• Title/Summary/Keyword: template

Search Result 2,282, Processing Time 0.032 seconds

Template therapy for mouth opening limitation by temporomandibular joint disorders (턱관절원판 전방 변위로 인한 개구 장애의 템플레이트 치료)

  • Lee, Gi-Cheol;Shin, Seung-Woo;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.270-274
    • /
    • 2010
  • Introduction: Limited mouth opening is a representative clinical symptom of temporomandibular disorders (TMD) with anterior disc displacement without reduction (ADDWOR). Various treatment methods have been proposed for patients with ADDWOR. This study examined the clinical effectiveness of template therapy for patients with mouth opening difficulty due to the ADDWOR. Material and Methods: A total of 14 patients (female 12, male 2, average age: $29.1{\pm}14.4$), who had been treated in the template clinic, Sooncheonhyang University Bucheon Hospital, from January of 2006 to December of 2008, were enrolled in this study. The subjects were selected according to the following criteria: more than 2 weeks after the onset of locking, mouth opening range <35 mm, and confirmed ADDWOR without a synovial pathology by magnetic resonance imaging (MRI). All patients were treated with the template appliance, instructed to wear it while sleeping and exercise for at least 10 hours per day. The maximum mouth opening (MMO) range and pain recognition scores before and after template therapy were recorded and compared. A paired t-test and Wilcoxon's signed rank test were used for statistical analysis. Results: After the periodical follow up, significant improvement in the opening range was observed in the template treatment group. The average MMO range before treatment was $30.2{\pm}3.5mm$ and the average MMO after treatment and follow up was $47.1{\pm}4.7mm$. The mean amount of mouth opening increment was $16.9{\pm}5.4mm$ (P<0.01) and the pain recognition scores before and after treatment was also improved.(P=0.001) Conclusion: The template appliance proved to be efficient for the treatment of TMD with a closed lock and painful joint due to ADDWOR.

A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

  • Youk, Shin-Young;Lee, Jee-Ho;Park, Ji-Man;Heo, Seong-Joo;Roh, Hyun-Ki;Park, Eun-Jin;Shin, Im Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • PURPOSE. This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS. A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computerguided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (${\alpha}=.05$). RESULTS. The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION. In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery.

Anodizing of pure Al foil for AAO as a Nanowire Template (Al 양극산화에 의한 나노선재용 AAO template제조)

  • Lee Kwan Hyi;Lee Hwa Young;Jeung Won Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.2
    • /
    • pp.47-52
    • /
    • 2001
  • AAO template having nano scale pores of high aspect ratio has been prepared through anodizing of aluminum foil in sulfuric acid electrolyte. The effect of anodizing parameters on the pore size and distribution was also examined to obtain the proper AAO as a template material of nanowire. The surface of AAO template prepared was observed by SEM to examine the mean size and distribution of pores generated by the anodizing and Fe nanowires obtained by AC electroforming using AAO template were also observed with TEM to determine the length and shape of them. From the results of work, it was found that the mean size or distribution of pores was influenced significantly by the anodizing parameters such as voltage and temperature of electrolyte. Mean length and aspect ratio of Fe nanowires prepared in the work were found to be $10{\mu}m\;and\;300\;to\;1,000$, respectively.

Removal of Edge Artifact due to Pertial Volume Effect in the Adaptive Template Filtering (적응 템플릿 필터링에서 복셀의 부분 볼륨 효과로 인한 헤지 아티팩트의 제거)

  • 안창범;송영철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.120-127
    • /
    • 2000
  • Adaptive template filtering has been proposed recently for enhancement of signal-to-noise ratio without loss of resolution. In the adaptive template filtering, an optimal template among multiple templates is selected, then linear least square error filtering based on the template is applied in vowel by vowel basis. In some magnetic resonance imaging, where the distribution of gray level has relatively small dynamic range, e.g., $T_1$ imaging, however, artificial stair-like artifact is observed at near edges. This is partially due to the edge enhancement effect in such yokels that contain multiple compounds at the boundaries of tissues. The gray levels of these yokels become similar gray levels of near dominant vowels that contain single compound by the adaptive filtering, which enlarges edge discontinuities. In this paper, we propose a technique to eliminate such artifact by identifying those yokels that contain multiple compounds and assigning the largest template for them. Filtered images with the proposed technique show substantial visual enhancement at the edges without degradation of peak signal-to-noise ratio compared to the original adaptive template filtering for both magnetic resonance images and phantom images.

