• Title/Summary/Keyword: temperature zone

Search Result 1,879, Processing Time 0.026 seconds

Physiological Responses of the Human Body on a Change of the Floor Temperature in Indoor (인공기후실내의 바닥온도 변화에 의한 인체의 생리적 반응)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • The purpose of this study is to clarify the floor temperature on the human body and to estimate thermal comfort zone in a heated room. In order to evaluate the effects of floor heating, a series of experiments were carried out using Korean subjects. The following experiments were conducted: 1) to obtain the effective radiation area and configuration factors of the person in the sitting posture on a floor to get the mean radiant temperature, 2) to measure contacted area of the person to the floor to calculate conduction heat rate, 3) to measure convective heat transfer coefficient of the body and 4) to know the thermal comfort zone of indoor environment heated by ON-DOL. Subjects were exposed to the following conditions: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$, $25^{\circ}C$, and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $25^{\circ}C$, $27.5^{\circ}C$, $30^{\circ}C$, $32.5^{\circ}C$, $35^{\circ}C$, $37.5^{\circ}C$, $40^{\circ}C$ under still air and 50% relative humidity in the controllable artificial climate chamber. To evaluate the effect of heat conduction between the body and a floor modified mean skin temperature was defined. Weighting coefficient to calculate mean skin temperature were modified with the contacted area. The experiments revealed a positive correlation between the modified operative temperature and the modified mean skin temperature. The modified mean skin temperature can indicate the effect of heat conduction between body and a floor surface.

  • PDF

Investigation of Microbial Contamination and Working Environment in University Foodservices (대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사)

  • Park, Soon-Hee;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.2
    • /
    • pp.180-191
    • /
    • 2017
  • The purpose of this study was to identity the probability of cross-contamination from the environment. For this, we examined foodservices at 20 universities/colleges for microbiological analysis of their working facilities and environment as well as their preventive equipment against cross-contamination. Seventy percent of the 20 foodservices were found to maintain one unified working area, which suggests high probability of contamination of food/utensils/equipment in the cooking area by pre-preparation or dish washing. According to the microbiological analysis, the hygiene acceptance ratio of working facilities in the clean zone was 70%, which was higher than the average 45% hygiene acceptance ratio of working facilities in the contamination operating zone. There was a significant difference in the total plate count (P<0.001) and coliform count (P<0.01), which demonstrates that work tables in the clean zone were in a good state compared to those in the contamination operating zone. In the contamination operating zone, refrigerator shelves had a high probability of cross-contamination. Regarding the floor surface and airborne microbes, cooking areas which should be maintained as clean zones had higher cross-contamination probability than those in the contamination operating zone. So corrective actions such as cleaning and sanitizing, keeping dry floors, lowered temperature and humidity, shoe disinfecting facilities, and checking concentrations, are necessary to manage floor surfaces and airborne microbes in the cooking area.

Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer (다공층의 증발냉각 열전달에 관한 해석적 연구)

  • 김홍제;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.104-111
    • /
    • 1992
  • In this study, the heat transfer characteristics of the evaporative transpiration cooled system is analytically investigated considering the occurrence of the two-phase evaporation zone. Under the condition of the external heat input, analytical solutions of the three regions (i.e., vapor, liquid and two-phase evaporation zone) are respectively obtained using the matching conditions for the steady-state problem where properties are constant. As results, the length of the evaporation zone increases with increasing heat input and with decreasing mass flow rate. It also increases with increasing particle size, system porosity, thermal conductivity of material, inlet temperature and latent heat of coolant. The position of the lower interface of the evaporation zone have a lot of efforts on the evaporation zone length, the position of the upper interface penetrates deeper into the porous layer with lower thermal conductivity of porous material, higher system porosity and larger particle size.

Effect of Thermal Stratification for Reducing Pressure Rise Rate in HCCI Combustion Based on Multi-zone Modeling (Multi Zone Modeling을 이용한 온도 성층화의 효과를 갖는 예혼합압축자기착화엔진의 압력상승률 저감에 대한 모사)

  • Kwon, O-Seok;Lim, Ock-Taeck
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.32-39
    • /
    • 2009
  • The HCCI engine is a next generation engine, with high efficiency and low emissions. The engine may be an alternative to SI and DI engines; however, HCCI's operating range is limited by an excessive rate of pressure rise during combustion and the resulting engine knock in high-load. The purpose of this study was to gain a understanding of the effect of only initial temperature and thermal stratification for reducing the pressure-rise rate in HCCI combustion. And we confirmed characteristics of combustion, knocking and emissions. The engine was fueled with Di-Methyl Ether. The computations were conducted using both a single-zone model and a multi-zone model by CHEMKIN and modified SENKIN.

