• 제목/요약/키워드: tensile test

검색결과 4,094건 처리시간 0.03초

3D 프린팅을 이용한 PLA+ 소재의 다양한 출력 조건에 따른 인장강도에 대한 연구 (A Study on Tensile Strength According to Various Output Conditions of PLA+ Materials Using 3D Printing)

  • 나두현;김성기
    • 소성∙가공
    • /
    • 제31권2호
    • /
    • pp.89-95
    • /
    • 2022
  • 3D printing products manufactured by material extrusion are used in many industrial fields recently. However, these products are difficult to use in the field due to their low tensile strengths. In order to solve this problem, research on improving the tensile strength of the output using a 3D printer has been continuously conducted. In this study, we performed a tensile test using Universal Testing Machine according to infill pattern, nozzle temperature, bed temperature, and printing speed conditions. Results revealed that tensile specimen of concentric shape had the highest tensile strength in infill pattern condition and that the tensile strength increased linearly with increasing nozzle and bed temperatures. However, the tensile strength decreased with increasing printing speed. Consequently, we confirmed that tensile strength could be increased and decreased depending on output conditions of 3D printing.

Tensile Characteristics and Behavior of Blood Vessels from Human Brain in Uniaxial Tensile Test

  • Suh, Chang-Min;Kim, Sung-Ho;Ken L. Monson;Werner Goldsmith
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1016-1025
    • /
    • 2003
  • The rupture of blood vessels in the human brain results in serious pathological and medical problems. In particular, brain hemorrhage and hematomas resulting from impact to the head are a major cause of death. As such, investigating the tensile behavior and rupture of blood vessels in the brain is very important from a medical point of view. In the present study, the tensile characteristics of the blood vessels in the human brain were analyzed using a quasi-static uniaxial tensile test, and the properties of the arteries and veins compared. In addition, to compare the tensile behavior and demonstrate the validity of the experimental results, blood vessels from the legs of pigs were also tested and analyzed. The overall results were in accordance with the histological structures and previous medical reports.

AC4C 알루미늄 합금의 정적 및 동적 특성 (Static and Dynamic Characteristics of AC4C Aluminum Alloy)

  • 권용구;주원경;송정일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.220-225
    • /
    • 2007
  • The mechanical characteristics of AC4C Aluminum Casting Alloy were investigated by tensile test and impact test. Based on the tensile test' s result, we found that the yield strength of a high speed was about 10% higher than that of a low speed test and the maximum rupture strain mostly occurred in low speed tensile test. The impact energy of curved surface specimen was higher than that of plane surface specimen that can be measured in impact test.

  • PDF

콘크리트 표면처리와 가열조건에 따른 섬유쉬트와 콘크리트의 부착강도에 관한 연구 (A Study on Bond Strength between Fiber Sheet and Concrete for Concrete Surface Preparation and Heating Condition)

  • 안상호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.201-207
    • /
    • 2002
  • An advanced fiber sheet has been widely used for strengthening of the concrete structures due to its excellent properties such as high strength and light weight. Bond strength is very important in strengthening the concrete structures using an advanced fiber sheet. This research examines the bond behavior between fiber sheet and concrete, investigates the bond strength by the direct pull-out test and the tensile-shear test. To obtain the tensile-shear strength a double-face shear type bond test is conducted. The primary test variables are the types of concrete surface roughness (disk-grinding/chipping) and retrofitting methods (bonding/injection). Thirty specimens were tested to evaluate the bond strength. It is shown that the average bond strength between fiber sheet and concrete by the direct pull-out test and the tensile-shear test is $22.3{\sim}23.1kgf/cm^2$ $17.92{\sim}19.75kgf/cm^2$, respectively.

송배전 선로 고장력 인장시험기 개발 (Development of High Tension Tensile Tester for Transmission Line)

  • 신동화;이병호
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.219-225
    • /
    • 2018
  • In this paper, for the testing of tensile strength of dead-end clamp used in transmission line, resulting values were estimated by designing and producing the horizontal version of widely-used vertical tensile tester. Tensile strength test of dead-end clamp for transmission line is essential for quality test of products. Moreover, tensile tester is an equipment that requires high level of reliability which needs to be examined through sampling tests commensurate with total inspection. Frames of tensile tester were made up of H-beams so that it can endure more than 20 [tons] of load capability and the test was implemented for 60[seconds] applying five types of tension. In consequence, the tester could withstand up to 21,600[kg] of weight as well as all types of tension. This newly developed horizontal tensile tester can be utilized in figuring out properties of various materials by estimating tensile strength of materials such as metal, rubber and fiber.

Effects of particle size and loading rate on the tensile failure of asphalt specimens based on a direct tensile test and particle flow code simulation

  • Q. Wang;D.C. Wang;J.W. Fu;Vahab Sarfarazi;Hadi Haeri;C.L. Guo;L.J. Sun;Mohammad Fatehi Marji
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.607-619
    • /
    • 2023
  • This study, it was tried to evaluate the asphalt behavior under tensile loading conditions through indirect Brazilian and direct tensile tests, experimentally and numerically. This paper is important from two points of view. The first one, a new test method was developed for the determination of the direct tensile strength of asphalt and its difference was obtained from the indirect test method. The second one, the effects of particle size and loading rate have been cleared on the tensile fracture mechanism. The experimental direct tensile strength of the asphalt specimens was measured in the laboratory using the compression-to-tensile load converting (CTLC) device. Some special types of asphalt specimens were prepared in the form of slabs with a central hole. The CTLC device is then equipped with this specimen and placed in the universal testing machine. Then, the direct tensile strength of asphalt specimens with different sizes of ingredients can be measured at different loading rates in the laboratory. The particle flow code (PFC) was used to numerically simulate the direct tensile strength test of asphalt samples. This numerical modeling technique is based on the versatile discrete element method (DEM). Three different particle diameters were chosen and were tested under three different loading rates. The results show that when the loading rate was 0.016 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis till coalescence to the model boundary. When the loading rate was 0.032 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis. The branching occurs in these cracks. This shows that the crack propagation is under quasi-static conditions. When the loading rate was 0.064 mm/sec, mixed tensile and shear cracks were initiated below the loading walls and branching occurred in these cracks. This shows that the crack propagation is under dynamic conditions. The loading rate increases and the tensile strength increases. Because all defects mobilized under a low loading rate and this led to decreasing the tensile strength. The experimental results for the direct tensile strengths of asphalt specimens of different ingredients were in good accordance with their corresponding results approximated by DEM software.

