967건 처리시간 0.034초

A Study on the Accelerated Life Test for Evaluating the Reliability of Nickel-Cadmium Batteries

  • Kwon, Soo-Ho;Huh, Yang-Hyun;Lim, Tae-Jin
    • International Journal of Reliability and Applications
    • /
    • 제1권1호
    • /
    • pp.89-104
    • /
    • 2000
  • Accelerated testing consists of a variety of test methods for shortening the life of products or hastening the degradation of their performance. This paper presents practical, modern statistical methods for evaluating the reliability of Nickel-Cadmium batteries at their design temperature of 2$0^{\circ}C$ by accelerated life test. Batteries have been life tested at three high temperature conditions, 50, 60, 7$0^{\circ}C$, respectively to yield failures quickly. The failures have been observed and judged by means of charge and discharge current integration. Analyses of life data from those conditions resulted in the Weibull distribution, which has been verified on the ground of the Kolmogorov-smirnov test and the pairwise t-test. Life data are modeled according to the Arrhenius life-temperature relationship. The mean life of tested batteries is assessed at about 590 cycles, and the activation energy of this chemical reaction is concluded to be 0.39eV as results. This study provides procedures for estimating the reliability of batteries in a short period, which has little been possible in domestic industries. The results can be applied in many fields such as proof testing, acceptance testing, and estimating assurance periods.

  • PDF

벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험 (Performance Tests and Development of the Cyclic Load Device Using a Bellows)

  • 최명환;조만순;박승재;김봉구
    • 대한기계학회논문집A
    • /
    • 제31권9호
    • /
    • pp.903-909
    • /
    • 2007
  • A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8mm in diameter and 12.5mm in gage length is also performed under the same conditions as the temperature($550^{\circ}C$) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles(about 12 days), and the displacement in this case is 2.02 mm. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.

일차파괴된 암반사면의 전단강도 및 보강설계법 고찰 (A study on the determination of shear strength and the support design of pre-failed rock slope)

  • 조태진;김영호
    • 터널과지하공간
    • /
    • 제5권2호
    • /
    • pp.104-113
    • /
    • 1995
  • Shear strength of the discontinuity on which the pre-failure of rock slope was occurred during surface excavation was measured through the direct shear test using core samples obtained in-situ. Internal friction angle was increased as the roughness of discontinuity surface(JRC) was increased. Results of the tilt test using core samples of higher JRC also showed very similar trend as those of the direct shear test. When the samples replicated from natural cores were used int he tilt test, results of friction angles showed almost perfect continuation of the residual friction angles from the direct shear test. However, when the gouge material existed in the discontinuity the internal friction angle strongly depended upon the rate of filling thickness to the height of asperity irrespective of the JRC. Based on the results of both direct shear test and tilt test internal friction angle and cohesion of discontinuity, which reflect the in-situ conditions fo pre-sliding failure and also can be used for the optimum design of support system, were assessed. Two kinds of support measures which were expected to increase the stability of rock slope were considered; lowering of slope face angle and installation of rock cable. But, it was found that the first method might lead to more unstable conditions of rock slope when the cohesion of discontinuity plane was negligibly low and in that case the support systems of any kind which could exert actual resisting force were needed to ensure the permanent stability of rock slope.

  • PDF

고밀도 프로빙 테스트를 위한 수직형 프로브카드의 제작 및 특성분석 (Development and Characterization of Vertical Type Probe Card for High Density Probing Test)