  • PDF

Scheduling of Workflows under Resource Allocation Constraints using CTR (CTR을 이용한 자윈 할당 제약조건 하에서 워크플로우의 스케줄링)

  • Koh Jae-Jin;An Hyoung-Keun;Lee Dan-Young
    • The KIPS Transactions:PartD
    • /
    • v.13D no.2 s.105
    • /
    • pp.191-198
    • /
    • 2006
  • Many enterprises have introduced workflow to enhance work efficiency and support effective work processes in their various work environments. Recently, Business Process Management(BPM), an extension of workflow, is spotlighted in enterprise software markets Although woklflow plays an important role in Business Process Managements, researches in workflow are mostly concentrated on temporal constraints which finds exact execution sequences for complicated jobs. On that reason, majority of workflow scheduling has concentrated on modeling of various resources which should be handled and the interest for workflow scheduling under constraints related to resources is rather unsatisfactory In this paper we presents the Transformation Template based on Concurrent Transaction Logic(CTR) which is suitable for scheduling workflows with resource allocation constraints, and the logical framework. The Transformation Template consists of a Workflow Transformation Template and a Constraint Transaction Template. Especially the Transformation Template can be conveniently used to logically represent new workflows under the existing resource allocation constraints.

A method to maintain templates in open source-based authoring tool for e-learning assessment items (오픈 소스 기반의 이러닝 평가문항 저작 도구를 위한 템플릿 유지 기법)

  • Han, Sungjae;Choi, Byung-Uk;Cha, Jaehyuk
    • Journal of Digital Contents Society
    • /
    • v.15 no.1
    • /
    • pp.101-112
    • /
    • 2014
  • Existing tools using in the standard e-learning contents authoring were used a method to provide users contents template produced in advance. In order to use resources of the template in a common web-based authoring tool, there is problem to overcome. If the resource of template is inserted within the contents on the authoring tool, the deformation of the template by the user's input that may occur during the edit process cannot be controlled. In this paper, we propose an effective maintenance method to prevent deformation of the resource of template inserted into any WYSIWYG-based HTML authoring tool by user's discretion. We added a template plug-in that can create the IMS-QTI standard resource in tynyMCE the web-based open source editor of representative examples. And the plug-in for tinyMCE was realized as a module of directly respond to the action of limited user input. So, in response to the action of user's input, the structure of the template can be sustained possibly.

Mutual Information-based Circular Template Matching for Image Registration (영상등록을 위한 Mutual Information 기반의 원형 템플릿 정합)

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.547-557
    • /
    • 2014
  • This paper presents a method for designing circular template used in similarity measurement for image registration. Circular template has translation and rotation invariant property, which results in correct matching of control points for image registration under the condition of translation and rotation between reference and sensed images. Circular template consisting of the pixels located on the multiple circumferences of the circles whose radii vary from zero to a certain distance, is converted to two-dimensional Discrete Polar Coordinate Matrix (DPCM), whose elements are the pixels of the circular template. For sensed image, the same type of circular template and DPCM are created by rotating the circular template repeatedly by a certain degree in the range between 0 and 360 degrees and then similarity is calculated using mutual information of the two DPCMs. The best match is determined when the mutual information for each rotation angle at each pixel in search area is maximum. The proposed algorithm was tested using KOMPSAT-2 images acquired at two different times and the results indicate high accurate matching performance under image rotation.

Pt Nanotubes by Template Wetting Process (Template Wetting Process에 의한 Pt 나노튜브 제작)

  • Hwang, J.H.;Yang, B.L.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.1
    • /
    • pp.23-26
    • /
    • 2009
  • Pt nanotubes with diameter of 200 nm were fabricated by simple and convenient method of Template-Wetting Process. Porous alumina membranes were prepared by 2 step anodic oxidation as the template. To improve wetting properties and lower surface energy, pt solution was mixed with polymer. Polymer was removed completely during annealing. Grain growth process of pt nanotubes during baking and furnace annealing was examined by FE-SEM and XRD.

Object Tracking Using CAMshift and Motion Template (컬러 정보와 모션 템플리트를 애용한 객체 추적)

  • Lee, Jin-Hyeong;Kim, Heon-Gi;Kim, Jae-Min;Jo, Seong-Won;Gang, Ji-Un;Jeong, Seon-Tae;Jang, Yong-Seok
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.353-356
    • /
    • 2007
  • 본 논문은 비정형 객체를 추적함에 있어서 다른 객체와 겹쳐진 후 계속 추적할 수 있는 방법을 제시한다. 기본적으로 색 정보 기반의 CAMshift 알고리즘을 바탕으로 각 프레임마다 color template를 업데이트하여 현재의 객체와 template를 비교하고, 업데이트 된 color template를 바탕으로 색 분포를 사용하여 CAMshift 결과를 비교하여 추적하는 물체를 보다 정확하게 판별할 수 있도록 한다.

  • PDF