시험편 형상에 따른 ETFE 필름재의 인장 특성 (Tensile Characteristics of ETFE Film According to the Specimen Type)

  • 김승덕;주석범;장명호;이정현
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.159-165
    • /
    • 2017
  • In this paper, uniaxial tensile tests of ETFE films with three kinds of thicknesses(100, 200, $250{\mu}m$) and two kinds of directions(machine direction & transverse direction) are performed and the tensile strength, the tensile strain at break and the Young's modulus of ETFE films are compared for two kinds of specimen types(2 & 5). It could be figured out that there are no significant difference between tensile strengths of two specimen types but the tensile strain at break and the Young's modulus of ETFE films are affected by the specimen types. And it is concluded that the uniaxial tensile test of specimen type 2 are more reliable than that of specimen type 5.

Tensile strength of unidirectional CFRP laminate under high strain rate

  • Taniguchi, Norihiko;Nishiwaki, Tsuyoshi;Kawada, Hiroyuki
    • Advanced Composite Materials
    • /
    • 제16권2호
    • /
    • pp.167-180
    • /
    • 2007
  • The tensile strength of unidirectional carbon fiber reinforced plastics under a high strain rate was experimentally investigated. A high-strain-rate test was performed using the tension-type split Hopkinson bar technique. In order to obtain the tensile stress-strain relations, a special fixture was used for the impact tensile specimen. The experimental results demonstrated that the tensile modulus and strength in the longitudinal direction are independent of the strain rate. In contrast, the tensile properties in the transverse direction and the shear properties increase with the strain rate. Moreover, it was observed that the strain-rate dependence of the shear strength is much stronger than that of the transverse strength. The tensile strength of off-axis specimens was measured using an oblique tab, and the experimental results were compared with the tensile strength predicted based on the Tsai-Hill failure criterion. It was concluded that the tensile strength can be characterized quite well using the above failure criterion under dynamic loading conditions.

직접인장 및 간접인장 실험방법에 따른 접착식 콘크리트 덧씌우기의 부착강도 비교 고찰 (Comparative Study on the Bond Strength between Direct Tensile Test and Indirect Tensile Test for Bonded Concrete Overlay)

  • 김영규;이승우
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.1153-1163
    • /
    • 2013
  • 접착식 콘크리트 덧씌우기는 기존 콘크리트 포장과의 재료물성이 유사하여 적절한 유지보수 공법으로 제시되고 있으며, 덧씌우기층과 기존 포장층이 완전부착을 통한 일체화 거동을 하여 우수한 구조적 성능을 확보할 수 있다. 따라서 접착식 콘크리트 덧씌우기의 장기 공용성을 위하여 적절한 부착강도 기준을 확보하는 것이 매우 중요하다. 본 연구에서는 다양한 부착 특성이 부착강도에 미치는 영향을 고찰하고자 하였으며, 덧씌우기 재료, 기존 포장의 압축강도 및 휨강도 변화, 기존 포장의 열화상태 등 다양한 부착조건에 대한 직접인장 및 간접인장 실험을 실시하여 도출되는 부착강도를 비교 분석하고자 하였다. 연구 결과, 직접인장실험에 의한 부착강도가 간접인장실험에 의한 부착강도보다 상대적으로 높게 분포하는 경향을 나타내고 있으나, 결정계수 0.75 및 P-value 0.002의 높은 부착강도 상관관계를 확보하였다. 이를 통하여 접착식 콘크리트 덧씌우기의 실제 현장 거동을 모사할 수 있는 반복하중에 의한 부착 피로 특성 분석 시 직접인장 및 간접인장 실험의 상관관계를 활용할 수 있을 것으로 판단된다.

다짐된 모래-벤토나이트 혼합토의 인장강도 측정 (Tensile Strength Measurement on Compacted Sand-Bentonite Mixtures)

  • 정수정;김태형;김찬기
    • 대한토목학회논문집
    • /
    • 제26권6C호
    • /
    • pp.377-384
    • /
    • 2006
  • 다짐된 모래-벤토나이트 혼합토의 인장강도 측정을 위한 새로운 시험방법을 개발하기 위하여 일축관입(UP)시험에 대한 이론적 실험적 측면에서의 연구를 실시하였다. 다짐된 혼합토의 인장강도는 완전소성이론을 이용한 한계해석으로부터 계산될 수 있으며 개량일축관입시험기(Improved Unconfined Penetration, IUP)는 기존의 일축관입시험기와 비교하여 시험기기의 개선을 통해 측정 오류를 감소시켰다. 선행 시험 결과 원반의 크기와 재하속도의 증가와 pH가 높아(산성)짐에 따라 인장강도가 증가함을 알 수 있었다. 또한 원반 직경이 25.4mm이며 재하속도가 0.5%/min~1%/min일 경우가 개량일축관입시험에 가장 적합하다는 것을 알 수 있었다. 할렬인장시험 결과와의 비교를 통해 개량일축관입시험법의 신뢰성도 확인하였다.