• 제목/요약/키워드: tension tests

검색결과 864건 처리시간 0.032초

점용접 박리-인장 시험편의 후면접촉 영향 (The Effects of Tail Contact for Spot Welding Peel-tension Specimen)

  • 이용복;정진성;박영근;최지훈
    • Journal of Welding and Joining
    • /
    • 제17권4호
    • /
    • pp.69-75
    • /
    • 1999
  • Spot welding has been used in the sheet metal joining processes because of its high productivity and convenience. In this study, predicting methods of fatigue life of spot welded joint have been investigated and fatigue and static tests were conducted with the peel-tension specimens using cold rolled steel plate(SPCC). Fatigue life of peel-tension spot welded joint was influenced by tail effect. Fatigue life evaluation using modified stress index parameter, considering the effective eccentric length, can predict the life more exactly than conventional stress index parameter.

  • PDF

Tension Split Hopkinson bar를 이용한 자동차 성형용 금속 박판의 Johnson-Cook 구성방정식 결정 (Johnson-Cook constitutive relation of sheet metals for an auto-body with a tension split Hopkinson bar apparatus)

  • 강우종;조상순;허훈;정동택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 추계학술대회논문집
    • /
    • pp.84-88
    • /
    • 1997
  • The Jonhnson-Cook constitutive relation has been used in dynamic plasticities. The constants of the Jonhson-Cook relation of sheet metals for an autobody is not known yet. In this paper, the material properties of SPCEN, SPCC and SPRC in the high strain rate states have been acquired. A new tension split Hopkinson bar was used in high speed tensile tests of sheet metals. The experimental results acquired from the apparatus are used to determine the constants of Johnson-Cook constitutive relation of sheet metals. This results can be used to analysis of crashworthness.

  • PDF

초고강도 강섬유 보강 콘크리트의 인장연화거동에 대한 크기효과 (Size Effect for Tension Softening Behavior of Ultra-Strength Steel Fiber Reinforcement Concrete)

  • 이시영;홍기남;김성욱;박정준;한상훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.861-864
    • /
    • 2008
  • This study was performanced to investigate the fractural and fatigue behavior of ultra-strength steel fiber reinforcement concrete. The tension softening diagram can describe the post-cracking behavior of concrete in tension. In this paper, Three points bending tests with a notch have been carried out to investigate tensile properties of the steel fiber reinforced concrete(SFRC) according to variation of the height. Poly-linear approximation method combined with FEM analysis is applied to the steel fiber reinforced concrete to determine the tension softening diagrams and also to certify the validity of the method. The simulated load-CMOD curves using the determined softening diagrams though the poly-linear approximation method completely agree with the measured ones.

  • PDF

초고강도 강섬유 보강 콘크리트의 인장연화 거동 (Tension Softening Behavior of Ultra-Strength Steel Fiber Reinforcement Concrete)

  • 홍기남;한상훈;고경택;박정준;류금성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.417-420
    • /
    • 2006
  • For a better understanding of the fracture behavior of concrete structures, knowledge of the post-cracking behavior of concrete material is essential. The tension softening diagram can describe the post-cracking behavior of concrete in tension. In this paper, Four points bending tests with a notch have been carried out to investigate tensile properties of the steel fiber reinforced concrete(SFRC). Poly-linear approximation method combined with FEM analysis is applied to the steel fiber reinforced concrete to determine the tension softening diagrams and also to certify the validity of the method. The simulated load-CMOD curves using the determined softening diagrams though the poly-linear approximation method completely agree with the measured ones.

  • PDF

Two new relationships for slip velocity and characteristic velocity in a non-center rotating column

  • Torkaman, Rezvan;Heydari, Mehran;Cheshmeh, Javad Najafi;Heydari, Ali;Asadollahzadeh, Mehdi
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2809-2818
    • /
    • 2022
  • In this investigation work, liquid-liquid extraction (L.L.E) through three distinctive frameworks have been examined for assurance of slip velocity (S.V), and characteristic velocity (C.V) in a non-center rotating column (N.C.R.C) with a wide extend of factors. Three double frameworks with distinctive interfacial tension comprising of toluene-water (high interfacial tension), n-butyl acetate-water (medium interfacial tension), and n-butanol-water (low interfacial tension) were investigated for tests. Two common relationships for the expectation of S.V and C.V, including phase stream rates, rotor speed, column geometry additionally physical properties, are displayed. The recommended relationships were compared with test information gotten from the writing and the display examination. Findings of this study, the present proposed correlations are more accurate than those previously reported.

