• Title/Summary/Keyword: temporal bright-image sticking

Search Result 6, Processing Time 0.024 seconds

Reduction of the Temporal Bright-Image Sticking in AC-PDP Modules Using the Vacuum Sealing Method

  • Park, Choon-Sang;Cho, Byung-Gwon;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • v.9 no.4
    • /
    • pp.39-44
    • /
    • 2008
  • This paper investigates the effects of the existing sealing methods, such as the conventional atmospheric-pressure sealing method and vacuum sealing, on temporal bright-image sticking. To produce a residual image caused by temporal brightimage sticking, the entire region of a 42-in panel with an Xe-(11%)-He(35%) gas mixture was abruptly changed to a full-white background image after displaying a square-type image at peak luminance for about 60s. From the monitoring of the difference in the display luminance, infrared emission, color temperature, and disappearing time between the cells with and without temporal bright-image sticking, it was observed that the vacuum sealing method contributes to the reduction of temporal bright-image sticking.

Reduction of Temporal Image Sticking in AC Plasma Display Panels through the Use of High He Contents

  • Park, Choon-Sang;Kim, Sun-Ho;Kim, Jae-Hyun;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.195-201
    • /
    • 2009
  • The temporal dark- and bright-image sticking phenomena were examined relative to the He contents under 11% Xe content in the 50-in HD and FHD AC-PDPs with a ternary gas mixture (Xe-He-Ne). To compare the temporal dark- and bright-image sticking phenomena under various He contents, the differences in the disappearing time, display luminance, perceived luminance, infrared emission, color coordinate, color temperature, and discharge current before and after discharge were measured under 0, 35, 50, and 70% He contents. It was found that temporal dark- and bright-image sticking were reduced in proportion to the increase in He %. Thus, a high He content contributes to the reduction of temporal dark- and bright-image sticking.

A study on the temporal bright image sticking problem in AC PDP

  • Ha, Chang-Hoon;Jeong, Dong-Chul;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.113-116
    • /
    • 2004
  • In this study, the causes of temporal bright image sticking problem in an AC PDP were investigated. The temporal bright image sticking problem in an ac PDP is observed to be a relatively lower luminance following several minutes on-time at a high gray level compared to that of the ordinary turned-on image area. We focused on the detailed causes of image sticking, which are directly related with the visible emission such as the changes in the characteristics of phosphor, MgO surface and gas dynamics. The experimental results show that the thermal quenching of phosphor and temperature-dependent discharge characteristics change cause the image sticking problem.

  • PDF

Experimental Study on Reduction of Temporal Dark Image Sticking on Bright Screen in AC-PDPs Using RF-Plasma Treatment on MgO layer

  • Park, Choon-Sang;Kim, Jae-Hyun;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.101-103
    • /
    • 2009
  • Minimizing the residual impurity level on the MgO layer is the key factor for reducing temporal dark image sticking on bright screen. In this paper, to reduce the residual impurity level on the MgO layer of 50-in. full-HD ac-PDP with He (35%) - Xe (11%) contents, RF-plasma treatments on the MgO layer are adopted under various gases for plasma treatment. As a result of monitoring the difference in the display luminance between the before and after 5-min. sustain discharge with a square-type image at peak luminance, the Ar and Ar>$O_2$ plasma treatments can reduce the temporal dark image sticking on the bright screen in an ac-PDP.

  • PDF

Influence of Temporal Dark Image Sticking Characteristics on Bright Screen with Various He contents in 50-in. AC-PDPs

  • Kim, Sun-Ho;Park, Choon-Sang;Kim, Jae-Hyun;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.716-718
    • /
    • 2009
  • The effects of the temporal dark image sticking phenomena on bright screen were investigated with various He, Ne contents and a high Xe content fixed at 11% in the 50-in. ac-PDPs. In this work, the disappearance time and the display luminance between the before and after discharge in the discharge and non-discharge regions were measured with 0%, 35%, and 50% He contents. Consequently, the temporal dark image sticking on bright screen was reduced with the increase of He contents compared with the non-He (0%) content.

  • PDF

Influence of Temporal and Permanent Image Sticking Characteristics Under Variable Panel Working Gas Pressure in 42-in. AC-PDPs

  • Park, Choon-Sang;Jang, Soo-Kwan;Kim, Jae-Hyun;Tae, Heung-Sik;Jung, Eun-Young;Ahn, Jung-Chull;Heo, Eun-Gi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1617-1620
    • /
    • 2008
  • The effects of the temporal and permanent bright image stickings were examined under variable panel working gas pressure in the 42-in. ac-PDP with a high Xe (11 %) content. In the cells with and without temporal and permanent bright image stickings, the display luminance, firing voltage, and Vt closed curve were measured relative to the working gas pressure. With a decrease in the working gas pressure, the temporal bright image sticking was observed to be reduced, whereas the permanent bright image sticking was observed to be deteriorated.

  • PDF