Temporal and Spatial Distribution of Benthic Polychaetous Communities in Seomjin River Estuary (섬진강 하구역 저서다모류군집의 시·공간 분포)

  • Kang, Sung Hyo;Lee, Jung Ho;Park, Sung Wan;Shin, Hyun Chool
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.4
    • /
    • pp.243-255
    • /
    • 2014
  • This study was investigated to estimate the relations between benthic environments and benthic polychaetous community from April 2012 to February 2013. Twenty four stations were selected sequentially with Seomjin River Estuary from the northern part of Gwangyang Bay. The study area could be divided into three characteristic zones based on salinity, water temperature, dissolved oxygen and pH such as Saline Water Zone (SWZ), Brackish Water Zone (BWZ), and Fresh Water Zone (FWZ). Salinity was above 30.0 psu in SWZ, drastically decreased toward inland in BWZ, and nearly zero psu in FWZ. SWZ showed its specific environmental characters like that water temperature fluctuated with little seasonal change and DO showed the lowest values among three zones, and pH maintained as consistent value without seasonal fluctuation. In FWZ, on the other hand, water temperature showed high seasonal fluctuation, DO showed the highest values among three zones, and pH fluctuated greatly. In sedimentary environment, mud, sand and sand/gravel were found as dominant sedimentary deposits in SWZ, BWZ and FWZ, respectively. Organic matter content and AVS in surface sediment were high in SWZ, while Chl-a content high in FWZ. This study area showed a marked environmental difference between FWZ and SWZ as follows: FWZ has coarse sediment and low salinity, low organic matter content, low AVS in FWZ but SWZ has fine sediment and high salinity, high organic matter content and AVS. Species number and mean density of benthic polychaete community was highest in Saline Water Zone (SWZ), drastically decreased in Brackish Water Zone (BWZ), and lowest in Fresh Water Zone (FWZ). Dominant polychates above 5.0% of individual numbers were 6 taxa. Lumbrineris longifolia, Prionospio cirrifera, Tharyx sp. occurred as main dominant species of all study periods, and Hediste sp., Praxillella affinis, Tylorrhynchus sp. dominantly occurred at some seasons. Inhabiting areas of dominant species were separated characteristically. Representative species in SWZ were Lumbrineris longifolia, Tharyx sp., Mediomastus sp.. Wide-appearing species between SWZ and BWZ were Prionospio cirrifera, Heteromastus filiformis, Aricidea sp.. Characteristic species in FWZ were Tylorrhynchus sp. and Hediste sp.. As the results of cluster analysis and nMDS based on the species composition of polychaetous community, unique station groups were established in SWZ and FWZ. Stations in BWZ were sub-divided into several groups with season. Pearson's correlation analysis and PCA between benthic environments and ecological characteristics of polychaetous community showed that salinity, sediment composition, organic content and dissolved oxygen played a role to determine the temporal and spatial distribution of the ecological characteristics as species number, mean density, abundance of main species, and ecological indices.

Microstuctures and Themal Stability of Rapidly Solidified Al-Fe-V-Si-(Mn) Alloys (급랭응고한 Al-Fe-V-Si계 합금의 미세조직과 열안정성에 관한 연구)

  • Kim, Seon-Hwa;Park, Won-Wook
    • Applied Microscopy
    • /
    • v.21 no.2
    • /
    • pp.57-66
    • /
    • 1991
  • The main purpose of this paper was to investigate the change of rapidly solidified microstructures and dispersoid behavior according to heat-treatment in the Al-Fe-V-Si-(Mn) alloys. It was found that (111) preferred orientation identified by X-ray diffraction and fine subgrain/large grain were observed in the rapidly solidified Al-Fe-V-Si-(Mn) alloys. Cell boundary of the zone A was composed of the microcrystalline, whereas that of the zone B was amorphous. Decomposition of the Al-Fe-V-Si-(Mn) alloys occurred at about $300^{\circ}C$. These alloys exhibited excellent thermal stability at the elevated temperature. Microstructure of the zone B was more stable than that of the zone A. The spherical dispersoid and 5-fold symmetry phase was also more thermally stable than the amorphous structure of cell boundary.

  • PDF

Analysis on Heat Supply Piping Network for Apartment House (아파트의 온수공급배관망해석)

  • 박윤철;황광일
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

Numerical Analysis for Residual Stress Relaxation of Weld Zone (용접부 잔류응력의 이완에 관한 해석)

  • Seo, Jung-Won;Goo, Byung-Chun;Lee, Dong-Hyeong;Jung, Hong-Che
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.43-48
    • /
    • 2003
  • The problem of welding stresses and fatigue behavior is the main concerns of welding research fields. The residual stresses and distortion of structures by welding is exert negative effect on the safety of mechanical structures. That is, expansion of material by high temperature and distortion by cooling during welding process is caused of tensile and compressive residual stresses on welding material, and this residual stresses reduce fracture and fatigue strength of welding structures. The accurate prediction of residual stress and relaxation due to loading and post weld heat treatment of weld zone is very important to improve the quality of weldment. In this study, a finite element modeling technique is developed to simulate the relaxation of residual stresses due to loading and post weld heat treatment of weld zone. The accuracy of finite element models is evaluated based on experimental results and the results of the analytical solution.

  • PDF

Warming Trend of Coastal Waters of Korea during Recent 60 Years (1936-1995)

  • Kang Yong Q.
    • Fisheries and Aquatic Sciences
    • /
    • v.3 no.3_4
    • /
    • pp.173-179
    • /
    • 2000
  • Recent changes in the coastal sea surface temperatures (SST) in Korea are studied by time series analysis of daily SST data during the last 60 years (1936-1995) at 18 coastal observation stations of the National Fisheries Research and Development Institute. The climate of coastal SST in Korea are rapidly changing in recent years. General trends of coast SST changes in Korea are as follows. The annual averages of SST are increasing. The annual ranges of SST variation are decreasing. The winter SST are increasing while the summer SST have a decreasing tendency. Climatic changes in coastal SST in recent 30 years (1965-1995) are more pronounced than those in the last 60 years (1936-1995). The observed trend of coast SST implies that the climate in Korea shows a tendency to shift from temperate zone to subtropical zone.

  • PDF