• 제목/요약/키워드: tendon model

검색결과 136건 처리시간 0.024초

Osteogenic Potential of the Periosteum and Periosteal Augmentation for Bone-tunnel Healing

  • Youn Inchan;Suh J-K Francis;Choi Kuiwon
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권2호
    • /
    • pp.101-110
    • /
    • 2005
  • Periosteum and periosteum-derived progenitor cells have demonstrated the potential for stimulative applications in repairs of various musculoskeletal tissues. It has been found that the periosteum contains mesenchymal progenitor cells capable of differentiating into either osteoblasts or chondrocytes depending on the culture conditions. Anatomically, the periosteum is a heterogeneous multi-layered membrane, consisting of an inner cambium and an outer fibrous layer. The present study was designed to elucidate the cellular phenotypic characteristics of cambium and fibrous layer cells in vitro, and to assess whether structural integrity of the tendon in the bone tunnel can be improved by periosteal augmentation of the tendon­bone interface. It was found the cells from each layer showed distinct phenotypic characteristics in a primary monolayer culture system. Specifically, the cambium cells demonstrated higher osteogenic characteristics (higher alkaline phosphatase and osteocalcin levels), as compared to the fibrous cells. Also in vivo animal model showed that a periosteal augmentation of a tendon graft could enhance the structural integrity of the tendon-bone interface, when the periosteum is placed between the tendon and bone interface with the cambium layer facing toward the bone. These findings suggest that extra care needs to be taken in order to identify and maintain the intrinsic phenotypes of the heterogeneous cell types within the periosteum. This will improve our understanding of periosteum in applications for musculoskeletal tissue repairs and tissue engineering.

Modelling of bonded and unbonded post-tensioned concrete flat slabs under flexural and thermal loading

  • Mohammed, Abbas H.;Taysi, Nildem
    • Structural Engineering and Mechanics
    • /
    • 제62권5호
    • /
    • pp.595-606
    • /
    • 2017
  • During their life span, post-tensioned concrete structures may be exposed to thermal loads. Therefore, there has been a growing interest in research on the advanced analysis and design of post-tensioned concrete slabs subjected to thermal loads. This paper investigates the structural behaviour of post-tensioned one-way spanning concrete slabs. A nonlinear finite element model for the analysis of post- tensioned unbonded and bonded concrete slabs at elevated temperatures was developed. The interface between the tendon and surrounding concrete was also modelled, allowing the tendon to retain its profile shape during the deformation of the slab. The load-deflection behaviour, load-force behaviour in the tendon, and the failure modes are presented. The numerical analysis was conducted by the finite element ANSYS software and was carried out on two different one-way concrete slabs chosen from literature. A parametric study was conducted to investigate the effect of several selected parameters on the overall behavior of post-tensioned one-way concrete slab. These parameters include the effect of tendon bonding, the effect of thermal loading and the effect of tendon profile. Comparison between uniform thermal loading and nonuniform thermal loading showed that restrained post tensioned slab with bottom surface hotter has smaller failure load capacity.

정적 인발하중을 받는 암반 앵커의 거동;텐던-그라우트 경계면의 전단응력 분포 (Rock Anchors Subjected to Static Uplift Loads ; Shear Stress Distribution of Tendon-Grout Interface)

  • 임경필;조남준;황성일
    • 한국지반공학회논문집
    • /
    • 제15권6호
    • /
    • pp.143-154
    • /
    • 1999
  • 본 연구에서는 암반 앵커의 텐던-그라우트 경계면의 하중전달기구(load transfer mechanism)를 규명하기 위하여 암질이 강한 자연 화강암과 콘크리트로 제작된 모형 암반에 시공된 모형 암반 앵커에 대한 정적 인발험(static uplift test)을 수행하였다. 불연속면이 텐던-그라우트의 전단응력 분포에 미치는 영향을 밝히기 위하여 수평한 절리면을 갖고 있는 모형암반도 제작되었다. 실험 결과 불연속면이 없는 암반에 시공된 암반 앵커의 경우 앵커 상단에 심한 응력 집중이 발생함을 알 수 있었고 불연속면이 증가할수록 깊이에 따라 균일한 전단응력 분포를 나타냈다. 또한, 실험결과에 대한 회귀분석을 통하여 텐던-그라우트 경계면의 전단응력 분포에 관한 경험식을 산정하였으며, 실험에 의한 전단응력 분포는 텐던 직경의 2~3배 깊이에서는 이론에 의한 전단응력 분포 보다 작게 나타나고 그 이하에서는 반대 현상을 관찰할 수 있었다.