무절점 인장응력 조건의 적용이 가능한 구속형 구조물 균열 거동 대응 성능 시험 장치 개발 (Development of Test Device for Response to Structural Behavior of Constrained that can Apply Zero-Span Tension Conditions)

  • 안현호;최영현;박완구;김영근;오상근;최수영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.214-215
    • /
    • 2021
  • The existing evaluation method could not apply the effect of zero span tension generated in the waterproofing layer attached to the surface of the structure at the moment of cracking as the waterproofing layer was constructed in the state where the cracks were formed. The test apparatus developed through this study is expected to be able to conduct tests closer to the environment occurring in actual structures as it is possible to simultaneously create a pressurized (constrained) condition and an environment for zero span tension.

  • PDF

Tension estimation method using natural frequencies for cable equipped with two dampers

  • Aiko Furukawa;Kenki Goda;Tomohiro Takeichi
    • Structural Monitoring and Maintenance
    • /
    • 제10권4호
    • /
    • pp.361-379
    • /
    • 2023
  • In cable structure maintenance, particularly for cable-stayed bridges, cable safety assessment relies on estimating cable tension. Conventionally, in Japan, cable tension is estimated from the natural frequencies of the cable using the higher-order vibration method. In recent years, dampers have been installed on cables to reduce cable vibrations. Because the higher-order vibration method is a method for damper-free cables, the damper must be removed to measure the natural frequencies of a cable without a damper. However, cables on some cable-stayed bridges have two dampers: one on the girder side and another on the tower side. Notably, removing and reinstalling the damper on the tower side are considerably more time- and labor-intensive. This paper introduces a tension estimation method for cables with two dampers, using natural frequencies. The proposed method was validated through numerical simulation and experiment. In the numerical tests, without measurement error in the natural frequencies, the maximum estimation error among 100 models was 3.3%. With measurement error of 2%, the average estimation error was within 5%, with a maximum error of 9%. The proposed method has high accuracy because the higher-order vibration method for a damper-free cable still has an estimation error of 5%. The experimental verification emphasizes the importance of accurate damper modeling, highlighting potential discrepancies between existing damper design formula and actual damper behavior. By revising the damper formula, the proposed method achieved accurate cable tension estimation, with a maximum estimation error of approximately 10%.

Constitutive model for ratcheting behavior of Z2CND18.12N austenitic stainless steel under non-symmetric cyclic stress based on BP neural network

  • Wang, Xingang;Chen, Xiaohui;Yan, Mingming;Chang, Miaoxin
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.517-525
    • /
    • 2018
  • The specimens made by Z2CND18.12N austenitic stainless steel were conducted on a 100 kN closed loop servo hydraulic tension-compression testing machine with a digital controller. Uniaxial tension and uniaxial ratcheting effect tests were carried out at $25^{\circ}C$. Moreover, Uniaxial tension tests were conducted at $150^{\circ}C$, $250^{\circ}C$ and $350^{\circ}C$. Based on these experimental data, the prediction models of stress-strain curve and the relationship of ratcheting strain and number of cycles were established by the algorithm principle of BP neural network. The results indicated that the predicted results of neural network model were in well agreement with experimental data. It was found that the BP neural network model had high validity and accuracy.

진동법을 이용한 사장교의 시공 중 장력 평가 (Evaluation of Cable Tension Forces Using Vibration Method for a Cable-stayed Bridge under Construction)

  • 조수진;윤정방;심성한
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.38-44
    • /
    • 2014
  • When a cable-stayed bridge is under construction, the cable tension that changes according to the construction phase is the index indicating the proper construction management. In this study, the vibration method using the least-square estimation has been implemented to monitor changing tensions of two multi-strand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea with a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions of two cables are measured before and after the tensioning and 5 days later (i.e., after finishing the tensioning of all cables). The accuracy of the estimated tensions by the vibration method has been improved by employing proper effective lengths of the cables. The measured tensions are compared with the result of the lift-off tests and design tensions. The vibration method shows very good performance in monitoring the changing tensions according to the construction phase with minimal error.

Shear and tensile behaviors of headed stud connectors in double skin composite shear wall

  • Yan, Jia-Bao;Wang, Zhe;Wang, Tao;Wang, Xiao-Ting
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.759-769
    • /
    • 2018
  • This paper studies shear and tensile behaviors of headed stud connectors in double skin composite (DSC) structure. Firstly, 11 push-out tests and 11 tensile tests were performed to investigate the ultimate shear and tensile behaviors of headed stud in DSC shear wall, respectively. The main parameters investigated in this test program were height and layout of headed stud connectors. The test results reported the representative failure modes of headed studs in DSC structures subjected to shear and tension. The shear-slip and tension-elongation behaviors of headed studs in DSC structures were also reported. Influences of different parameters on these shear-slip and tension-elongation behaviors of headed studs were discussed and analyzed. Analytical models were also developed to predict the ultimate shear and tensile resistances of headed stud connectors in DSC shear walls. The developed analytical model incorporated the influence of the dense layout of headed studs in DSC shear walls. The validations of analytical predictions against 22 test results confirmed the accuracy of developed analytical models.