  • 민철홍;김태선
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.825-831
    • /
    • 2006
  • As an increase of chip complexity and level of chip integration, chip input/output (I/O) pad pitches are also drastically reduced. With arrival of high complexity SoC (System on Chip) and SiP (System in Package) products, conventional horizontal type probe card showed its limitation on probing density for wafer level test. To enhance probing density, we proposed new vertical type probe card that has the $70{\mu}m$ probe needle with tungsten wire in $80{\mu}m$ micro-drilled hole in ceramic board. To minimize alignment error, micro-drilling conditions are optimized and epoxy-hardening conditions are also optimized to minimize planarity changes. To apply wafer level test for target devices (T5365 256M SDRAM), designed probe card was characterized by probe needle tension for test, contact resistance measurement, leakage current measurement and the planarity test. Compare to conventional probe card with minimum pitch of $50{\sim}125{\mu}m\;and\;2\;{\Omega}$ of average contact resistance, designed probe card showed only $22{\mu}$ of minimum pitch and $1.5{\Omega}$ of average contact resistance. And also, with the nature of vertical probing style, it showed comparably small contact scratch and it can be applied to bumping type chip test.

고온 고압 공기가열기 성능시험 (Performance Test of Vitiated Air Heater with High Temperature and High Pressure)

  • 이정민;나재정;홍윤기;김정우
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.68-75
    • /
    • 2018
  • 본 연구는 설계된 고온 고압 연소식 공기가열기의 성능을 확인하기 위한 성능시험과 그 결과분석에 대한 것이다. 총 4가지의 시험조건에 대한 시험과 3가지 조건에 대한 레이크 측정 시험이 수행되었다. 성능시험결과 목표 온도와 공급 유량조건을 모두 만족하였으며, 최대 공급온도 2000 K, 최대 연소압력 40 bar의 조건을 만족하였다. 공급된 메탄의 유량은 이론값보다 최대 36% 증가하였으며, 측정된 온도는 이론적으로 계산된 온도보다 최대 19.6%의 차이를 보였다.

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • 제35권1호
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.

반복 평판재하시험을 통한 지오그리드 보강지반의 거동 특성 (Behavior of Geogrid-Reinforced Soil with Cyclic plate Load Test)

  • 신은철;김두환;이상조;이규진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.285-292
    • /
    • 1999
  • The cyclic plate load test were peformed to determine the behavior of reinforced soft ground with multiple layers of geogrid. Five series of test were conducted with varying the soil profile conditions which including the ground level, type of soil, and the thickness of each soil layer. The plate load test equipment was slightly modified to apply the cyclic load. Based on the cyclic plate load test results, the bearing capacity ratio(BCR), subbase modules, shear modules, the elastic rebound ratio, and reinforcing parameters are presented.

  • PDF

표준전동차 제동장치에 대한 내구도 평가(I) (Durability evaluation for Korea type EMU's braking system)

  • 정종덕;최병기;한석윤;윤성철;이호용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.131-138
    • /
    • 2001
  • This paper describes the result of endurance test of the brake system of the Korean EMU on the Sangju test track. The purpose of the test is to prove the endurance of brake system. Test conditions are more severe than actual operation on the commercial line. As of October, test result is good without severe problems. 100,000km of test operation will be continued by the end of this year to check the endurance of the brake system.

  • PDF

Test for Parameter Change based on the Estimator Minimizing Density-based Divergence Measures

  • Na, Ok-Young;Lee, Sang-Yeol;Park, Si-Yun
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.287-293
    • /
    • 2003
  • In this paper we consider the problem of parameter change based on the cusum test proposed by Lee et al. (2003). The cusum test statistic is constructed utilizing the estimator minimizing density-based divergence measures. It is shown that under regularity conditions, the test statistic has the limiting distribution of the sup of standard Brownian bridge. Simulation results demonstrate that the cusum test is robust when there arc outliers.

  • PDF

표준전동차 10만km 내구도 시험평가 (An evaluation on 100,000km endurance test for the Korean EMU)

  • 정종덕;김원경;한석윤;이호용;안태기;한성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.336-343
    • /
    • 2002
  • This paper describes the result of endurance test on the Sangju test track. The purpose of the test is to prove the endurance of the Korean EMU for the commercial operation. Test conditions are more severe than actual operation on the commercial line. But endurance test come to an end well without severe problem. Hereafter, Korean EMU will be applied the quality certification of railroad supplies as a testing vehicle and their components will be applied in a new line.

  • PDF