  • PDF

FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가: II. 실험적 검증 및 현장적용 (Evaluation on the Lost Prestressing Force of an External Tendon Using the Combination of FEM and HGA: II. Experimental Verification and Field Applications)

  • 장한백;노명현;박규식;박대효
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권5호통권57호
    • /
    • pp.121-132
    • /
    • 2009
  • 본 논문은 이론으로 개발된 FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가에 대한 실험적 검증과 현장 적용에 대하여 소개한다. 외부 긴장된 텐던에 대한 모형실험과 현장실험을 통하여 진동 실험이 수행되었고, 진동실험으로부터 고유진동수를 획득하였다. 추출된 고유진동수를 기반으로 제안된 기법이 적용되었고, 모형실험으로부터 추정장력과 추정 긴장 손실량은 4%이내의 오차를 보여주었다. 또한 현장실험에서는 Rayleigh 댐핑이 고려된 현장 시스템에 대한 정확한 모델이 모사되었다. 제안된 기법을 적용하여 1%이내의 장력이 추정되었고, 추정된 긴장 손실량은 실제값보다 작은 값으로 수렴되었다.

하지 근골격계질환 평가를 위한 삼차원 근.건모델의 임상적용 (A Clinical Application of 3D Muscle-Tendon Complex Model for the Estimation of Lowerbody Musculoskeletal Disorders)

  • 임용훈;최재일;최안렬;민경기;윤태선;박광용;문정환
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.57-62
    • /
    • 2009
  • Kinematic analysis of MTC (Muscle-Tendon Complex) units is a key indicator for diagnosis of patients with musculoskeletal disorders because the contracture or shortening of musculo-tendinous units is known to produce pathological gaits. Therefore, the principal objective of this study was to assess the length change in the triceps surae prior to and after wearing an AFO (Ankle-Foot Orthoses) in patients with musculoskeletal disorders during a gait. In this study, analyses were conducted using a Muscle Tendon Complex model coupled with the trajectory data from markers attached to anatomical landmarks. As a result, the maximum length change in the triceps surae during a gait was 4.87% when a barefoot walking group and a walking group with AFO were compared. In particular, the difference in length changes between both groups in Soleus MTC units was found to be statistically significant in all gait phases. Our results revealed that MTC length in the AFO walking group was clearly increased over that of the barefoot walking group. In the future, further studies will be required in order to more adequately assess musculoskeletal disorders using many cases studies with regard to agricultural working conditions because this study deals with the kinematic analysis of musculo-tendinous units in the case of clinical experiments.

Development and validation of a computational multibody model of the elbow joint

  • Rahman, Munsur;Cil, Akin;Johnson, Michael;Lu, Yunkai;Guess, Trent M.
    • Advances in biomechanics and applications
    • /
    • 제1권3호
    • /
    • pp.169-185
    • /
    • 2014
  • Computational multibody models of the elbow can provide a versatile tool to study joint mechanics, cartilage loading, ligament function and the effects of joint trauma and orthopaedic repair. An efficiently developed computational model can assist surgeons and other investigators in the design and evaluation of treatments for elbow injuries, and contribute to improvements in patient care. The purpose of this study was to develop an anatomically correct elbow joint model and validate the model against experimental data. The elbow model was constrained by multiple bundles of non-linear ligaments, three-dimensional deformable contacts between articulating geometries, and applied external loads. The developed anatomical computational models of the joint can then be incorporated into neuro-musculoskeletal models within a multibody framework. In the approach presented here, volume images of two cadaver elbows were generated by computed tomography (CT) and one elbow by magnetic resonance imaging (MRI) to construct the three-dimensional bone geometries for the model. The ligaments and triceps tendon were represented with non-linear spring-damper elements as a function of stiffness, ligament length and ligament zero-load length. Articular cartilage was represented as uniform thickness solids that allowed prediction of compliant contact forces. As a final step, the subject specific model was validated by comparing predicted kinematics and triceps tendon forces to experimentally obtained data of the identically loaded cadaver elbow. The maximum root mean square (RMS) error between the predicted and measured kinematics during the complete testing cycle was 4.9 mm medial-lateral translational of the radius relative to the humerus (for Specimen 2 in this study) and 5.30 internal-external rotation of the radius relative to the humerus (for Specimen 3 in this study). The maximum RMS error for triceps tendon force was 7.6 N (for Specimen 3).

Long-term monitoring of ground anchor tensile forces by FBG sensors embedded tendon

  • Sung, Hyun-Jong;Do, Tan Manh;Kim, Jae-Min;Kim, Young-Sang
    • Smart Structures and Systems
    • /
    • 제19권3호
    • /
    • pp.269-277
    • /
    • 2017
  • Recently, there has been significant interest in structural health monitoring for civil engineering applications. In this research, a specially designed tendon, proposed by embedding FBG sensors into the center king cable of a 7-wire strand tendon, was applied for long-term health monitoring of tensile forces on a ground anchor. To make temperature independent sensors, the effective temperature compensation of FBG sensors must be considered. The temperature sensitivity coefficient ${\beta}^{\prime}$ of the FBG sensors embedded tendon was successfully determined to be $2.0{\times}10^{-5}^{\circ}C^{-1}$ through calibrated tests in both a model rock body and a laboratory heat chamber. Furthermore, the obtained result for ${\beta}^{\prime}$ was formally verified through the ground temperature measurement test, expectedly. As a result, the ground temperature measured by a thermometer showed good agreement compared to that measured by the proposed FBG sensor, which was calibrated considering to the temperature sensitivity coefficient ${\beta}^{\prime}$. Finally, four prototype ground anchors including two tension ground anchors and two compression ground anchors made by replacing a tendon with the proposed smart tendon were installed into an actual slope at the Yeosu site. Tensile forces, after temperature compensation was taken into account using the verified temperature sensitivity coefficient ${\beta}^{\prime}$ and ground temperature obtained from the Korean Meteorological Administration (KMA) have been monitored for over one year, and the results were very consistent to those measured from the load cell, interestingly.

FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가: I. 이론 (Evaluation on the Lost Prestressing Force of an External Tendon Using the Combination of FEM and HGA: I. Theory)

  • 박대효;장한택;노명현;박규식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권5호통권57호
    • /
    • pp.109-120
    • /
    • 2009
  • 본 논문은 외부 긴장된 긴장재의 손실 긴장력 추정에 대한 새로운 방법을 소개한다. 제안된 방법은 HGA과 FEM이 조합된 시스템 인식 기법으로 외부긴장된 긴장재의 손실된 긴장력이 추정된다. 제안된 기법의 인식변수로는 외부긴장 긴장재의 긴장력, 유효공칭직경, 단위길이당 질량과 레일리 감쇠 계수가 사용되었다. 첫째로 감쇠의 효과가 적용된 유한요소 모델 시스템을 모형화되고, 시스템 인식변수를 반복적으로 추정하는 역해석 기법을 이용하여 인식하게 된다. 마지막으로 3번의 수치실험을 통하여, 제안기법의 수치적 타당성 여부가 확인된다. 이때, 레일리 감쇠 계수를 제외한 인식변수들의 오차는 1%미만으로 인식된다.

Optimised neural network prediction of interface bond strength for GFRP tendon reinforced cemented soil

  • Zhang, Genbao;Chen, Changfu;Zhang, Yuhao;Zhao, Hongchao;Wang, Yufei;Wang, Xiangyu
    • Geomechanics and Engineering
    • /
    • 제28권6호
    • /
    • pp.599-611
    • /
    • 2022
  • Tendon reinforced cemented soil is applied extensively in foundation stabilisation and improvement, especially in areas with soft clay. To solve the deterioration problem led by steel corrosion, the glass fiber-reinforced polymer (GFRP) tendon is introduced to substitute the traditional steel tendon. The interface bond strength between the cemented soil matrix and GFRP tendon demonstrates the outstanding mechanical property of this composite. However, the lack of research between the influence factors and bond strength hinders the application. To evaluate these factors, back propagation neural network (BPNN) is applied to predict the relationship between them and bond strength. Since adjusting BPNN parameters is time-consuming and laborious, the particle swarm optimisation (PSO) algorithm is proposed. This study evaluated the influence of water content, cement content, curing time, and slip distance on the bond performance of GFRP tendon-reinforced cemented soils (GTRCS). The results showed that the ultimate and residual bond strengths were both in positive proportion to cement content and negative to water content. The sample cured for 28 days with 30% water content and 50% cement content had the largest ultimate strength (3879.40 kPa). The PSO-BPNN model was tuned with 3 neurons in the input layer, 10 in the hidden layer, and 1 in the output layer. It showed outstanding performance on a large database comprising 405 testing results. Its higher correlation coefficient (0.908) and lower root-mean-square error (239.11 kPa) were obtained compared to multiple linear regression (MLR) and logistic regression (LR). In addition, a sensitivity analysis was applied to acquire the ranking of the input variables. The results illustrated that the cement content performed the strongest influence on bond strength, followed by the water content and slip displacement.

텐던 구동 마스터-슬레이브 조작기 최적 정적 출력 되먹임 제어 (Optimal Static Output Feedback Control of Tendon Driven Master-Slave Manipulator)

  • 강민식;이종광;윤지섭;박병석;김기호
    • 제어로봇시스템학회논문지
    • /
    • 제15권10호
    • /
    • pp.1039-1046
    • /
    • 2009
  • In this work, a bilateral control for a master-slave manipulator system which will be used for handling objects contaminated by radioactivity has been addressed. The links of manipulators are driven independently by individual motors installed on the base and the driving torque is transmitted through pre-tensioned tendons. The measurable variables are the positions and rates of master/slave motors. In the consideration of the flexibility of the tendon and available measurements for control, we proposed an optimal static output feedback control for possible bilateral control architecture. By using modal analysis, the system model is reduced to guarantee the detectability which is a necessity for the static output feedback control design. Based on the reduced model, the control gains are determined to attenuate vibration in the sense of optimality. The feasibility of the proposed control design was verified along with some simulation results.